cve,link,title,description,vendor,products,score,severity,epss,cisa,cisa_published,article,ransomware,exploited,poc,trended,trended_no_1,published,trended_score CVE-2023-48364,https://securityvulnerability.io/vulnerability/CVE-2023-48364,Remote Procedure Call Vulnerability in OpenPCS and SIMATIC Products by Siemens,"A vulnerability exists in certain Siemens OpenPCS and SIMATIC products due to improper handling of malformed Remote Procedure Call (RPC) messages. This oversight could allow an attacker to exploit the vulnerability, leading to a denial of service condition in the RPC server, thereby impacting the availability and functionality of the affected systems. It is crucial for users to apply the updates provided by Siemens to mitigate potential risks associated with this vulnerability.",Siemens,"Openpcs 7 V9.1,Simatic Batch V9.1,Simatic Pcs 7 V9.1,Simatic Route Control V9.1,Simatic Wincc Runtime Professional V18,Simatic Wincc Runtime Professional V19,Simatic Wincc V7.4,Simatic Wincc V7.5,Simatic Wincc V8.0",6.5,MEDIUM,0.0004400000034365803,false,,false,false,false,,false,false,2024-02-13T08:59:56.648Z,0 CVE-2023-48363,https://securityvulnerability.io/vulnerability/CVE-2023-48363,Remote Procedure Call Vulnerability in Siemens OpenPCS and SIMATIC Products,"A vulnerability exists in certain versions of Siemens OpenPCS and SIMATIC products due to improper handling of specific unorganized Remote Procedure Call (RPC) messages. This flaw can be exploited by an attacker to trigger a denial of service condition in the RPC server, potentially disrupting operations across affected systems. Timely updates to the latest service packs are recommended to mitigate this risk.",Siemens,"Openpcs 7 V9.1,Simatic Batch V9.1,Simatic Pcs 7 V9.1,Simatic Route Control V9.1,Simatic Wincc Runtime Professional V18,Simatic Wincc Runtime Professional V19,Simatic Wincc V7.4,Simatic Wincc V7.5,Simatic Wincc V8.0",6.5,MEDIUM,0.0004400000034365803,false,,false,false,false,,false,false,2024-02-13T08:59:55.432Z,0 CVE-2018-4832,https://securityvulnerability.io/vulnerability/CVE-2018-4832,,"A vulnerability has been identified in OpenPCS 7 V7.1 and earlier (All versions), OpenPCS 7 V8.0 (All versions), OpenPCS 7 V8.1 (All versions < V8.1 Upd5), OpenPCS 7 V8.2 (All versions), OpenPCS 7 V9.0 (All versions < V9.0 Upd1), SIMATIC BATCH V7.1 and earlier (All versions), SIMATIC BATCH V8.0 (All versions < V8.0 SP1 Upd21), SIMATIC BATCH V8.1 (All versions < V8.1 SP1 Upd16), SIMATIC BATCH V8.2 (All versions < V8.2 Upd10), SIMATIC BATCH V9.0 (All versions < V9.0 SP1), SIMATIC NET PC Software V14 (All versions < V14 SP1 Update 14), SIMATIC NET PC Software V15 (All versions < 15 SP1), SIMATIC PCS 7 V7.1 and earlier (All versions), SIMATIC PCS 7 V8.0 (All versions), SIMATIC PCS 7 V8.1 (All versions), SIMATIC PCS 7 V8.2 (All versions < V8.2 SP1), SIMATIC PCS 7 V9.0 (All versions < V9.0 SP1), SIMATIC Route Control V7.1 and earlier (All versions), SIMATIC Route Control V8.0 (All versions), SIMATIC Route Control V8.1 (All versions), SIMATIC Route Control V8.2 (All versions), SIMATIC Route Control V9.0 (All versions < V9.0 Upd1), SIMATIC WinCC Runtime Professional V13 (All versions < V13 SP2 Upd2), SIMATIC WinCC Runtime Professional V14 (All versions < V14 SP1 Upd5), SIMATIC WinCC V7.2 and earlier (All versions < WinCC 7.2 Upd 15), SIMATIC WinCC V7.3 (All versions < WinCC 7.3 Upd 16), SIMATIC WinCC V7.4 (All versions < V7.4 SP1 Upd 4), SPPA-T3000 Application Server (All versions < Service Pack R8.2 SP2). Specially crafted messages sent to the RPC service of the affected products could cause a Denial-of-Service condition on the remote and local communication functionality of the affected products. A reboot of the system is required to recover the remote and local communication functionality. Please note that an attacker needs to have network access to the Application Server in order to exploit this vulnerability. At the time of advisory publication no public exploitation of this security vulnerability was known.",Siemens,"Openpcs 7 V7.1 And Earlier,Openpcs 7 V8.0,Openpcs 7 V8.1,Openpcs 7 V8.2,Openpcs 7 V9.0,Simatic Batch V7.1 And Earlier,Simatic Batch V8.0,Simatic Batch V8.1,Simatic Batch V8.2,Simatic Batch V9.0,Simatic Net Pc Software V14,Simatic Net Pc Software V15,Simatic Pcs 7 V7.1 And Earlier,Simatic Pcs 7 V8.0,Simatic Pcs 7 V8.1,Simatic Pcs 7 V8.2,Simatic Pcs 7 V9.0,Simatic Route Control V7.1 And Earlier,Simatic Route Control V8.0,Simatic Route Control V8.1,Simatic Route Control V8.2,Simatic Route Control V9.0,Simatic Wincc Runtime Professional V13,Simatic Wincc Runtime Professional V14,Simatic Wincc V7.2 And Earlier,Simatic Wincc V7.3,Simatic Wincc V7.4,Sppa-t3000 Application Server",7.5,HIGH,0.004120000172406435,false,,false,false,false,,false,false,2018-04-24T17:00:00.000Z,0