cve,link,title,description,vendor,products,score,severity,epss,cisa,cisa_published,article,ransomware,exploited,poc,trended,trended_no_1,published,trended_score CVE-2021-44695,https://securityvulnerability.io/vulnerability/CVE-2021-44695,Denial of Service Vulnerability in Siemens Products,"Certain Siemens devices are vulnerable to a denial of service attack when processing specifically crafted packets sent to port 102/tcp. This flaw can prevent affected devices from functioning correctly, potentially leading to disruption of services. Organizations using these devices should implement mitigations to reduce exposure to such attacks.",Siemens,"Simatic Drive Controller Cpu 1504d Tf,Simatic Drive Controller Cpu 1507d Tf,Simatic Et 200sp Open Controller Cpu 1515sp Pc2 (incl. Siplus Variants),Simatic S7-1200 Cpu Family (incl. Siplus Variants),Simatic S7-1500 Cpu 1510sp F-1 Pn,Simatic S7-1500 Cpu 1510sp-1 Pn,Simatic S7-1500 Cpu 1511-1 Pn,Simatic S7-1500 Cpu 1511c-1 Pn,Simatic S7-1500 Cpu 1511f-1 Pn,Simatic S7-1500 Cpu 1511t-1 Pn,Simatic S7-1500 Cpu 1511tf-1 Pn,Simatic S7-1500 Cpu 1512c-1 Pn,Simatic S7-1500 Cpu 1512sp F-1 Pn,Simatic S7-1500 Cpu 1512sp-1 Pn,Simatic S7-1500 Cpu 1513-1 Pn,Simatic S7-1500 Cpu 1513f-1 Pn,Simatic S7-1500 Cpu 1513r-1 Pn,Simatic S7-1500 Cpu 1515-2 Pn,Simatic S7-1500 Cpu 1515f-2 Pn,Simatic S7-1500 Cpu 1515r-2 Pn,Simatic S7-1500 Cpu 1515t-2 Pn,Simatic S7-1500 Cpu 1515tf-2 Pn,Simatic S7-1500 Cpu 1516-3 Pn/dp,Simatic S7-1500 Cpu 1516f-3 Pn/dp,Simatic S7-1500 Cpu 1516t-3 Pn/dp,Simatic S7-1500 Cpu 1516tf-3 Pn/dp,Simatic S7-1500 Cpu 1517-3 Pn/dp,Simatic S7-1500 Cpu 1517f-3 Pn/dp,Simatic S7-1500 Cpu 1517h-3 Pn,Simatic S7-1500 Cpu 1517t-3 Pn/dp,Simatic S7-1500 Cpu 1517tf-3 Pn/dp,Simatic S7-1500 Cpu 1518-4 Pn/dp,Simatic S7-1500 Cpu 1518-4 Pn/dp Mfp,Simatic S7-1500 Cpu 1518f-4 Pn/dp,Simatic S7-1500 Cpu 1518f-4 Pn/dp Mfp,Simatic S7-1500 Cpu 1518hf-4 Pn,Simatic S7-1500 Cpu 1518t-4 Pn/dp,Simatic S7-1500 Cpu 1518tf-4 Pn/dp,Simatic S7-1500 Cpu S7-1518-4 Pn/dp Odk,Simatic S7-1500 Cpu S7-1518f-4 Pn/dp Odk,Simatic S7-1500 Et 200pro: Cpu 1513pro F-2 Pn,Simatic S7-1500 Et 200pro: Cpu 1513pro-2 Pn,Simatic S7-1500 Et 200pro: Cpu 1516pro F-2 Pn,Simatic S7-1500 Et 200pro: Cpu 1516pro-2 Pn,Simatic S7-1500 Software Controller V2,Simatic S7-plcsim Advanced,Siplus Et 200sp Cpu 1510sp F-1 Pn,Siplus Et 200sp Cpu 1510sp F-1 Pn Rail,Siplus Et 200sp Cpu 1510sp-1 Pn,Siplus Et 200sp Cpu 1510sp-1 Pn Rail,Siplus Et 200sp Cpu 1512sp F-1 Pn,Siplus Et 200sp Cpu 1512sp F-1 Pn Rail,Siplus Et 200sp Cpu 1512sp-1 Pn,Siplus Et 200sp Cpu 1512sp-1 Pn Rail,Siplus S7-1500 Cpu 1511-1 Pn,Siplus S7-1500 Cpu 1511-1 Pn T1 Rail,Siplus S7-1500 Cpu 1511-1 Pn Tx Rail,Siplus S7-1500 Cpu 1511f-1 Pn,Siplus S7-1500 Cpu 1513-1 Pn,Siplus S7-1500 Cpu 1513f-1 Pn,Siplus S7-1500 Cpu 1515f-2 Pn,Siplus S7-1500 Cpu 1515f-2 Pn Rail,Siplus S7-1500 Cpu 1515f-2 Pn T2 Rail,Siplus S7-1500 Cpu 1515r-2 Pn,Siplus S7-1500 Cpu 1515r-2 Pn Tx Rail,Siplus S7-1500 Cpu 1516-3 Pn/dp,Siplus S7-1500 Cpu 1516-3 Pn/dp Rail,Siplus S7-1500 Cpu 1516-3 Pn/dp Tx Rail,Siplus S7-1500 Cpu 1516f-3 Pn/dp,Siplus S7-1500 Cpu 1516f-3 Pn/dp Rail,Siplus S7-1500 Cpu 1517h-3 Pn,Siplus S7-1500 Cpu 1518-4 Pn/dp,Siplus S7-1500 Cpu 1518-4 Pn/dp Mfp,Siplus S7-1500 Cpu 1518f-4 Pn/dp,Siplus S7-1500 Cpu 1518hf-4 Pn,Siplus Tim 1531 Irc,Tim 1531 Irc",4.9,MEDIUM,0.0004400000034365803,false,,false,false,false,,false,false,2022-12-13T00:00:00.000Z,0 CVE-2021-44694,https://securityvulnerability.io/vulnerability/CVE-2021-44694,Denial of Service Risk in Siemens Devices,"Certain Siemens industrial devices are susceptible to a vulnerability related to the improper handling of specially crafted packets transmitted to TCP port 102. Exploiting this flaw may enable an attacker to create a denial of service condition, disrupting operations and potentially leading to significant downtime.",Siemens,"Simatic Drive Controller Cpu 1504d Tf,Simatic Drive Controller Cpu 1507d Tf,Simatic Et 200sp Open Controller Cpu 1515sp Pc2 (incl. Siplus Variants),Simatic S7-1200 Cpu Family (incl. Siplus Variants),Simatic S7-1500 Cpu 1510sp F-1 Pn,Simatic S7-1500 Cpu 1510sp-1 Pn,Simatic S7-1500 Cpu 1511-1 Pn,Simatic S7-1500 Cpu 1511c-1 Pn,Simatic S7-1500 Cpu 1511f-1 Pn,Simatic S7-1500 Cpu 1511t-1 Pn,Simatic S7-1500 Cpu 1511tf-1 Pn,Simatic S7-1500 Cpu 1512c-1 Pn,Simatic S7-1500 Cpu 1512sp F-1 Pn,Simatic S7-1500 Cpu 1512sp-1 Pn,Simatic S7-1500 Cpu 1513-1 Pn,Simatic S7-1500 Cpu 1513f-1 Pn,Simatic S7-1500 Cpu 1513r-1 Pn,Simatic S7-1500 Cpu 1515-2 Pn,Simatic S7-1500 Cpu 1515f-2 Pn,Simatic S7-1500 Cpu 1515r-2 Pn,Simatic S7-1500 Cpu 1515t-2 Pn,Simatic S7-1500 Cpu 1515tf-2 Pn,Simatic S7-1500 Cpu 1516-3 Pn/dp,Simatic S7-1500 Cpu 1516f-3 Pn/dp,Simatic S7-1500 Cpu 1516t-3 Pn/dp,Simatic S7-1500 Cpu 1516tf-3 Pn/dp,Simatic S7-1500 Cpu 1517-3 Pn/dp,Simatic S7-1500 Cpu 1517f-3 Pn/dp,Simatic S7-1500 Cpu 1517h-3 Pn,Simatic S7-1500 Cpu 1517t-3 Pn/dp,Simatic S7-1500 Cpu 1517tf-3 Pn/dp,Simatic S7-1500 Cpu 1518-4 Pn/dp,Simatic S7-1500 Cpu 1518-4 Pn/dp Mfp,Simatic S7-1500 Cpu 1518f-4 Pn/dp,Simatic S7-1500 Cpu 1518f-4 Pn/dp Mfp,Simatic S7-1500 Cpu 1518hf-4 Pn,Simatic S7-1500 Cpu 1518t-4 Pn/dp,Simatic S7-1500 Cpu 1518tf-4 Pn/dp,Simatic S7-1500 Cpu S7-1518-4 Pn/dp Odk,Simatic S7-1500 Cpu S7-1518f-4 Pn/dp Odk,Simatic S7-1500 Et 200pro: Cpu 1513pro F-2 Pn,Simatic S7-1500 Et 200pro: Cpu 1513pro-2 Pn,Simatic S7-1500 Et 200pro: Cpu 1516pro F-2 Pn,Simatic S7-1500 Et 200pro: Cpu 1516pro-2 Pn,Simatic S7-1500 Software Controller V2,Simatic S7-plcsim Advanced,Siplus Et 200sp Cpu 1510sp F-1 Pn,Siplus Et 200sp Cpu 1510sp F-1 Pn Rail,Siplus Et 200sp Cpu 1510sp-1 Pn,Siplus Et 200sp Cpu 1510sp-1 Pn Rail,Siplus Et 200sp Cpu 1512sp F-1 Pn,Siplus Et 200sp Cpu 1512sp F-1 Pn Rail,Siplus Et 200sp Cpu 1512sp-1 Pn,Siplus Et 200sp Cpu 1512sp-1 Pn Rail,Siplus S7-1500 Cpu 1511-1 Pn,Siplus S7-1500 Cpu 1511-1 Pn T1 Rail,Siplus S7-1500 Cpu 1511-1 Pn Tx Rail,Siplus S7-1500 Cpu 1511f-1 Pn,Siplus S7-1500 Cpu 1513-1 Pn,Siplus S7-1500 Cpu 1513f-1 Pn,Siplus S7-1500 Cpu 1515f-2 Pn,Siplus S7-1500 Cpu 1515f-2 Pn Rail,Siplus S7-1500 Cpu 1515f-2 Pn T2 Rail,Siplus S7-1500 Cpu 1515r-2 Pn,Siplus S7-1500 Cpu 1515r-2 Pn Tx Rail,Siplus S7-1500 Cpu 1516-3 Pn/dp,Siplus S7-1500 Cpu 1516-3 Pn/dp Rail,Siplus S7-1500 Cpu 1516-3 Pn/dp Tx Rail,Siplus S7-1500 Cpu 1516f-3 Pn/dp,Siplus S7-1500 Cpu 1516f-3 Pn/dp Rail,Siplus S7-1500 Cpu 1517h-3 Pn,Siplus S7-1500 Cpu 1518-4 Pn/dp,Siplus S7-1500 Cpu 1518-4 Pn/dp Mfp,Siplus S7-1500 Cpu 1518f-4 Pn/dp,Siplus S7-1500 Cpu 1518hf-4 Pn,Siplus Tim 1531 Irc,Tim 1531 Irc",5.5,MEDIUM,0.0004400000034365803,false,,false,false,false,,false,false,2022-12-13T00:00:00.000Z,0 CVE-2021-40365,https://securityvulnerability.io/vulnerability/CVE-2021-40365,Denial of Service Vulnerability in Siemens Devices,"This vulnerability involves the improper processing of specially crafted packets sent to port 102/tcp in Siemens devices, which can lead to a denial of service condition. Attackers may exploit this flaw to disrupt device functionality, causing service interruptions in critical operations.",Siemens,"Simatic Drive Controller Cpu 1504d Tf,Simatic Drive Controller Cpu 1507d Tf,Simatic Et 200sp Open Controller Cpu 1515sp Pc2 (incl. Siplus Variants),Simatic S7-1200 Cpu Family (incl. Siplus Variants),Simatic S7-1500 Cpu 1510sp F-1 Pn,Simatic S7-1500 Cpu 1510sp-1 Pn,Simatic S7-1500 Cpu 1511-1 Pn,Simatic S7-1500 Cpu 1511c-1 Pn,Simatic S7-1500 Cpu 1511f-1 Pn,Simatic S7-1500 Cpu 1511t-1 Pn,Simatic S7-1500 Cpu 1511tf-1 Pn,Simatic S7-1500 Cpu 1512c-1 Pn,Simatic S7-1500 Cpu 1512sp F-1 Pn,Simatic S7-1500 Cpu 1512sp-1 Pn,Simatic S7-1500 Cpu 1513-1 Pn,Simatic S7-1500 Cpu 1513f-1 Pn,Simatic S7-1500 Cpu 1513r-1 Pn,Simatic S7-1500 Cpu 1515-2 Pn,Simatic S7-1500 Cpu 1515f-2 Pn,Simatic S7-1500 Cpu 1515r-2 Pn,Simatic S7-1500 Cpu 1515t-2 Pn,Simatic S7-1500 Cpu 1515tf-2 Pn,Simatic S7-1500 Cpu 1516-3 Pn/dp,Simatic S7-1500 Cpu 1516f-3 Pn/dp,Simatic S7-1500 Cpu 1516t-3 Pn/dp,Simatic S7-1500 Cpu 1516tf-3 Pn/dp,Simatic S7-1500 Cpu 1517-3 Pn/dp,Simatic S7-1500 Cpu 1517f-3 Pn/dp,Simatic S7-1500 Cpu 1517h-3 Pn,Simatic S7-1500 Cpu 1517t-3 Pn/dp,Simatic S7-1500 Cpu 1517tf-3 Pn/dp,Simatic S7-1500 Cpu 1518-4 Pn/dp,Simatic S7-1500 Cpu 1518-4 Pn/dp Mfp,Simatic S7-1500 Cpu 1518f-4 Pn/dp,Simatic S7-1500 Cpu 1518f-4 Pn/dp Mfp,Simatic S7-1500 Cpu 1518hf-4 Pn,Simatic S7-1500 Cpu 1518t-4 Pn/dp,Simatic S7-1500 Cpu 1518tf-4 Pn/dp,Simatic S7-1500 Cpu S7-1518-4 Pn/dp Odk,Simatic S7-1500 Cpu S7-1518f-4 Pn/dp Odk,Simatic S7-1500 Et 200pro: Cpu 1513pro F-2 Pn,Simatic S7-1500 Et 200pro: Cpu 1513pro-2 Pn,Simatic S7-1500 Et 200pro: Cpu 1516pro F-2 Pn,Simatic S7-1500 Et 200pro: Cpu 1516pro-2 Pn,Simatic S7-1500 Software Controller V2,Simatic S7-plcsim Advanced,Siplus Et 200sp Cpu 1510sp F-1 Pn,Siplus Et 200sp Cpu 1510sp F-1 Pn Rail,Siplus Et 200sp Cpu 1510sp-1 Pn,Siplus Et 200sp Cpu 1510sp-1 Pn Rail,Siplus Et 200sp Cpu 1512sp F-1 Pn,Siplus Et 200sp Cpu 1512sp F-1 Pn Rail,Siplus Et 200sp Cpu 1512sp-1 Pn,Siplus Et 200sp Cpu 1512sp-1 Pn Rail,Siplus S7-1500 Cpu 1511-1 Pn,Siplus S7-1500 Cpu 1511-1 Pn T1 Rail,Siplus S7-1500 Cpu 1511-1 Pn Tx Rail,Siplus S7-1500 Cpu 1511f-1 Pn,Siplus S7-1500 Cpu 1513-1 Pn,Siplus S7-1500 Cpu 1513f-1 Pn,Siplus S7-1500 Cpu 1515f-2 Pn,Siplus S7-1500 Cpu 1515f-2 Pn Rail,Siplus S7-1500 Cpu 1515f-2 Pn T2 Rail,Siplus S7-1500 Cpu 1515r-2 Pn,Siplus S7-1500 Cpu 1515r-2 Pn Tx Rail,Siplus S7-1500 Cpu 1516-3 Pn/dp,Siplus S7-1500 Cpu 1516-3 Pn/dp Rail,Siplus S7-1500 Cpu 1516-3 Pn/dp Tx Rail,Siplus S7-1500 Cpu 1516f-3 Pn/dp,Siplus S7-1500 Cpu 1516f-3 Pn/dp Rail,Siplus S7-1500 Cpu 1517h-3 Pn,Siplus S7-1500 Cpu 1518-4 Pn/dp,Siplus S7-1500 Cpu 1518-4 Pn/dp Mfp,Siplus S7-1500 Cpu 1518f-4 Pn/dp,Siplus S7-1500 Cpu 1518hf-4 Pn,Siplus Tim 1531 Irc,Tim 1531 Irc",7.5,HIGH,0.0004400000034365803,false,,false,false,false,,false,false,2022-12-13T00:00:00.000Z,0 CVE-2021-44693,https://securityvulnerability.io/vulnerability/CVE-2021-44693,Denial of Service Vulnerability in Siemens Devices Due to Improper Packet Handling,"Certain Siemens devices fail to correctly handle specially crafted packets directed at port 102/tcp. This flaw can be exploited by an attacker to disrupt normal operations, leading to a denial of service condition. Organizations using affected Siemens products should review their network configurations and apply recommended mitigations to safeguard against potential exploitation.",Siemens,"Simatic Drive Controller Cpu 1504d Tf,Simatic Drive Controller Cpu 1507d Tf,Simatic Et 200sp Open Controller Cpu 1515sp Pc2 (incl. Siplus Variants),Simatic S7-1200 Cpu Family (incl. Siplus Variants),Simatic S7-1500 Cpu 1510sp F-1 Pn,Simatic S7-1500 Cpu 1510sp-1 Pn,Simatic S7-1500 Cpu 1511-1 Pn,Simatic S7-1500 Cpu 1511c-1 Pn,Simatic S7-1500 Cpu 1511f-1 Pn,Simatic S7-1500 Cpu 1511t-1 Pn,Simatic S7-1500 Cpu 1511tf-1 Pn,Simatic S7-1500 Cpu 1512c-1 Pn,Simatic S7-1500 Cpu 1512sp F-1 Pn,Simatic S7-1500 Cpu 1512sp-1 Pn,Simatic S7-1500 Cpu 1513-1 Pn,Simatic S7-1500 Cpu 1513f-1 Pn,Simatic S7-1500 Cpu 1513r-1 Pn,Simatic S7-1500 Cpu 1515-2 Pn,Simatic S7-1500 Cpu 1515f-2 Pn,Simatic S7-1500 Cpu 1515r-2 Pn,Simatic S7-1500 Cpu 1515t-2 Pn,Simatic S7-1500 Cpu 1515tf-2 Pn,Simatic S7-1500 Cpu 1516-3 Pn/dp,Simatic S7-1500 Cpu 1516f-3 Pn/dp,Simatic S7-1500 Cpu 1516t-3 Pn/dp,Simatic S7-1500 Cpu 1516tf-3 Pn/dp,Simatic S7-1500 Cpu 1517-3 Pn/dp,Simatic S7-1500 Cpu 1517f-3 Pn/dp,Simatic S7-1500 Cpu 1517h-3 Pn,Simatic S7-1500 Cpu 1517t-3 Pn/dp,Simatic S7-1500 Cpu 1517tf-3 Pn/dp,Simatic S7-1500 Cpu 1518-4 Pn/dp,Simatic S7-1500 Cpu 1518-4 Pn/dp Mfp,Simatic S7-1500 Cpu 1518f-4 Pn/dp,Simatic S7-1500 Cpu 1518f-4 Pn/dp Mfp,Simatic S7-1500 Cpu 1518hf-4 Pn,Simatic S7-1500 Cpu 1518t-4 Pn/dp,Simatic S7-1500 Cpu 1518tf-4 Pn/dp,Simatic S7-1500 Cpu S7-1518-4 Pn/dp Odk,Simatic S7-1500 Cpu S7-1518f-4 Pn/dp Odk,Simatic S7-1500 Et 200pro: Cpu 1513pro F-2 Pn,Simatic S7-1500 Et 200pro: Cpu 1513pro-2 Pn,Simatic S7-1500 Et 200pro: Cpu 1516pro F-2 Pn,Simatic S7-1500 Et 200pro: Cpu 1516pro-2 Pn,Simatic S7-1500 Software Controller V2,Simatic S7-plcsim Advanced,Siplus Et 200sp Cpu 1510sp F-1 Pn,Siplus Et 200sp Cpu 1510sp F-1 Pn Rail,Siplus Et 200sp Cpu 1510sp-1 Pn,Siplus Et 200sp Cpu 1510sp-1 Pn Rail,Siplus Et 200sp Cpu 1512sp F-1 Pn,Siplus Et 200sp Cpu 1512sp F-1 Pn Rail,Siplus Et 200sp Cpu 1512sp-1 Pn,Siplus Et 200sp Cpu 1512sp-1 Pn Rail,Siplus S7-1500 Cpu 1511-1 Pn,Siplus S7-1500 Cpu 1511-1 Pn T1 Rail,Siplus S7-1500 Cpu 1511-1 Pn Tx Rail,Siplus S7-1500 Cpu 1511f-1 Pn,Siplus S7-1500 Cpu 1513-1 Pn,Siplus S7-1500 Cpu 1513f-1 Pn,Siplus S7-1500 Cpu 1515f-2 Pn,Siplus S7-1500 Cpu 1515f-2 Pn Rail,Siplus S7-1500 Cpu 1515f-2 Pn T2 Rail,Siplus S7-1500 Cpu 1515r-2 Pn,Siplus S7-1500 Cpu 1515r-2 Pn Tx Rail,Siplus S7-1500 Cpu 1516-3 Pn/dp,Siplus S7-1500 Cpu 1516-3 Pn/dp Rail,Siplus S7-1500 Cpu 1516-3 Pn/dp Tx Rail,Siplus S7-1500 Cpu 1516f-3 Pn/dp,Siplus S7-1500 Cpu 1516f-3 Pn/dp Rail,Siplus S7-1500 Cpu 1517h-3 Pn,Siplus S7-1500 Cpu 1518-4 Pn/dp,Siplus S7-1500 Cpu 1518-4 Pn/dp Mfp,Siplus S7-1500 Cpu 1518f-4 Pn/dp,Siplus S7-1500 Cpu 1518hf-4 Pn,Siplus Tim 1531 Irc,Tim 1531 Irc",4.9,MEDIUM,0.0004400000034365803,false,,false,false,false,,false,false,2022-12-13T00:00:00.000Z,0 CVE-2022-30694,https://securityvulnerability.io/vulnerability/CVE-2022-30694,Cross-Site Request Forgery Vulnerability in Siemens Web Services,"An issue in the login endpoint of Siemens web services permits inadequate origin checking, allowing authenticated remote attackers to potentially exploit this weakness. By leveraging this vulnerability, attackers can orchestrate cross-site request forgery (CSRF) attacks, which could enable them to track the activities of legitimate users without their consent.",Siemens,"Simatic Drive Controller Cpu 1504d Tf,Simatic Drive Controller Cpu 1507d Tf,Simatic Et 200pro Im154-8 Pn/dp Cpu,Simatic Et 200pro Im154-8f Pn/dp Cpu,Simatic Et 200pro Im154-8fx Pn/dp Cpu,Simatic Et 200s Im151-8 Pn/dp Cpu,Simatic Et 200s Im151-8f Pn/dp Cpu,Simatic Et 200sp Open Controller Cpu 1515sp Pc2 (incl. Siplus Variants),Simatic Pc Station,Simatic S7-1200 Cpu Family (incl. Siplus Variants),Simatic S7-1500 Cpu 1510sp F-1 Pn,Simatic S7-1500 Cpu 1510sp-1 Pn,Simatic S7-1500 Cpu 1511-1 Pn,Simatic S7-1500 Cpu 1511c-1 Pn,Simatic S7-1500 Cpu 1511f-1 Pn,Simatic S7-1500 Cpu 1511t-1 Pn,Simatic S7-1500 Cpu 1511tf-1 Pn,Simatic S7-1500 Cpu 1512c-1 Pn,Simatic S7-1500 Cpu 1512sp F-1 Pn,Simatic S7-1500 Cpu 1512sp-1 Pn,Simatic S7-1500 Cpu 1513-1 Pn,Simatic S7-1500 Cpu 1513f-1 Pn,Simatic S7-1500 Cpu 1513r-1 Pn,Simatic S7-1500 Cpu 1515-2 Pn,Simatic S7-1500 Cpu 1515f-2 Pn,Simatic S7-1500 Cpu 1515r-2 Pn,Simatic S7-1500 Cpu 1515t-2 Pn,Simatic S7-1500 Cpu 1515tf-2 Pn,Simatic S7-1500 Cpu 1516-3 Pn/dp,Simatic S7-1500 Cpu 1516f-3 Pn/dp,Simatic S7-1500 Cpu 1516t-3 Pn/dp,Simatic S7-1500 Cpu 1516tf-3 Pn/dp,Simatic S7-1500 Cpu 1517-3 Pn/dp,Simatic S7-1500 Cpu 1517f-3 Pn/dp,Simatic S7-1500 Cpu 1517h-3 Pn,Simatic S7-1500 Cpu 1517t-3 Pn/dp,Simatic S7-1500 Cpu 1517tf-3 Pn/dp,Simatic S7-1500 Cpu 1518-4 Pn/dp,Simatic S7-1500 Cpu 1518-4 Pn/dp Mfp,Simatic S7-1500 Cpu 1518f-4 Pn/dp,Simatic S7-1500 Cpu 1518f-4 Pn/dp Mfp,Simatic S7-1500 Cpu 1518hf-4 Pn,Simatic S7-1500 Cpu 1518t-4 Pn/dp,Simatic S7-1500 Cpu 1518tf-4 Pn/dp,Simatic S7-1500 Cpu S7-1518-4 Pn/dp Odk,Simatic S7-1500 Cpu S7-1518f-4 Pn/dp Odk,Simatic S7-1500 Et 200pro: Cpu 1513pro F-2 Pn,Simatic S7-1500 Et 200pro: Cpu 1513pro-2 Pn,Simatic S7-1500 Et 200pro: Cpu 1516pro F-2 Pn,Simatic S7-1500 Et 200pro: Cpu 1516pro-2 Pn,Simatic S7-1500 Software Controller V2,Simatic S7-300 Cpu 314c-2 Pn/dp,Simatic S7-300 Cpu 315-2 Pn/dp,Simatic S7-300 Cpu 315f-2 Pn/dp,Simatic S7-300 Cpu 315t-3 Pn/dp,Simatic S7-300 Cpu 317-2 Pn/dp,Simatic S7-300 Cpu 317f-2 Pn/dp,Simatic S7-300 Cpu 317t-3 Pn/dp,Simatic S7-300 Cpu 317tf-3 Pn/dp,Simatic S7-300 Cpu 319-3 Pn/dp,Simatic S7-300 Cpu 319f-3 Pn/dp,Simatic S7-400 Pn/dp V6 Cpu Family (incl. Siplus Variants),Simatic S7-400 Pn/dp V7 Cpu Family (incl. Siplus Variants),Simatic S7-plcsim Advanced,Simatic Wincc Runtime Advanced,Sinumerik One,Siplus Et 200s Im151-8 Pn/dp Cpu,Siplus Et 200s Im151-8f Pn/dp Cpu,Siplus Et 200sp Cpu 1510sp F-1 Pn,Siplus Et 200sp Cpu 1510sp F-1 Pn Rail,Siplus Et 200sp Cpu 1510sp-1 Pn,Siplus Et 200sp Cpu 1510sp-1 Pn Rail,Siplus Et 200sp Cpu 1512sp F-1 Pn,Siplus Et 200sp Cpu 1512sp F-1 Pn Rail,Siplus Et 200sp Cpu 1512sp-1 Pn,Siplus Et 200sp Cpu 1512sp-1 Pn Rail,Siplus S7-1500 Cpu 1511-1 Pn,Siplus S7-1500 Cpu 1511-1 Pn T1 Rail,Siplus S7-1500 Cpu 1511-1 Pn Tx Rail,Siplus S7-1500 Cpu 1511f-1 Pn,Siplus S7-1500 Cpu 1513-1 Pn,Siplus S7-1500 Cpu 1513f-1 Pn,Siplus S7-1500 Cpu 1515f-2 Pn,Siplus S7-1500 Cpu 1515f-2 Pn Rail,Siplus S7-1500 Cpu 1515f-2 Pn T2 Rail,Siplus S7-1500 Cpu 1515r-2 Pn,Siplus S7-1500 Cpu 1515r-2 Pn Tx Rail,Siplus S7-1500 Cpu 1516-3 Pn/dp,Siplus S7-1500 Cpu 1516-3 Pn/dp Rail,Siplus S7-1500 Cpu 1516-3 Pn/dp Tx Rail,Siplus S7-1500 Cpu 1516f-3 Pn/dp,Siplus S7-1500 Cpu 1516f-3 Pn/dp Rail,Siplus S7-1500 Cpu 1517h-3 Pn,Siplus S7-1500 Cpu 1518-4 Pn/dp,Siplus S7-1500 Cpu 1518-4 Pn/dp Mfp,Siplus S7-1500 Cpu 1518f-4 Pn/dp,Siplus S7-1500 Cpu 1518hf-4 Pn,Siplus S7-300 Cpu 314c-2 Pn/dp,Siplus S7-300 Cpu 315-2 Pn/dp,Siplus S7-300 Cpu 315f-2 Pn/dp,Siplus S7-300 Cpu 317-2 Pn/dp,Siplus S7-300 Cpu 317f-2 Pn/dp",6.5,MEDIUM,0.0004600000102072954,false,,false,false,false,,false,false,2022-11-08T00:00:00.000Z,0 CVE-2022-38465,https://securityvulnerability.io/vulnerability/CVE-2022-38465,Vulnerability in SIMATIC Drive Controllers and Related Products by Siemens,"A cryptographic vulnerability affects several product families within the Siemens SIMATIC range, most notably the SIMATIC Drive Controllers and various CPUs. The issue stems from inadequate protection of the built-in global private key, which is intended to secure sensitive configuration data and facilitate communications. This flaw permits potential offline attacks by enabling malicious actors to deduce the private key by exploiting a single compromised unit. Once obtained, the private key could lead to unauthorized access to confidential configuration data and disrupt legacy communications with PG/PC and HMI systems.",Siemens,"Simatic Drive Controller Family,Simatic Et 200sp Open Controller Cpu 1515sp Pc (incl. Siplus Variants),Simatic Et 200sp Open Controller Cpu 1515sp Pc2 (incl. Siplus Variants),Simatic S7-1200 Cpu Family (incl. Siplus Variants),Simatic S7-1500 Cpu Family (incl. Related Et200 Cpus And Siplus Variants),Simatic S7-1500 Software Controller,Simatic S7-plcsim Advanced,Sinumerik Mc,Sinumerik One",9.3,CRITICAL,0.0004400000034365803,false,,false,false,false,,false,false,2022-10-11T00:00:00.000Z,0 CVE-2021-37205,https://securityvulnerability.io/vulnerability/CVE-2021-37205,,"A vulnerability has been identified in SIMATIC Drive Controller family (All versions >= V2.9.2 < V2.9.4), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions >= V21.9 < V21.9.4), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions >= V4.5.0 < V4.5.2), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions >= V2.9.2 < V2.9.4), SIMATIC S7-1500 Software Controller (All versions >= V21.9 < V21.9.4), SIMATIC S7-PLCSIM Advanced (All versions >= V4.0 < V4.0 SP1), SIPLUS TIM 1531 IRC (All versions < V2.3.6), TIM 1531 IRC (All versions < V2.3.6). An unauthenticated attacker could cause a denial-of-service condition in a PLC when sending specially prepared packets over port 102/tcp. A restart of the affected device is needed to restore normal operations.",Siemens,"Simatic Drive Controller Family,Simatic Et 200sp Open Controller Cpu 1515sp Pc2 (incl. Siplus Variants),Simatic S7-1200 Cpu Family (incl. Siplus Variants),Simatic S7-1500 Cpu Family (incl. Related Et200 Cpus And Siplus Variants),Simatic S7-1500 Software Controller,Simatic S7-plcsim Advanced,Siplus Tim 1531 Irc,Tim 1531 Irc",7.5,HIGH,0.0004400000034365803,false,,false,false,false,,false,false,2022-02-09T15:16:57.000Z,0 CVE-2021-37204,https://securityvulnerability.io/vulnerability/CVE-2021-37204,,"A vulnerability has been identified in SIMATIC Drive Controller family (All versions < V2.9.2), SIMATIC Drive Controller family (All versions >= V2.9.2 < V2.9.4), SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants) (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions < V21.9), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions >= V21.9 < V21.9.4), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 Ready4Linux (All versions), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions < V4.5.0), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions >= V4.5.0 < V4.5.2), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions < V2.9.2), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions >= V2.9.2 < V2.9.4), SIMATIC S7-1500 Software Controller (All versions < V21.9), SIMATIC S7-1500 Software Controller (All versions >= V21.9 < V21.9.4), SIMATIC S7-PLCSIM Advanced (All versions < V4.0), SIMATIC S7-PLCSIM Advanced (All versions >= V4.0 < V4.0 SP1), SIPLUS TIM 1531 IRC (All versions < V2.3.6), TIM 1531 IRC (All versions < V2.3.6). An unauthenticated attacker could cause a denial-of-service condition in a PLC when sending specially prepared packet over port 102/tcp. A restart of the affected device is needed to restore normal operations.",Siemens,"Simatic Drive Controller Family,Simatic Et 200sp Open Controller Cpu 1515sp Pc (incl. Siplus Variants),Simatic Et 200sp Open Controller Cpu 1515sp Pc2 (incl. Siplus Variants),Simatic Et 200sp Open Controller Cpu 1515sp Pc2 Ready4linux,Simatic S7-1200 Cpu Family (incl. Siplus Variants),Simatic S7-1500 Cpu Family (incl. Related Et200 Cpus And Siplus Variants),Simatic S7-1500 Software Controller,Simatic S7-plcsim Advanced,Siplus Tim 1531 Irc,Tim 1531 Irc",7.5,HIGH,0.0004400000034365803,false,,false,false,false,,false,false,2022-02-09T15:16:56.000Z,0 CVE-2021-37185,https://securityvulnerability.io/vulnerability/CVE-2021-37185,,"A vulnerability has been identified in SIMATIC Drive Controller family (All versions >= V2.9.2 < V2.9.4), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions >= V21.9 < V21.9.4), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions >= V4.5.0 < V4.5.2), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions >= V2.9.2 < V2.9.4), SIMATIC S7-1500 Software Controller (All versions >= V21.9 < V21.9.4), SIMATIC S7-PLCSIM Advanced (All versions >= V4.0 < V4.0 SP1), SIPLUS TIM 1531 IRC (All versions < V2.3.6), TIM 1531 IRC (All versions < V2.3.6). An unauthenticated attacker could cause a denial-of-service condition in a PLC when sending specially prepared packets over port 102/tcp. A restart of the affected device is needed to restore normal operations.",Siemens,"Simatic Drive Controller Family,Simatic Et 200sp Open Controller Cpu 1515sp Pc2 (incl. Siplus Variants),Simatic S7-1200 Cpu Family (incl. Siplus Variants),Simatic S7-1500 Cpu Family (incl. Related Et200 Cpus And Siplus Variants),Simatic S7-1500 Software Controller,Simatic S7-plcsim Advanced,Siplus Tim 1531 Irc,Tim 1531 Irc",7.5,HIGH,0.0004400000034365803,false,,false,false,false,,false,false,2022-02-09T15:16:44.000Z,0 CVE-2020-28397,https://securityvulnerability.io/vulnerability/CVE-2020-28397,,"A vulnerability has been identified in SIMATIC Drive Controller family (All versions < V2.9.2), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions < V21.9), SIMATIC S7 PLCSIM Advanced (All versions > V2 < V4), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (Version V4.4), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions > V2.5 < V2.9.2), SIMATIC S7-1500 Software Controller (All versions > V2.5 < V21.9), TIM 1531 IRC (incl. SIPLUS NET variants) (Version V2.1). Due to an incorrect authorization check in the affected component, an attacker could extract information about access protected PLC program variables over port 102/tcp from an affected device when reading multiple attributes at once.",Siemens,"Simatic Drive Controller Family,Simatic Et 200sp Open Controller Cpu 1515sp Pc2 (incl. Siplus Variants),Simatic S7 Plcsim Advanced,Simatic S7-1200 Cpu Family (incl. Siplus Variants),Simatic S7-1500 Cpu Family (incl. Related Et200 Cpus And Siplus Variants),Simatic S7-1500 Software Controller,Tim 1531 Irc (incl. Siplus Net Variants)",5.3,MEDIUM,0.0008399999933317304,false,,false,false,false,,false,false,2021-08-10T10:35:23.000Z,0 CVE-2020-15782,https://securityvulnerability.io/vulnerability/CVE-2020-15782,,"A vulnerability has been identified in SIMATIC Drive Controller family (All versions < V2.9.2), SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants) (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions < V21.9), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions < V4.5.0), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions < V2.9.2), SIMATIC S7-1500 Software Controller (All versions < V21.9), SIMATIC S7-PLCSIM Advanced (All versions < V4.0), SINAMICS PERFECT HARMONY GH180 Drives (Drives manufactured before 2021-08-13), SINUMERIK MC (All versions < V6.15), SINUMERIK ONE (All versions < V6.15). Affected devices are vulnerable to a memory protection bypass through a specific operation. A remote unauthenticated attacker with network access to port 102/tcp could potentially write arbitrary data and code to protected memory areas or read sensitive data to launch further attacks.",Siemens,"Simatic Drive Controller Family,Simatic Et 200sp Open Controller Cpu 1515sp Pc (incl. Siplus Variants),Simatic Et 200sp Open Controller Cpu 1515sp Pc2 (incl. Siplus Variants),Simatic S7-1200 Cpu Family (incl. Siplus Variants),Simatic S7-1500 Cpu Family (incl. Related Et200 Cpus And Siplus Variants),Simatic S7-1500 Software Controller,Simatic S7-plcsim Advanced,Sinamics Perfect Harmony Gh180 Drives,Sinumerik Mc,Sinumerik One",9.8,CRITICAL,0.004569999873638153,false,,false,false,false,,false,false,2021-05-28T16:10:10.000Z,0 CVE-2019-19300,https://securityvulnerability.io/vulnerability/CVE-2019-19300,,"A vulnerability has been identified in Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200, Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200P, KTK ATE530S, SIDOOR ATD430W, SIDOOR ATE530S COATED, SIDOOR ATE531S, SIMATIC ET 200AL IM 157-1 PN (6ES7157-1AB00-0AB0), SIMATIC ET 200MP IM 155-5 PN HF (6ES7155-5AA00-0AC0), SIMATIC ET 200pro IM 154-8 PN/DP CPU (6ES7154-8AB01-0AB0), SIMATIC ET 200pro IM 154-8F PN/DP CPU (6ES7154-8FB01-0AB0), SIMATIC ET 200pro IM 154-8FX PN/DP CPU (6ES7154-8FX00-0AB0), SIMATIC ET 200S IM 151-8 PN/DP CPU (6ES7151-8AB01-0AB0), SIMATIC ET 200S IM 151-8F PN/DP CPU (6ES7151-8FB01-0AB0), SIMATIC ET 200SP IM 155-6 MF HF (6ES7155-6MU00-0CN0), SIMATIC ET 200SP IM 155-6 PN HA (incl. SIPLUS variants), SIMATIC ET 200SP IM 155-6 PN HF (6ES7155-6AU00-0CN0), SIMATIC ET 200SP IM 155-6 PN/2 HF (6ES7155-6AU01-0CN0), SIMATIC ET 200SP IM 155-6 PN/3 HF (6ES7155-6AU30-0CN0), SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants), SIMATIC ET200ecoPN, AI 8xRTD/TC, M12-L (6ES7144-6JF00-0BB0), SIMATIC ET200ecoPN, CM 4x IO-Link, M12-L (6ES7148-6JE00-0BB0), SIMATIC ET200ecoPN, CM 8x IO-Link, M12-L (6ES7148-6JG00-0BB0), SIMATIC ET200ecoPN, CM 8x IO-Link, M12-L (6ES7148-6JJ00-0BB0), SIMATIC ET200ecoPN, DI 16x24VDC, M12-L (6ES7141-6BH00-0BB0), SIMATIC ET200ecoPN, DI 8x24VDC, M12-L (6ES7141-6BG00-0BB0), SIMATIC ET200ecoPN, DIQ 16x24VDC/2A, M12-L (6ES7143-6BH00-0BB0), SIMATIC ET200ecoPN, DQ 8x24VDC/0,5A, M12-L (6ES7142-6BG00-0BB0), SIMATIC ET200ecoPN, DQ 8x24VDC/2A, M12-L (6ES7142-6BR00-0BB0), SIMATIC MICRO-DRIVE PDC, SIMATIC PN/MF Coupler (6ES7158-3MU10-0XA0), SIMATIC PN/PN Coupler (6ES7158-3AD10-0XA0), SIMATIC S7-1200 CPU family (incl. SIPLUS variants), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants), SIMATIC S7-1500 Software Controller, SIMATIC S7-300 CPU 314C-2 PN/DP (6ES7314-6EH04-0AB0), SIMATIC S7-300 CPU 315-2 PN/DP (6ES7315-2EH14-0AB0), SIMATIC S7-300 CPU 315F-2 PN/DP (6ES7315-2FJ14-0AB0), SIMATIC S7-300 CPU 315T-3 PN/DP (6ES7315-7TJ10-0AB0), SIMATIC S7-300 CPU 317-2 PN/DP (6ES7317-2EK14-0AB0), SIMATIC S7-300 CPU 317F-2 PN/DP (6ES7317-2FK14-0AB0), SIMATIC S7-300 CPU 317T-3 PN/DP (6ES7317-7TK10-0AB0), SIMATIC S7-300 CPU 317TF-3 PN/DP (6ES7317-7UL10-0AB0), SIMATIC S7-300 CPU 319-3 PN/DP (6ES7318-3EL01-0AB0), SIMATIC S7-300 CPU 319F-3 PN/DP (6ES7318-3FL01-0AB0), SIMATIC S7-400 H V6 and below CPU family (incl. SIPLUS variants), SIMATIC S7-400 PN/DP V7 CPU family (incl. SIPLUS variants), SIMATIC S7-410 V10 CPU family (incl. SIPLUS variants), SIMATIC S7-410 V8 CPU family (incl. SIPLUS variants), SIMATIC TDC CP51M1, SIMATIC TDC CPU555, SIMATIC WinAC RTX 2010 (6ES7671-0RC08-0YA0), SIMATIC WinAC RTX F 2010 (6ES7671-1RC08-0YA0), SINAMICS S/G Control Unit w. PROFINET, SIPLUS ET 200MP IM 155-5 PN HF (6AG1155-5AA00-2AC0), SIPLUS ET 200MP IM 155-5 PN HF (6AG1155-5AA00-7AC0), SIPLUS ET 200MP IM 155-5 PN HF T1 RAIL (6AG2155-5AA00-1AC0), SIPLUS ET 200S IM 151-8 PN/DP CPU (6AG1151-8AB01-7AB0), SIPLUS ET 200S IM 151-8F PN/DP CPU (6AG1151-8FB01-2AB0), SIPLUS ET 200SP IM 155-6 PN HF (6AG1155-6AU00-2CN0), SIPLUS ET 200SP IM 155-6 PN HF (6AG1155-6AU00-4CN0), SIPLUS ET 200SP IM 155-6 PN HF (6AG1155-6AU01-2CN0), SIPLUS ET 200SP IM 155-6 PN HF (6AG1155-6AU01-7CN0), SIPLUS ET 200SP IM 155-6 PN HF T1 RAIL (6AG2155-6AU00-1CN0), SIPLUS ET 200SP IM 155-6 PN HF T1 RAIL (6AG2155-6AU01-1CN0), SIPLUS ET 200SP IM 155-6 PN HF TX RAIL (6AG2155-6AU01-4CN0), SIPLUS NET PN/PN Coupler (6AG2158-3AD10-4XA0), SIPLUS S7-300 CPU 314C-2 PN/DP (6AG1314-6EH04-7AB0), SIPLUS S7-300 CPU 315-2 PN/DP (6AG1315-2EH14-7AB0), SIPLUS S7-300 CPU 315F-2 PN/DP (6AG1315-2FJ14-2AB0), SIPLUS S7-300 CPU 317-2 PN/DP (6AG1317-2EK14-7AB0), SIPLUS S7-300 CPU 317F-2 PN/DP (6AG1317-2FK14-2AB0). The Interniche-based TCP Stack can be forced to make very expensive calls for every incoming packet which can lead to a denial of service.",Siemens,"Development/evaluation Kits For Profinet Io: Ek-ertec 200,Development/evaluation Kits For Profinet Io: Ek-ertec 200p,Ktk Ate530s,Sidoor Atd430w,Sidoor Ate530s Coated,Sidoor Ate531s,Simatic Et 200al Im 157-1 Pn,Simatic Et 200mp Im 155-5 Pn Hf,Simatic Et 200pro Im 154-8 Pn/dp Cpu,Simatic Et 200pro Im 154-8f Pn/dp Cpu,Simatic Et 200pro Im 154-8fx Pn/dp Cpu,Simatic Et 200s Im 151-8 Pn/dp Cpu,Simatic Et 200s Im 151-8f Pn/dp Cpu,Simatic Et 200sp Im 155-6 Mf Hf,Simatic Et 200sp Im 155-6 Pn Ha (incl. Siplus Variants),Simatic Et 200sp Im 155-6 Pn Hf,Simatic Et 200sp Im 155-6 Pn/2 Hf,Simatic Et 200sp Im 155-6 Pn/3 Hf,Simatic Et 200sp Open Controller Cpu 1515sp Pc (incl. Siplus Variants),Simatic Et 200sp Open Controller Cpu 1515sp Pc2 (incl. Siplus Variants),Simatic Et200ecopn, Ai 8xrtd/tc, M12-l,Simatic Et200ecopn, Cm 4x Io-link, M12-l,Simatic Et200ecopn, Cm 8x Io-link, M12-l,Simatic Et200ecopn, Di 16x24vdc, M12-l,Simatic Et200ecopn, Di 8x24vdc, M12-l,Simatic Et200ecopn, Diq 16x24vdc/2a, M12-l,Simatic Et200ecopn, Dq 8x24vdc/0,5a, M12-l,Simatic Et200ecopn, Dq 8x24vdc/2a, M12-l,Simatic Micro-drive Pdc,Simatic Pn/mf Coupler,Simatic Pn/pn Coupler,Simatic S7-1200 Cpu Family (incl. Siplus Variants),Simatic S7-1500 Cpu Family (incl. Related Et200 Cpus And Siplus Variants),Simatic S7-1500 Software Controller,Simatic S7-300 Cpu 314c-2 Pn/dp,Simatic S7-300 Cpu 315-2 Pn/dp,Simatic S7-300 Cpu 315f-2 Pn/dp,Simatic S7-300 Cpu 315t-3 Pn/dp,Simatic S7-300 Cpu 317-2 Pn/dp,Simatic S7-300 Cpu 317f-2 Pn/dp,Simatic S7-300 Cpu 317t-3 Pn/dp,Simatic S7-300 Cpu 317tf-3 Pn/dp,Simatic S7-300 Cpu 319-3 Pn/dp,Simatic S7-300 Cpu 319f-3 Pn/dp,Simatic S7-400 H V6 and Below cpu Family (incl. Siplus Variants),Simatic S7-400 Pn/dp V7 Cpu Family (incl. Siplus Variants),Simatic S7-410 V10 Cpu Family (incl. Siplus Variants),Simatic S7-410 V8 Cpu Family (incl. Siplus Variants),Simatic Tdc Cp51m1,Simatic Tdc Cpu555,Simatic Winac Rtx 2010,Simatic Winac Rtx F 2010,Sinamics S/g Control Unit W. Profinet,Siplus Et 200mp Im 155-5 Pn Hf,Siplus Et 200mp Im 155-5 Pn Hf T1 Rail,Siplus Et 200s Im 151-8 Pn/dp Cpu,Siplus Et 200s Im 151-8f Pn/dp Cpu,Siplus Et 200sp Im 155-6 Pn Hf,Siplus Et 200sp Im 155-6 Pn Hf T1 Rail,Siplus Et 200sp Im 155-6 Pn Hf Tx Rail,Siplus Net Pn/pn Coupler,Siplus S7-300 Cpu 314c-2 Pn/dp,Siplus S7-300 Cpu 315-2 Pn/dp,Siplus S7-300 Cpu 315f-2 Pn/dp,Siplus S7-300 Cpu 317-2 Pn/dp,Siplus S7-300 Cpu 317f-2 Pn/dp",7.5,HIGH,0.0011599999852478504,false,,false,false,false,,false,false,2020-04-14T00:00:00.000Z,0 CVE-2019-10943,https://securityvulnerability.io/vulnerability/CVE-2019-10943,,"A vulnerability has been identified in SIMATIC Drive Controller family (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants) (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions < V20.8), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions >= V20.8), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions < V4.4.0), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions >= V4.4.0), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions < V2.8.1), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions >= V2.8.1), SIMATIC S7-1500 Software Controller (All versions < V20.8), SIMATIC S7-1500 Software Controller (All versions >= V20.8), SIMATIC S7-PLCSIM Advanced (All versions < V3.0), SIMATIC S7-PLCSIM Advanced (All versions >= V3.0). An attacker with network access to port 102/tcp could potentially modify the user program on the PLC in a way that the running code is different from the source code which is stored on the device. An attacker must have network access to affected devices and must be able to perform changes to the user program. The vulnerability could impact the perceived integrity of the user program stored on the CPU. An engineer that tries to obtain the code of the user program running on the device, can receive different source code that is not actually running on the device.",Siemens,"Simatic Drive Controller Family,Simatic Et 200sp Open Controller Cpu 1515sp Pc (incl. Siplus Variants),Simatic Et 200sp Open Controller Cpu 1515sp Pc2 (incl. Siplus Variants),Simatic S7-1200 Cpu Family (incl. Siplus Variants),Simatic S7-1500 Cpu Family (incl. Related Et200 Cpus And Siplus Variants),Simatic S7-1500 Software Controller,Simatic S7-plcsim Advanced",7.5,HIGH,0.0008399999933317304,false,,false,false,false,,false,false,2019-08-13T18:55:57.000Z,0