cve,link,title,description,vendor,products,score,severity,epss,cisa,cisa_published,article,ransomware,exploited,poc,trended,trended_no_1,published,trended_score CVE-2023-37194,https://securityvulnerability.io/vulnerability/CVE-2023-37194,Code Execution Vulnerability in Siemens SIMATIC Devices,"A significant vulnerability has been discovered in various Siemens SIMATIC devices, which exposes the kernel memory to user-mode through direct memory access (DMA). This exposure allows an attacker with administrative privileges to potentially execute arbitrary code on the host system. This poses a serious risk as it could lead to unauthorized system control and compromise the integrity of the device.",Siemens,"Simatic Cp 1604,Simatic Cp 1616,Simatic Cp 1623,Simatic Cp 1626,Simatic Cp 1628",6.7,MEDIUM,0.0006000000284984708,false,,false,false,false,,false,false,2023-10-10T11:15:00.000Z,0 CVE-2023-37195,https://securityvulnerability.io/vulnerability/CVE-2023-37195,Buffer Overflow Vulnerability in SIMATIC CP Devices by Siemens,"A vulnerability has been detected in various Siemens SIMATIC CP devices due to inadequate control over direct memory access (DMA) requests. This flaw can be exploited by local attackers with administrative access, potentially leading to a denial of service condition that disrupts operations. Recovery from this state necessitates a physical power cycle, affecting system availability and reliability.",Siemens,"Simatic Cp 1604,Simatic Cp 1616,Simatic Cp 1623,Simatic Cp 1626,Simatic Cp 1628",4.4,MEDIUM,0.0004199999966658652,false,,false,false,false,,false,false,2023-10-10T11:15:00.000Z,0 CVE-2020-28400,https://securityvulnerability.io/vulnerability/CVE-2020-28400,,Affected devices contain a vulnerability that allows an unauthenticated attacker to trigger a denial of service condition. The vulnerability can be triggered if a large amount of DCP reset packets are sent to the device.,Siemens,"Development/evaluation Kits For Profinet Io: Dk Standard Ethernet Controller,Development/evaluation Kits For Profinet Io: Ek-ertec 200,Development/evaluation Kits For Profinet Io: Ek-ertec 200p,Ruggedcom Rm1224 Lte(4g) Eu,Ruggedcom Rm1224 Lte(4g) Nam,Scalance M804pb,Scalance M812-1 Adsl-router,Scalance M816-1 Adsl-router,Scalance M826-2 Shdsl-router,Scalance M874-2,Scalance M874-3,Scalance M874-3 3g-router (cn),Scalance M876-3,Scalance M876-3 (rok),Scalance M876-4,Scalance M876-4 (eu),Scalance M876-4 (nam),Scalance Mum853-1 (a1),Scalance Mum853-1 (b1),Scalance Mum853-1 (eu),Scalance Mum856-1 (a1),Scalance Mum856-1 (b1),Scalance Mum856-1 (cn),Scalance Mum856-1 (eu),Scalance Mum856-1 (row),Scalance S615 Eec Lan-router,Scalance S615 Lan-router,Scalance W1748-1 M12,Scalance W1788-1 M12,Scalance W1788-2 Eec M12,Scalance W1788-2 M12,Scalance W1788-2ia M12,Scalance W721-1 Rj45,Scalance W722-1 Rj45,Scalance W734-1 Rj45,Scalance W734-1 Rj45 (usa),Scalance W738-1 M12,Scalance W748-1 M12,Scalance W748-1 Rj45,Scalance W761-1 Rj45,Scalance W774-1 M12 Eec,Scalance W774-1 Rj45,Scalance W774-1 Rj45 (usa),Scalance W778-1 M12,Scalance W778-1 M12 Eec,Scalance W778-1 M12 Eec (usa),Scalance W786-1 Rj45,Scalance W786-2 Rj45,Scalance W786-2 Sfp,Scalance W786-2ia Rj45,Scalance W788-1 M12,Scalance W788-1 Rj45,Scalance W788-2 M12,Scalance W788-2 M12 Eec,Scalance W788-2 Rj45,Scalance X200-4p Irt,Scalance X201-3p Irt,Scalance X201-3p Irt Pro,Scalance X202-2irt,Scalance X202-2p Irt,Scalance X202-2p Irt Pro,Scalance X204-2,Scalance X204-2fm,Scalance X204-2ld,Scalance X204-2ld Ts,Scalance X204-2ts,Scalance X204irt,Scalance X204irt Pro,Scalance X206-1,Scalance X206-1ld,Scalance X208,Scalance X208pro,Scalance X212-2,Scalance X212-2ld,Scalance X216,Scalance X224,Scalance X302-7 Eec (230v, Coated),Scalance X302-7 Eec (230v),Scalance X302-7 Eec (24v, Coated),Scalance X302-7 Eec (24v),Scalance X302-7 Eec (2x 230v, Coated),Scalance X302-7 Eec (2x 230v),Scalance X302-7 Eec (2x 24v, Coated),Scalance X302-7 Eec (2x 24v),Scalance X304-2fe,Scalance X306-1ld Fe,Scalance X307-2 Eec (230v, Coated),Scalance X307-2 Eec (230v),Scalance X307-2 Eec (24v, Coated),Scalance X307-2 Eec (24v),Scalance X307-2 Eec (2x 230v, Coated),Scalance X307-2 Eec (2x 230v),Scalance X307-2 Eec (2x 24v, Coated),Scalance X307-2 Eec (2x 24v),Scalance X307-3,Scalance X307-3ld,Scalance X308-2,Scalance X308-2ld,Scalance X308-2lh,Scalance X308-2lh+,Scalance X308-2m,Scalance X308-2m Poe,Scalance X308-2m Ts,Scalance X310,Scalance X310fe,Scalance X320-1 Fe,Scalance X320-1-2ld Fe,Scalance X408-2,Scalance Xb205-3 (sc, Pn),Scalance Xb205-3 (st, E/ip),Scalance Xb205-3 (st, Pn),Scalance Xb205-3ld (sc, E/ip),Scalance Xb205-3ld (sc, Pn),Scalance Xb208 (e/ip),Scalance Xb208 (pn),Scalance Xb213-3 (sc, E/ip),Scalance Xb213-3 (sc, Pn),Scalance Xb213-3 (st, E/ip),Scalance Xb213-3 (st, Pn),Scalance Xb213-3ld (sc, E/ip),Scalance Xb213-3ld (sc, Pn),Scalance Xb216 (e/ip),Scalance Xb216 (pn),Scalance Xc206-2 (sc),Scalance Xc206-2 (st/bfoc),Scalance Xc206-2g Poe,Scalance Xc206-2g Poe (54 V Dc),Scalance Xc206-2g Poe Eec (54 V Dc),Scalance Xc206-2sfp,Scalance Xc206-2sfp Eec,Scalance Xc206-2sfp G,Scalance Xc206-2sfp G (eip Def.),Scalance Xc206-2sfp G Eec,Scalance Xc208,Scalance Xc208eec,Scalance Xc208g,Scalance Xc208g (eip Def.),Scalance Xc208g Eec,Scalance Xc208g Poe,Scalance Xc208g Poe (54 V Dc),Scalance Xc216,Scalance Xc216-3g Poe,Scalance Xc216-3g Poe (54 V Dc),Scalance Xc216-4c,Scalance Xc216-4c G,Scalance Xc216-4c G (eip Def.),Scalance Xc216-4c G Eec,Scalance Xc216eec,Scalance Xc224,Scalance Xc224-4c G,Scalance Xc224-4c G (eip Def.),Scalance Xc224-4c G Eec,Scalance Xf201-3p Irt,Scalance Xf202-2p Irt,Scalance Xf204,Scalance Xf204 Dna,Scalance Xf204-2,Scalance Xf204-2ba,Scalance Xf204-2ba Dna,Scalance Xf204-2ba Irt,Scalance Xf204irt,Scalance Xf206-1,Scalance Xf208,Scalance Xm408-4c,Scalance Xm408-4c (l3 Int.),Scalance Xm408-8c,Scalance Xm408-8c (l3 Int.),Scalance Xm416-4c,Scalance Xm416-4c (l3 Int.),Scalance Xp208,Scalance Xp208 (ethernet/ip),Scalance Xp208eec,Scalance Xp208poe Eec,Scalance Xp216,Scalance Xp216 (ethernet/ip),Scalance Xp216eec,Scalance Xp216poe Eec,Scalance Xr324-12m (230v, Ports On Front),Scalance Xr324-12m (230v, Ports On Rear),Scalance Xr324-12m (24v, Ports On Front),Scalance Xr324-12m (24v, Ports On Rear),Scalance Xr324-12m Ts (24v),Scalance Xr324-4m Eec (100-240vac/60-250vdc, Ports On Front),Scalance Xr324-4m Eec (100-240vac/60-250vdc, Ports On Rear),Scalance Xr324-4m Eec (24v, Ports On Front),Scalance Xr324-4m Eec (24v, Ports On Rear),Scalance Xr324-4m Eec (2x 100-240vac/60-250vdc, Ports On Front),Scalance Xr324-4m Eec (2x 100-240vac/60-250vdc, Ports On Rear),Scalance Xr324-4m Eec (2x 24v, Ports On Front),Scalance Xr324-4m Eec (2x 24v, Ports On Rear),Scalance Xr324-4m Poe (230v, Ports On Front),Scalance Xr324-4m Poe (230v, Ports On Rear),Scalance Xr324-4m Poe (24v, Ports On Front),Scalance Xr324-4m Poe (24v, Ports On Rear),Scalance Xr324-4m Poe Ts (24v, Ports On Front),Scalance Xr324wg (24 X Fe, Ac 230v),Scalance Xr324wg (24 X Fe, Dc 24v),Scalance Xr326-2c Poe Wg,Scalance Xr326-2c Poe Wg (without Ul),Scalance Xr328-4c Wg (24xfe, 4xge, 24v),Scalance Xr328-4c Wg (24xfe, 4xge,dc24v),Scalance Xr328-4c Wg (24xfe,4xge,ac230v),Scalance Xr328-4c Wg (28xge, Ac 230v),Scalance Xr328-4c Wg (28xge, Dc 24v),Scalance Xr524-8c, 1x230v,Scalance Xr524-8c, 1x230v (l3 Int.),Scalance Xr524-8c, 24v,Scalance Xr524-8c, 24v (l3 Int.),Scalance Xr524-8c, 2x230v,Scalance Xr524-8c, 2x230v (l3 Int.),Scalance Xr526-8c, 1x230v,Scalance Xr526-8c, 1x230v (l3 Int.),Scalance Xr526-8c, 24v,Scalance Xr526-8c, 24v (l3 Int.),Scalance Xr526-8c, 2x230v,Scalance Xr526-8c, 2x230v (l3 Int.),Scalance Xr528-6m,Scalance Xr528-6m (2hr2, L3 Int.),Scalance Xr528-6m (2hr2),Scalance Xr528-6m (l3 Int.),Scalance Xr552-12m,Scalance Xr552-12m (2hr2, L3 Int.),Scalance Xr552-12m (2hr2),Simatic Cfu Diq,Simatic Cfu Pa,Simatic Cm 1542-1,Simatic Cp 1604,Simatic Cp 1616,Simatic Cp 1626,Simatic Ie/pb-link,Simatic Mv540 H,Simatic Mv540 S,Simatic Mv550 H,Simatic Mv550 S,Simatic Mv560 U,Simatic Mv560 X,Simatic Net Dk-16xx Pn Io,Simatic Power Line Booster Plb, Base Module,Simatic Profinet Driver,Simatic S7-1200 Cpu Family (incl. Siplus Variants),Simocode Pro V Ethernet/ip (incl. Siplus Variants),Simocode Pro V Profinet (incl. Siplus Variants),Siplus Net Scalance X308-2,Siplus Net Scalance Xc206-2,Siplus Net Scalance Xc206-2sfp,Siplus Net Scalance Xc208,Siplus Net Scalance Xc216-4c,Softnet-ie Pnio",7.5,HIGH,0.002850000048056245,false,,false,false,false,,false,false,2021-07-13T11:02:49.000Z,0 CVE-2019-13946,https://securityvulnerability.io/vulnerability/CVE-2019-13946,,"Profinet-IO (PNIO) stack versions prior V06.00 do not properly limit internal resource allocation when multiple legitimate diagnostic package requests are sent to the DCE-RPC interface. This could lead to a denial of service condition due to lack of memory for devices that include a vulnerable version of the stack. The security vulnerability could be exploited by an attacker with network access to an affected device. Successful exploitation requires no system privileges and no user interaction. An attacker could use the vulnerability to compromise the availability of the device.",Siemens,"Development/evaluation Kits For Profinet Io: Dk Standard Ethernet Controller,Development/evaluation Kits For Profinet Io: Ek-ertec 200,Development/evaluation Kits For Profinet Io: Ek-ertec 200p,Profinet Driver For Controller,Ruggedcom Rm1224 Family,Scalance M804pb,Scalance M812-1 Adsl-router,Scalance M816-1 Adsl-router,Scalance M826-2 Shdsl-router,Scalance M874-2,Scalance M874-3,Scalance M876-3,Scalance M876-3 (rok),Scalance M876-4 (eu),Scalance M876-4 (nam),Scalance S615 Lan-router,Scalance W-700 Ieee 802.11n Family,Scalance X200-4p Irt,Scalance X201-3p Irt,Scalance X201-3p Irt Pro,Scalance X202-2irt,Scalance X202-2p Irt,Scalance X202-2p Irt Pro,Scalance X204-2,Scalance X204-2fm,Scalance X204-2ld,Scalance X204-2ld Ts,Scalance X204-2ts,Scalance X204irt,Scalance X204irt Pro,Scalance X206-1,Scalance X206-1ld,Scalance X208,Scalance X208pro,Scalance X212-2,Scalance X212-2ld,Scalance X216,Scalance X224,Scalance X302-7 Eec (230v, Coated),Scalance X302-7 Eec (230v),Scalance X302-7 Eec (24v, Coated),Scalance X302-7 Eec (24v),Scalance X302-7 Eec (2x 230v, Coated),Scalance X302-7 Eec (2x 230v),Scalance X302-7 Eec (2x 24v, Coated),Scalance X302-7 Eec (2x 24v),Scalance X304-2fe,Scalance X306-1ld Fe,Scalance X307-2 Eec (230v, Coated),Scalance X307-2 Eec (230v),Scalance X307-2 Eec (24v, Coated),Scalance X307-2 Eec (24v),Scalance X307-2 Eec (2x 230v, Coated),Scalance X307-2 Eec (2x 230v),Scalance X307-2 Eec (2x 24v, Coated),Scalance X307-2 Eec (2x 24v),Scalance X307-3,Scalance X307-3ld,Scalance X308-2,Scalance X308-2ld,Scalance X308-2lh,Scalance X308-2lh+,Scalance X308-2m,Scalance X308-2m Poe,Scalance X308-2m Ts,Scalance X310,Scalance X310fe,Scalance X320-1 Fe,Scalance X320-1-2ld Fe,Scalance X408-2,Scalance Xb-200 Family,Scalance Xc-200,Scalance Xf-200ba,Scalance Xf201-3p Irt,Scalance Xf202-2p Irt,Scalance Xf204,Scalance Xf204-2,Scalance Xf204-2ba Irt,Scalance Xf204irt,Scalance Xf206-1,Scalance Xf208,Scalance Xm-400 Family,Scalance Xp-200,Scalance Xr-300wg Family,Scalance Xr-500 Family,Scalance Xr324-12m (230v, Ports On Front),Scalance Xr324-12m (230v, Ports On Rear),Scalance Xr324-12m (24v, Ports On Front),Scalance Xr324-12m (24v, Ports On Rear),Scalance Xr324-12m Ts (24v),Scalance Xr324-4m Eec (100-240vac/60-250vdc, Ports On Front),Scalance Xr324-4m Eec (100-240vac/60-250vdc, Ports On Rear),Scalance Xr324-4m Eec (24v, Ports On Front),Scalance Xr324-4m Eec (24v, Ports On Rear),Scalance Xr324-4m Eec (2x 100-240vac/60-250vdc, Ports On Front),Scalance Xr324-4m Eec (2x 100-240vac/60-250vdc, Ports On Rear),Scalance Xr324-4m Eec (2x 24v, Ports On Front),Scalance Xr324-4m Eec (2x 24v, Ports On Rear),Scalance Xr324-4m Poe (230v, Ports On Front),Scalance Xr324-4m Poe (230v, Ports On Rear),Scalance Xr324-4m Poe (24v, Ports On Front),Scalance Xr324-4m Poe (24v, Ports On Rear),Scalance Xr324-4m Poe Ts (24v, Ports On Front),Simatic Cp 1616 And Cp 1604,Simatic Cp 343-1,Simatic Cp 343-1 Advanced,Simatic Cp 343-1 Erpc,Simatic Cp 343-1 Lean,Simatic Cp 443-1,Simatic Cp 443-1 Advanced,Simatic Cp 443-1 Opc Ua,Simatic Et 200al Im 157-1 Pn,Simatic Et 200m Im 153-4 Pn Io Hf (incl. Siplus Variants),Simatic Et 200m Im 153-4 Pn Io St (incl. Siplus Variants),Simatic Et 200mp Im 155-5 Pn Hf,Simatic Et 200mp Im 155-5 Pn St,Simatic Et 200pro Im 154-3 Pn Hf,Simatic Et 200pro Im 154-4 Pn Hf,Simatic Et 200sp Im 155-6 Pn Ba,Simatic Et 200sp Im 155-6 Pn Hf,Simatic Et 200sp Im 155-6 Pn St,Simatic Et 200sp Im 155-6 Pn St Ba,Simatic Et200ecopn, 16di, Dc24v, 8xm12,Simatic Et200ecopn, 16do Dc24v/1,3a, 8xm12,Simatic Et200ecopn, 4ao U/i 4xm12,Simatic Et200ecopn, 8 Dio, Dc24v/1,3a, 8xm12,Simatic Et200ecopn, 8 Do, Dc24v/2a, 8xm12,Simatic Et200ecopn, 8ai Rtd/tc 8xm12,Simatic Et200ecopn, 8ai; 4 U/i; 4 Rtd/tc 8xm12,Simatic Et200ecopn, 8di, Dc24v, 4xm12,Simatic Et200ecopn, 8di, Dc24v, 8xm12,Simatic Et200ecopn, 8do, Dc24v/0,5a, 4xm12,Simatic Et200ecopn, 8do, Dc24v/1,3a, 4xm12,Simatic Et200ecopn, 8do, Dc24v/1,3a, 8xm12,Simatic Et200ecopn: Io-link Master,Simatic Et200s (incl. Siplus Variants),Simatic Ipc Support, Package For Vxworks,Simatic Mv420 Sr-b,Simatic Mv420 Sr-b Body,Simatic Mv420 Sr-p,Simatic Mv420 Sr-p Body,Simatic Mv440 Hr,Simatic Mv440 Sr,Simatic Mv440 Ur,Simatic Pn/pn Coupler (incl. Siplus Net Variants),Simatic Rf180c,Simatic Rf182c,Simatic Rf600r Family,Simotion C,Simotion D,Simotion P,Sinamics Dcp,Siplus Et 200mp Im 155-5 Pn Hf,Siplus Et 200mp Im 155-5 Pn Hf T1 Rail,Siplus Et 200mp Im 155-5 Pn St,Siplus Et 200mp Im 155-5 Pn St Tx Rail,Siplus Et 200sp Im 155-6 Pn Hf,Siplus Et 200sp Im 155-6 Pn Hf T1 Rail,Siplus Et 200sp Im 155-6 Pn St,Siplus Et 200sp Im 155-6 Pn St Ba,Siplus Et 200sp Im 155-6 Pn St Ba Tx Rail,Siplus Et 200sp Im 155-6 Pn St Tx Rail,Siplus Net Cp 343-1,Siplus Net Cp 343-1 Advanced,Siplus Net Cp 343-1 Lean,Siplus Net Cp 443-1,Siplus Net Cp 443-1 Advanced,Siplus Net Scalance X308-2,Softnet-ie Pnio",7.5,HIGH,0.0012000000569969416,false,,false,false,false,,false,false,2020-02-11T15:36:10.000Z,0 CVE-2019-10923,https://securityvulnerability.io/vulnerability/CVE-2019-10923,,An attacker with network access to an affected product may cause a denial of service condition by breaking the real-time synchronization (IRT) of the affected installation.,Siemens,"Development/evaluation Kits For Profinet Io: Dk Standard Ethernet Controller,Development/evaluation Kits For Profinet Io: Ek-ertec 200,Development/evaluation Kits For Profinet Io: Ek-ertec 200p,Scalance X-200irt Family (incl. Siplus Net Variants),Simatic Et 200m (incl. Siplus Variants),Simatic Et 200mp Im 155-5 Pn Hf,Simatic Et 200mp Im 155-5 Pn St,Simatic Et 200pro Im 154-3 Pn Hf,Simatic Et 200pro Im 154-4 Pn Hf,Simatic Et 200pro Im 154-8 Pn/dp Cpu,Simatic Et 200pro Im 154-8f Pn/dp Cpu,Simatic Et 200pro Im 154-8fx Pn/dp Cpu,Simatic Et 200s Im 151-8 Pn/dp Cpu,Simatic Et 200s Im 151-8f Pn/dp Cpu,Simatic Et 200sp Im 155-6 Pn Hf,Simatic Et 200sp Im 155-6 Pn St,Simatic Et 200sp Im 155-6 Pn St Ba,Simatic Et200ecopn, 16di, Dc24v, 8xm12,Simatic Et200ecopn, 16do Dc24v/1,3a, 8xm12,Simatic Et200ecopn, 4ao U/i 4xm12,Simatic Et200ecopn, 8 Dio, Dc24v/1,3a, 8xm12,Simatic Et200ecopn, 8 Do, Dc24v/2a, 8xm12,Simatic Et200ecopn, 8ai Rtd/tc 8xm12,Simatic Et200ecopn, 8ai; 4 U/i; 4 Rtd/tc 8xm12,Simatic Et200ecopn, 8di, Dc24v, 4xm12,Simatic Et200ecopn, 8di, Dc24v, 8xm12,Simatic Et200ecopn, 8do, Dc24v/0,5a, 4xm12,Simatic Et200ecopn, 8do, Dc24v/1,3a, 4xm12,Simatic Et200ecopn, 8do, Dc24v/1,3a, 8xm12,Simatic Et200ecopn: Io-link Master,Simatic Et200s (incl. Siplus Variants),Simatic Net Cp 1604,Simatic Net Cp 1616,Simatic Pn/pn Coupler (incl. Siplus Net Variants),Simatic S7-300 Cpu 314c-2 Pn/dp,Simatic S7-300 Cpu 315-2 Pn/dp,Simatic S7-300 Cpu 315f-2 Pn/dp,Simatic S7-300 Cpu 315t-3 Pn/dp,Simatic S7-300 Cpu 317-2 Pn/dp,Simatic S7-300 Cpu 317f-2 Pn/dp,Simatic S7-300 Cpu 317t-3 Pn/dp,Simatic S7-300 Cpu 317tf-3 Pn/dp,Simatic S7-300 Cpu 319-3 Pn/dp,Simatic S7-300 Cpu 319f-3 Pn/dp,Simatic S7-400 Cpu 412-2 Pn V7,Simatic S7-400 Cpu 414-3 Pn/dp V7,Simatic S7-400 Cpu 414f-3 Pn/dp V7,Simatic S7-400 Cpu 416-3 Pn/dp V7,Simatic S7-400 Cpu 416f-3 Pn/dp V7,Simatic S7-400 Pn/dp V6 And Below Cpu Family (incl. Siplus Variants),Simatic Winac Rtx 2010,Simatic Winac Rtx F 2010,Simotion,Sinamics Dcm,Sinamics Dcp,Sinamics G110m V4.7 Control Unit,Sinamics G120 V4.7 Control Unit (incl. Siplus Variants),Sinamics G130 V4.7 Control Unit,Sinamics G150 Control Unit,Sinamics Gh150 V4.7 Control Unit,Sinamics Gl150 V4.7 Control Unit,Sinamics Gm150 V4.7 Control Unit,Sinamics S110 Control Unit,Sinamics S120 V4.7 Control Unit And Cbe20 (incl. Siplus Variants),Sinamics S150 Control Unit,Sinamics Sl150 V4.7 Control Unit,Sinamics Sm120 V4.7 Control Unit,Sinumerik 828d,Sinumerik 840d Sl,Siplus Et 200mp Im 155-5 Pn Hf,Siplus Et 200mp Im 155-5 Pn Hf T1 Rail,Siplus Et 200mp Im 155-5 Pn St,Siplus Et 200mp Im 155-5 Pn St Tx Rail,Siplus Et 200s Im 151-8 Pn/dp Cpu,Siplus Et 200s Im 151-8f Pn/dp Cpu,Siplus Et 200sp Im 155-6 Pn Hf,Siplus Et 200sp Im 155-6 Pn Hf T1 Rail,Siplus Et 200sp Im 155-6 Pn St,Siplus Et 200sp Im 155-6 Pn St Ba,Siplus Et 200sp Im 155-6 Pn St Ba Tx Rail,Siplus Et 200sp Im 155-6 Pn St Tx Rail,Siplus S7-300 Cpu 314c-2 Pn/dp,Siplus S7-300 Cpu 315-2 Pn/dp,Siplus S7-300 Cpu 315f-2 Pn/dp,Siplus S7-300 Cpu 317-2 Pn/dp,Siplus S7-300 Cpu 317f-2 Pn/dp,Siplus S7-400 Cpu 414-3 Pn/dp V7,Siplus S7-400 Cpu 416-3 Pn/dp V7",7.5,HIGH,0.0012000000569969416,false,,false,false,false,,false,false,2019-10-10T13:49:24.000Z,0 CVE-2019-6568,https://securityvulnerability.io/vulnerability/CVE-2019-6568,,"The webserver of the affected devices contains a vulnerability that may lead to a denial of service condition. An attacker may cause a denial of service situation which leads to a restart of the webserver of the affected device. The security vulnerability could be exploited by an attacker with network access to the affected systems. Successful exploitation requires no system privileges and no user interaction. An attacker could use the vulnerability to compromise availability of the device.",Siemens,"Simatic Cp 1604,Simatic Cp 1616,Simatic Cp 343-1 Advanced,Simatic Cp 443-1,Simatic Cp 443-1 Advanced,Simatic Cp 443-1 Opc Ua,Simatic Et 200pro Im154-8 Pn/dp Cpu,Simatic Et 200pro Im154-8f Pn/dp Cpu,Simatic Et 200pro Im154-8fx Pn/dp Cpu,Simatic Et 200s Im151-8 Pn/dp Cpu,Simatic Et 200s Im151-8f Pn/dp Cpu,Simatic Et 200sp Open Controller Cpu 1515sp Pc (incl. Siplus Variants),Simatic Et 200sp Open Controller Cpu 1515sp Pc2 (incl. Siplus Variants),Simatic Hmi Comfort Outdoor Panels 7"" & 15"" (incl. Siplus Variants),Simatic Hmi Comfort Panels 4"" - 22"" (incl. Siplus Variants),Simatic Hmi Ktp Mobile Panels Ktp400f, Ktp700, Ktp700f, Ktp900 And Ktp900f,Simatic Ipc Diagmonitor,Simatic Rf182c,Simatic Rf185c,Simatic Rf186c,Simatic Rf188c,Simatic Rf600r Family,Simatic Rfid 181eip,Simatic S7-1500 Cpu Family (incl. Related Et200 Cpus And Siplus Variants),Simatic S7-1500 Software Controller,Simatic S7-300 Cpu 314c-2 Pn/dp,Simatic S7-300 Cpu 315-2 Pn/dp,Simatic S7-300 Cpu 315f-2 Pn/dp,Simatic S7-300 Cpu 315t-3 Pn/dp,Simatic S7-300 Cpu 317-2 Pn/dp,Simatic S7-300 Cpu 317f-2 Pn/dp,Simatic S7-300 Cpu 317t-3 Pn/dp,Simatic S7-300 Cpu 317tf-3 Pn/dp,Simatic S7-300 Cpu 319-3 Pn/dp,Simatic S7-300 Cpu 319f-3 Pn/dp,Simatic S7-400 Pn/dp V6 And Below Cpu Family (incl. Siplus Variants),Simatic S7-400 Pn/dp V7 Cpu Family (incl. Siplus Variants),Simatic S7-plcsim Advanced,Simatic Teleservice Adapter Ie Advanced,Simatic Teleservice Adapter Ie Basic,Simatic Teleservice Adapter Ie Standard,Simatic Winac Rtx 2010,Simatic Winac Rtx F 2010,Simatic Wincc Runtime Advanced,Simocode Pro V Ethernet/ip (incl. Siplus Variants),Simocode Pro V Profinet (incl. Siplus Variants),Sinamics G130 V4.6 Control Unit,Sinamics G130 V4.7 Control Unit,Sinamics G130 V4.7 Sp1 Control Unit,Sinamics G130 V4.8 Control Unit,Sinamics G130 V5.1 Control Unit,Sinamics G130 V5.1 Sp1 Control Unit,Sinamics G150 V4.6 Control Unit,Sinamics G150 V4.7 Control Unit,Sinamics G150 V4.7 Sp1 Control Unit,Sinamics G150 V4.8 Control Unit,Sinamics G150 V5.1 Control Unit,Sinamics G150 V5.1 Sp1 Control Unit,Sinamics Gh150 V4.7 (control Unit),Sinamics Gh150 V4.8 (control Unit),Sinamics Gl150 V4.7 (control Unit),Sinamics Gl150 V4.8 (control Unit),Sinamics Gm150 V4.7 (control Unit),Sinamics Gm150 V4.8 (control Unit),Sinamics S120 V4.6 Control Unit (incl. Siplus Variants),Sinamics S120 V4.7 Control Unit (incl. Siplus Variants),Sinamics S120 V4.7 Sp1 Control Unit (incl. Siplus Variants),Sinamics S120 V4.8 Control Unit (incl. Siplus Variants),Sinamics S120 V5.1 Control Unit (incl. Siplus Variants),Sinamics S120 V5.1 Sp1 Control Unit (incl. Siplus Variants),Sinamics S150 V4.6 Control Unit,Sinamics S150 V4.7 Control Unit,Sinamics S150 V4.7 Sp1 Control Unit,Sinamics S150 V4.8 Control Unit,Sinamics S150 V5.1 Control Unit,Sinamics S150 V5.1 Sp1 Control Unit,Sinamics S210,Sinamics Sl150 V4.7 (control Unit),Sinamics Sl150 V4.8 (control Unit),Sinamics Sm120 V4.7 (control Unit),Sinamics Sm120 V4.8 (control Unit),Sinamics Sm150 V4.8 (control Unit),Siplus Et 200s Im151-8 Pn/dp Cpu,Siplus Et 200s Im151-8f Pn/dp Cpu,Siplus Net Cp 343-1 Advanced,Siplus Net Cp 443-1,Siplus Net Cp 443-1 Advanced,Siplus S7-300 Cpu 314c-2 Pn/dp,Siplus S7-300 Cpu 315-2 Pn/dp,Siplus S7-300 Cpu 315f-2 Pn/dp,Siplus S7-300 Cpu 317-2 Pn/dp,Siplus S7-300 Cpu 317f-2 Pn/dp,Sitop Manager,Sitop Psu8600,Sitop Ups1600 (incl. Siplus Variants),Tim 1531 Irc (incl. Siplus Net Variants)",7.5,HIGH,0.0012000000569969416,false,,false,false,false,,false,false,2019-04-17T13:40:24.000Z,0 CVE-2018-13810,https://securityvulnerability.io/vulnerability/CVE-2018-13810,,"A vulnerability has been identified in CP 1604 (All versions), CP 1616 (All versions). The integrated configuration web server of the affected CP devices could allow a Cross-Site Request Forgery (CSRF) attack if an unsuspecting user is tricked into accessing a malicious link. Successful exploitation requires user interaction by a legitimate user. A successful attack could allow an attacker to trigger actions via the web interface that the legitimate user is allowed to perform. At the time of advisory publication no public exploitation of this vulnerability was known.",Siemens,"Cp 1604,Cp 1616",6.5,MEDIUM,0.0005300000193528831,false,,false,false,false,,false,false,2019-04-17T13:38:34.000Z,0 CVE-2018-13808,https://securityvulnerability.io/vulnerability/CVE-2018-13808,,"A vulnerability has been identified in CP 1604 (All versions), CP 1616 (All versions). An attacker with network access to port 23/tcp could extract internal communication data or cause a Denial-of-Service condition. Successful exploitation requires network access to a vulnerable device. At the time of advisory publication no public exploitation of this vulnerability was known.",Siemens,"Cp 1604,Cp 1616",9.1,CRITICAL,0.0017000000225380063,false,,false,false,false,,false,false,2019-04-17T13:38:34.000Z,0 CVE-2018-13809,https://securityvulnerability.io/vulnerability/CVE-2018-13809,,"A vulnerability has been identified in CP 1604 (All versions), CP 1616 (All versions). The integrated web server of the affected CP devices could allow Cross-Site Scripting (XSS) attacks if unsuspecting users are tricked into following a malicious link. User interaction is required for a successful exploitation. At the time of advisory publication no public exploitation of this vulnerability was known.",Siemens,"Cp 1604,Cp 1616",6.1,MEDIUM,0.0007800000021234155,false,,false,false,false,,false,false,2019-04-17T13:38:34.000Z,0 CVE-2017-2681,https://securityvulnerability.io/vulnerability/CVE-2017-2681,,Specially crafted PROFINET DCP packets sent on a local Ethernet segment (Layer 2) to an affected product could cause a denial of service condition of that product. Human interaction is required to recover the system. PROFIBUS interfaces are not affected.,Siemens,"Development/evaluation Kits For Profinet Io: Dk Standard Ethernet Controller,Development/evaluation Kits For Profinet Io: Ek-ertec 200,Development/evaluation Kits For Profinet Io: Ek-ertec 200p,Ie/as-i Link Pn Io,Ie/pb-link (incl. Siplus Net Variants),Scalance M-800 Family (incl. S615, Mum-800 And Rm1224),Scalance W-700 Ieee 802.11n Family,Scalance X-200 Family (incl. Siplus Net Variants),Scalance X-200irt Family (incl. Siplus Net Variants),Scalance X-300 Family (incl. X408 And Siplus Net Variants),Scalance X408 Family,Scalance X414,Scalance Xm-400 Family,Scalance Xr-500 Family,Simatic Cm 1542-1,Simatic Cm 1542sp-1,Simatic Cp 1243-1 (incl. Siplus Variants),Simatic Cp 1243-1 Dnp3 (incl. Siplus Variants),Simatic Cp 1243-1 Iec (incl. Siplus Variants),Simatic Cp 1243-8 Irc,Simatic Cp 1542sp-1 Irc (incl. Siplus Variants),Simatic Cp 1543-1 (incl. Siplus Variants),Simatic Cp 1543sp-1 (incl. Siplus Variants),Simatic Cp 1604,Simatic Cp 1616,Simatic Cp 343-1 (incl. Siplus Variants),Simatic Cp 343-1 Advanced (incl. Siplus Variants),Simatic Cp 343-1 Lean (incl. Siplus Variants),Simatic Cp 443-1 (incl. Siplus Variants),Simatic Cp 443-1 Advanced (incl. Siplus Variants),Simatic Cp 443-1 Opc Ua,Simatic Dk-16xx Pn Io,Simatic Et 200al Im 157-1 Pn,Simatic Et 200m (incl. Siplus Variants),Simatic Et 200mp Im 155-5 Pn Ba,Simatic Et 200mp Im 155-5 Pn Hf,Simatic Et 200mp Im 155-5 Pn St,Simatic Et 200pro Im 154-3 Pn Hf,Simatic Et 200pro Im 154-4 Pn Hf,Simatic Et 200sp Im 155-6 Pn Ba,Simatic Et 200sp Im 155-6 Pn Hf,Simatic Et 200sp Im 155-6 Pn Hs,Simatic Et 200sp Im 155-6 Pn St,Simatic Et 200sp Im 155-6 Pn St Ba,Simatic Et200ecopn, 16di, Dc24v, 8xm12,Simatic Et200ecopn, 16do Dc24v/1,3a, 8xm12,Simatic Et200ecopn, 4ao U/i 4xm12,Simatic Et200ecopn, 8 Dio, Dc24v/1,3a, 8xm12,Simatic Et200ecopn, 8 Do, Dc24v/2a, 8xm12,Simatic Et200ecopn, 8ai Rtd/tc 8xm12,Simatic Et200ecopn, 8ai; 4 U/i; 4 Rtd/tc 8xm12,Simatic Et200ecopn, 8di, Dc24v, 4xm12,Simatic Et200ecopn, 8di, Dc24v, 8xm12,Simatic Et200ecopn, 8do, Dc24v/0,5a, 4xm12,Simatic Et200ecopn, 8do, Dc24v/1,3a, 4xm12,Simatic Et200ecopn, 8do, Dc24v/1,3a, 8xm12,Simatic Et200ecopn: Io-link Master,Simatic Et200s (incl. Siplus Variants),Simatic Hmi Comfort Panels, Hmi Multi Panels, Hmi Mobile Panels (incl. Siplus Variants),Simatic Mv420 Sr-b,Simatic Mv420 Sr-b Body,Simatic Mv420 Sr-p,Simatic Mv420 Sr-p Body,Simatic Mv440 Hr,Simatic Mv440 Sr,Simatic Mv440 Ur,Simatic Pn/pn Coupler (incl. Siplus Net Variants),Simatic Rf650r,Simatic Rf680r,Simatic Rf685r,Simatic S7-1200 Cpu Family (incl. Siplus Variants),Simatic S7-1500 Cpu Family (incl. Related Et200 Cpus And Siplus Variants),Simatic S7-1500 Software Controller,Simatic S7-200 Smart,Simatic S7-300 Cpu Family (incl. Related Et200 Cpus And Siplus Variants),Simatic S7-400 H V6 Cpu Family (incl. Siplus Variants),Simatic S7-400 Pn/dp V6 Cpu Family (incl. Siplus Variants),Simatic S7-400 Pn/dp V7 Cpu Family (incl. Siplus Variants),Simatic S7-410 Cpu Family (incl. Siplus Variants),Simatic Tdc Cp51m1,Simatic Tdc Cpu555,Simatic Teleservice Adapter Ie Advanced,Simatic Teleservice Adapter Ie Basic,Simatic Teleservice Adapter Ie Standard,Simatic Winac Rtx 2010,Simatic Winac Rtx F 2010,Simocode Pro V Profinet (incl. Siplus Variants),Simotion,Sinamics Dcm W. Pn,Sinamics Dcp W. Pn,Sinamics G110m W. Pn,Sinamics G120(c/p/d) W. Pn (incl. Siplus Variants),Sinamics G130 V4.7 W. Pn,Sinamics G130 V4.8 W. Pn,Sinamics G150 V4.7 W. Pn,Sinamics G150 V4.8 W. Pn,Sinamics S110 W. Pn,Sinamics S120 Prior To V4.7 W. Pn (incl. Siplus Variants),Sinamics S120 V4.7 Sp1 W. Pn (incl. Siplus Variants),Sinamics S120 V4.7 W. Pn (incl. Siplus Variants),Sinamics S120 V4.8 W. Pn (incl. Siplus Variants),Sinamics S150 V4.7 W. Pn,Sinamics S150 V4.8 W. Pn,Sinamics V90 W. Pn,Sinumerik 828d V4.5 And Prior,Sinumerik 828d V4.7,Sinumerik 840d Sl V4.5 And Prior,Sinumerik 840d Sl V4.7,Siplus Et 200mp Im 155-5 Pn Hf,Siplus Et 200mp Im 155-5 Pn Hf T1 Rail,Siplus Et 200mp Im 155-5 Pn St,Siplus Et 200mp Im 155-5 Pn St Tx Rail,Siplus Et 200sp Im 155-6 Pn Hf,Siplus Et 200sp Im 155-6 Pn Hf T1 Rail,Siplus Et 200sp Im 155-6 Pn St,Siplus Et 200sp Im 155-6 Pn St Ba,Siplus Et 200sp Im 155-6 Pn St Ba Tx Rail,Siplus Et 200sp Im 155-6 Pn St Tx Rail,Sirius Act 3su1 Interface Module Profinet,Sirius Motor Starter M200d Profinet,Sirius Soft Starter 3rw44 Pn,Sitop Psu8600 Profinet,Sitop Ups1600 Profinet (incl. Siplus Variants),Softnet Profinet Io For Pc-based Windows Systems",6.5,MEDIUM,0.0019399999873712659,false,,false,false,false,,false,false,2017-05-11T10:00:00.000Z,0 CVE-2017-2680,https://securityvulnerability.io/vulnerability/CVE-2017-2680,,Specially crafted PROFINET DCP broadcast packets could cause a denial of service condition of affected products on a local Ethernet segment (Layer 2). Human interaction is required to recover the systems. PROFIBUS interfaces are not affected.,Siemens,"Development/evaluation Kits For Profinet Io: Dk Standard Ethernet Controller,Development/evaluation Kits For Profinet Io: Ek-ertec 200,Development/evaluation Kits For Profinet Io: Ek-ertec 200p,Extension Unit 12"" Profinet,Extension Unit 15"" Profinet,Extension Unit 19"" Profinet,Extension Unit 22"" Profinet,Ie/as-i Link Pn Io,Ie/pb-link (incl. Siplus Net Variants),Scalance M-800 Family (incl. S615, Mum-800 And Rm1224),Scalance W-700 Ieee 802.11n Family,Scalance X-200 Family (incl. Siplus Net Variants),Scalance X-200irt Family (incl. Siplus Net Variants),Scalance X-300 Family (incl. X408 And Siplus Net Variants),Scalance X408 Family,Scalance X414,Scalance Xm-400 Family,Scalance Xr-500 Family,Simatic Cm 1542-1,Simatic Cm 1542sp-1,Simatic Cp 1242-7 V2 (incl. Siplus Variants),Simatic Cp 1243-1 (incl. Siplus Variants),Simatic Cp 1243-1 Dnp3 (incl. Siplus Variants),Simatic Cp 1243-1 Iec (incl. Siplus Variants),Simatic Cp 1243-7 Lte Us,Simatic Cp 1243-8 Irc,Simatic Cp 1542sp-1 Irc (incl. Siplus Variants),Simatic Cp 1543-1 (incl. Siplus Variants),Simatic Cp 1543sp-1 (incl. Siplus Variants),Simatic Cp 1604,Simatic Cp 1616,Simatic Cp 1626,Simatic Cp 343-1 (incl. Siplus Variants),Simatic Cp 343-1 Advanced (incl. Siplus Variants),Simatic Cp 343-1 Lean (incl. Siplus Variants),Simatic Cp 443-1 (incl. Siplus Variants),Simatic Cp 443-1 Advanced (incl. Siplus Variants),Simatic Cp 443-1 Opc Ua,Simatic Dk-16xx Pn Io,Simatic Et 200al Im 157-1 Pn,Simatic Et 200m (incl. Siplus Variants),Simatic Et 200mp Im 155-5 Pn Ba,Simatic Et 200mp Im 155-5 Pn Hf,Simatic Et 200mp Im 155-5 Pn St,Simatic Et 200pro Im 154-3 Pn Hf,Simatic Et 200pro Im 154-4 Pn Hf,Simatic Et 200sp Im 155-6 Pn Ba,Simatic Et 200sp Im 155-6 Pn Hf,Simatic Et 200sp Im 155-6 Pn Hs,Simatic Et 200sp Im 155-6 Pn St,Simatic Et 200sp Im 155-6 Pn St Ba,Simatic Et200ecopn, 16di, Dc24v, 8xm12,Simatic Et200ecopn, 16do Dc24v/1,3a, 8xm12,Simatic Et200ecopn, 4ao U/i 4xm12,Simatic Et200ecopn, 8 Dio, Dc24v/1,3a, 8xm12,Simatic Et200ecopn, 8 Do, Dc24v/2a, 8xm12,Simatic Et200ecopn, 8ai Rtd/tc 8xm12,Simatic Et200ecopn, 8ai; 4 U/i; 4 Rtd/tc 8xm12,Simatic Et200ecopn, 8di, Dc24v, 4xm12,Simatic Et200ecopn, 8di, Dc24v, 8xm12,Simatic Et200ecopn, 8do, Dc24v/0,5a, 4xm12,Simatic Et200ecopn, 8do, Dc24v/1,3a, 4xm12,Simatic Et200ecopn, 8do, Dc24v/1,3a, 8xm12,Simatic Et200ecopn: Io-link Master,Simatic Et200s (incl. Siplus Variants),Simatic Hmi Comfort Panels, Hmi Multi Panels, Hmi Mobile Panels (incl. Siplus Variants),Simatic Mv420 Sr-b,Simatic Mv420 Sr-b Body,Simatic Mv420 Sr-p,Simatic Mv420 Sr-p Body,Simatic Mv440 Hr,Simatic Mv440 Sr,Simatic Mv440 Ur,Simatic Pn/pn Coupler (incl. Siplus Net Variants),Simatic Rf650r,Simatic Rf680r,Simatic Rf685r,Simatic S7-1200 Cpu Family (incl. Siplus Variants),Simatic S7-1500 Cpu Family (incl. Related Et200 Cpus And Siplus Variants),Simatic S7-1500 Software Controller,Simatic S7-200 Smart,Simatic S7-300 Cpu Family (incl. Related Et200 Cpus And Siplus Variants),Simatic S7-400 H V6 Cpu Family (incl. Siplus Variants),Simatic S7-400 Pn/dp V6 Cpu Family (incl. Siplus Variants),Simatic S7-400 Pn/dp V7 Cpu Family (incl. Siplus Variants),Simatic S7-410 Cpu Family (incl. Siplus Variants),Simatic Tdc Cp51m1,Simatic Tdc Cpu555,Simatic Teleservice Adapter Ie Advanced,Simatic Teleservice Adapter Ie Basic,Simatic Teleservice Adapter Ie Standard,Simatic Winac Rtx 2010,Simatic Winac Rtx F 2010,Simocode Pro V Profinet (incl. Siplus Variants),Simotion,Simotion D4xx V4.4 For Sinamics Sm150i-2 W. Profinet (incl. Siplus Variants),Sinamics Dcm W. Pn,Sinamics Dcp W. Pn,Sinamics G110m W. Pn,Sinamics G120(c/p/d) W. Pn (incl. Siplus Variants),Sinamics G130 V4.7 W. Pn,Sinamics G130 V4.8 W. Pn,Sinamics G150 V4.7 W. Pn,Sinamics G150 V4.8 W. Pn,Sinamics Gh150 V4.7 W. Profinet,Sinamics Gl150 V4.7 W. Profinet,Sinamics Gm150 V4.7 W. Profinet,Sinamics S110 W. Pn,Sinamics S120 Prior To V4.7 W. Pn (incl. Siplus Variants),Sinamics S120 V4.7 Sp1 W. Pn (incl. Siplus Variants),Sinamics S120 V4.7 W. Pn (incl. Siplus Variants),Sinamics S120 V4.8 W. Pn (incl. Siplus Variants),Sinamics S150 V4.7 W. Pn,Sinamics S150 V4.8 W. Pn,Sinamics Sl150 V4.7.0 W. Profinet,Sinamics Sl150 V4.7.4 W. Profinet,Sinamics Sl150 V4.7.5 W. Profinet,Sinamics Sm120 V4.7 W. Profinet,Sinamics V90 W. Pn,Sinumerik 828d V4.5 And Prior,Sinumerik 828d V4.7,Sinumerik 840d Sl V4.5 And Prior,Sinumerik 840d Sl V4.7,Siplus Et 200mp Im 155-5 Pn Hf,Siplus Et 200mp Im 155-5 Pn Hf T1 Rail,Siplus Et 200mp Im 155-5 Pn St,Siplus Et 200mp Im 155-5 Pn St Tx Rail,Siplus Et 200sp Im 155-6 Pn Hf,Siplus Et 200sp Im 155-6 Pn Hf T1 Rail,Siplus Et 200sp Im 155-6 Pn St,Siplus Et 200sp Im 155-6 Pn St Ba,Siplus Et 200sp Im 155-6 Pn St Ba Tx Rail,Siplus Et 200sp Im 155-6 Pn St Tx Rail,Sirius Act 3su1 Interface Module Profinet,Sirius Motor Starter M200d Profinet,Sirius Soft Starter 3rw44 Pn,Sitop Psu8600 Profinet,Sitop Ups1600 Profinet (incl. Siplus Variants),Softnet Profinet Io For Pc-based Windows Systems",6.5,MEDIUM,0.0024999999441206455,false,,false,false,false,,false,false,2017-05-11T01:00:00.000Z,0 CVE-2013-0659,https://securityvulnerability.io/vulnerability/CVE-2013-0659,,The debugging feature on the Siemens CP 1604 and CP 1616 interface cards with firmware before 2.5.2 allows remote attackers to execute arbitrary code via a crafted packet to UDP port 17185.,Siemens,"Cp 1604 Firmware,Cp 1616 Firmware,Cp 1616,Cp 1604",,,0.15851999819278717,false,,false,false,false,,false,false,2013-04-01T16:55:00.000Z,0