cve,link,title,description,vendor,products,score,severity,epss,cisa,cisa_published,article,ransomware,exploited,poc,trended,trended_no_1,published,trended_score CVE-2024-35783,https://securityvulnerability.io/vulnerability/CVE-2024-35783,Elevated Privileges Vulnerability Affects Siemens' Industrial Automation Products,"A vulnerability affects various Siemens SIMATIC products, specifically allowing the database server to operate with elevated privileges. This situation provides a potential opportunity for authenticated attackers to execute arbitrary operating system commands, posing a significant security risk to the affected systems. Products including SIMATIC BATCH, SIMATIC Information Server, and multiple versions of SIMATIC WinCC have been identified as vulnerable. Proper mitigation measures should be employed to safeguard against potential exploitation.",Siemens,"Simatic Batch V9.1,Simatic Information Server 2020,Simatic Information Server 2022,Simatic Pcs 7 V9.1,Simatic Process Historian 2020,Simatic Process Historian 2022,Simatic Wincc Runtime Professional V18,Simatic Wincc Runtime Professional V19,Simatic Wincc V7.4,Simatic Wincc V7.5,Simatic Wincc V8.0",9.1,CRITICAL,0.0004299999854993075,false,,false,false,false,,false,false,2024-09-10T09:36:32.225Z,0 CVE-2024-30321,https://securityvulnerability.io/vulnerability/CVE-2024-30321,Information Disclosure in Siemens SIMATIC Products,"A vulnerability has been identified in specific versions of Siemens SIMATIC PCS 7, WinCC Runtime Professional, and WinCC products. The issue arises due to improper handling of certain requests within their web applications, potentially allowing unauthenticated remote attackers to access sensitive information, such as user credentials. This poses significant risks to organizations utilizing these systems, emphasizing the need for immediate updates to the latest patches.",Siemens,"Simatic Pcs 7 V9.1,Simatic Wincc Runtime Professional V18,Simatic Wincc Runtime Professional V19,Simatic Wincc V7.4,Simatic Wincc V7.5,Simatic Wincc V8.0",5.9,MEDIUM,0.0004299999854993075,false,,false,false,false,,false,false,2024-07-09T12:15:00.000Z,0 CVE-2022-45147,https://securityvulnerability.io/vulnerability/CVE-2022-45147,Serious Vulnerability Affects Siemens' SIMATIC PCS NEO and STEP 7 Applications,"A vulnerability exists in Siemens SIMATIC PCS neo and STEP 7 products, where improper restrictions on the .NET BinaryFormatter during deserialization of user-controllable input could lead to type confusion. This flaw allows an attacker to execute arbitrary code within the affected applications. For more details, refer to the official Siemens CERT portal.",Siemens,"Simatic Pcs Neo V4.0,Simatic Step 7 V16,Simatic Step 7 V17,Simatic Step 7 V18",7.8,HIGH,0.0004299999854993075,false,,false,false,false,,false,false,2024-07-09T12:04:22.545Z,0 CVE-2023-46280,https://securityvulnerability.io/vulnerability/CVE-2023-46280,Out of Bounds Read Vulnerability in SIMATIC and TIA Portal Products by Siemens,"An out of bounds read vulnerability has been identified in multiple Siemens products, including the SIMATIC and TIA Portal series. This flaw can potentially lead to the crashing of the Windows kernel, resulting in a Blue Screen of Death (BSOD) error. Attackers could exploit this vulnerability to destabilize systems, impacting operational efficiency and safety within industrial environments. It is crucial for users of these products to be aware of this vulnerability and to implement necessary mitigations as outlined by Siemens.",Siemens,"Security Configuration Tool (sct),Simatic Automation Tool,Simatic Batch V9.1,Simatic Net Pc Software V16,Simatic Net Pc Software V17,Simatic Net Pc Software V18,Simatic Net Pc Software V19,Simatic Pcs 7 V9.1,Simatic Pdm V9.2,Simatic Route Control V9.1,Simatic S7-pct,Simatic Step 7 V5,Simatic Wincc Oa V3.17,Simatic Wincc Oa V3.18,Simatic Wincc Oa V3.19,Simatic Wincc Runtime Advanced,Simatic Wincc Runtime Professional V16,Simatic Wincc Runtime Professional V17,Simatic Wincc Runtime Professional V18,Simatic Wincc Runtime Professional V19,Simatic Wincc V7.4,Simatic Wincc V7.5,Simatic Wincc V8.0,Sinamics Startdrive,Sinec Nms,Sinumerik One Virtual,Sinumerik Plc Programming Tool,Tia Portal Cloud Connector,Totally Integrated Automation Portal (tia Portal) V15.1,Totally Integrated Automation Portal (tia Portal) V16,Totally Integrated Automation Portal (tia Portal) V17,Totally Integrated Automation Portal (tia Portal) V18,Totally Integrated Automation Portal (tia Portal) V19",6.5,MEDIUM,0.00044999999227002263,false,,false,false,false,,false,false,2024-05-14T10:01:52.069Z,0 CVE-2023-50821,https://securityvulnerability.io/vulnerability/CVE-2023-50821,Input Validation Flaw in SIMATIC PCS 7 and WinCC Runtime Products by Siemens,"An input validation flaw in various Siemens SIMATIC PCS 7 and WinCC Runtime products could be exploited by attackers. This vulnerability arises from improper handling of user inputs within the login dialog box, allowing for a potential persistent denial of service condition. Users are advised to review and update the affected products to mitigate the risk associated with this vulnerability.",Siemens,"Simatic Pcs 7 V9.1,Simatic Wincc Runtime Professional V17,Simatic Wincc Runtime Professional V18,Simatic Wincc Runtime Professional V19,Simatic Wincc V7.5,Simatic Wincc V8.0",6.2,MEDIUM,0.0004299999854993075,false,,false,false,false,,false,false,2024-04-09T08:34:35.452Z,0 CVE-2023-48364,https://securityvulnerability.io/vulnerability/CVE-2023-48364,Remote Procedure Call Vulnerability in OpenPCS and SIMATIC Products by Siemens,"A vulnerability exists in certain Siemens OpenPCS and SIMATIC products due to improper handling of malformed Remote Procedure Call (RPC) messages. This oversight could allow an attacker to exploit the vulnerability, leading to a denial of service condition in the RPC server, thereby impacting the availability and functionality of the affected systems. It is crucial for users to apply the updates provided by Siemens to mitigate potential risks associated with this vulnerability.",Siemens,"Openpcs 7 V9.1,Simatic Batch V9.1,Simatic Pcs 7 V9.1,Simatic Route Control V9.1,Simatic Wincc Runtime Professional V18,Simatic Wincc Runtime Professional V19,Simatic Wincc V7.4,Simatic Wincc V7.5,Simatic Wincc V8.0",6.5,MEDIUM,0.0004400000034365803,false,,false,false,false,,false,false,2024-02-13T08:59:56.648Z,0 CVE-2023-48363,https://securityvulnerability.io/vulnerability/CVE-2023-48363,Remote Procedure Call Vulnerability in Siemens OpenPCS and SIMATIC Products,"A vulnerability exists in certain versions of Siemens OpenPCS and SIMATIC products due to improper handling of specific unorganized Remote Procedure Call (RPC) messages. This flaw can be exploited by an attacker to trigger a denial of service condition in the RPC server, potentially disrupting operations across affected systems. Timely updates to the latest service packs are recommended to mitigate this risk.",Siemens,"Openpcs 7 V9.1,Simatic Batch V9.1,Simatic Pcs 7 V9.1,Simatic Route Control V9.1,Simatic Wincc Runtime Professional V18,Simatic Wincc Runtime Professional V19,Simatic Wincc V7.4,Simatic Wincc V7.5,Simatic Wincc V8.0",6.5,MEDIUM,0.0004400000034365803,false,,false,false,false,,false,false,2024-02-13T08:59:55.432Z,0 CVE-2023-28831,https://securityvulnerability.io/vulnerability/CVE-2023-28831,Integer Overflow Issue in Siemens OPC UA Implementations,"The OPC UA implementations in Siemens products harbor an integer overflow vulnerability that can lead to an infinite loop during the certificate validation process. This condition could be exploited by an unauthenticated remote attacker utilizing a specially crafted certificate, resulting in a denial of service that impacts application availability and reliability.",Siemens,"Simatic Braumat,Simatic Cloud Connect 7 Cc712,Simatic Cloud Connect 7 Cc716,Simatic Comfort/mobile Rt,Simatic Drive Controller Cpu 1504d Tf,Simatic Drive Controller Cpu 1507d Tf,Simatic Et 200sp Open Controller Cpu 1515sp Pc2 (incl. Siplus Variants),Simatic Ipc Diagmonitor,Simatic Net Pc Software V14,Simatic Net Pc Software V16,Simatic Net Pc Software V17,Simatic Net Pc Software V18,Simatic Pcs 7 V9.1,Simatic Pcs Neo V4.0,Simatic S7-1500 Cpu 1510sp F-1 Pn,Simatic S7-1500 Cpu 1510sp-1 Pn,Simatic S7-1500 Cpu 1511-1 Pn,Simatic S7-1500 Cpu 1511c-1 Pn,Simatic S7-1500 Cpu 1511f-1 Pn,Simatic S7-1500 Cpu 1511t-1 Pn,Simatic S7-1500 Cpu 1511tf-1 Pn,Simatic S7-1500 Cpu 1512c-1 Pn,Simatic S7-1500 Cpu 1512sp F-1 Pn,Simatic S7-1500 Cpu 1512sp-1 Pn,Simatic S7-1500 Cpu 1513-1 Pn,Simatic S7-1500 Cpu 1513f-1 Pn,Simatic S7-1500 Cpu 1514sp F-2 Pn,Simatic S7-1500 Cpu 1514sp-2 Pn,Simatic S7-1500 Cpu 1514spt F-2 Pn,Simatic S7-1500 Cpu 1514spt-2 Pn,Simatic S7-1500 Cpu 1515-2 Pn,Simatic S7-1500 Cpu 1515f-2 Pn,Simatic S7-1500 Cpu 1515t-2 Pn,Simatic S7-1500 Cpu 1515tf-2 Pn,Simatic S7-1500 Cpu 1516-3 Pn/dp,Simatic S7-1500 Cpu 1516f-3 Pn/dp,Simatic S7-1500 Cpu 1516t-3 Pn/dp,Simatic S7-1500 Cpu 1516tf-3 Pn/dp,Simatic S7-1500 Cpu 1517-3 Pn/dp,Simatic S7-1500 Cpu 1517f-3 Pn/dp,Simatic S7-1500 Cpu 1517t-3 Pn/dp,Simatic S7-1500 Cpu 1517tf-3 Pn/dp,Simatic S7-1500 Cpu 1518-4 Pn/dp,Simatic S7-1500 Cpu 1518-4 Pn/dp Mfp,Simatic S7-1500 Cpu 1518f-4 Pn/dp,Simatic S7-1500 Cpu 1518f-4 Pn/dp Mfp,Simatic S7-1500 Cpu 1518t-4 Pn/dp,Simatic S7-1500 Cpu 1518tf-4 Pn/dp,Simatic S7-1500 Cpu S7-1518-4 Pn/dp Odk,Simatic S7-1500 Cpu S7-1518f-4 Pn/dp Odk,Simatic S7-1500 Et 200pro: Cpu 1513pro F-2 Pn,Simatic S7-1500 Et 200pro: Cpu 1513pro-2 Pn,Simatic S7-1500 Et 200pro: Cpu 1516pro F-2 Pn,Simatic S7-1500 Et 200pro: Cpu 1516pro-2 Pn,Simatic S7-1500 Software Controller V2,Simatic S7-1500 Software Controller V3,Simatic S7-plcsim Advanced,Simatic Sistar,Simatic Wincc Oa V3.17,Simatic Wincc Oa V3.18,Simatic Wincc Oa V3.19,Simatic Wincc Opc Ua Client,Simatic Wincc Runtime Professional V16,Simatic Wincc Runtime Professional V17,Simatic Wincc Runtime Professional V18,Simatic Wincc Runtime Professional V19,Simatic Wincc Unified Opc Ua Server,Simatic Wincc V7.4,Simatic Wincc V7.5,Simatic Wincc V8.0,Sinumerik Mc,Sinumerik One,Siplus Et 200sp Cpu 1510sp F-1 Pn,Siplus Et 200sp Cpu 1510sp F-1 Pn Rail,Siplus Et 200sp Cpu 1510sp-1 Pn,Siplus Et 200sp Cpu 1510sp-1 Pn Rail,Siplus Et 200sp Cpu 1512sp F-1 Pn,Siplus Et 200sp Cpu 1512sp F-1 Pn Rail,Siplus Et 200sp Cpu 1512sp-1 Pn,Siplus Et 200sp Cpu 1512sp-1 Pn Rail,Siplus S7-1500 Cpu 1511-1 Pn,Siplus S7-1500 Cpu 1511-1 Pn T1 Rail,Siplus S7-1500 Cpu 1511-1 Pn Tx Rail,Siplus S7-1500 Cpu 1511f-1 Pn,Siplus S7-1500 Cpu 1513-1 Pn,Siplus S7-1500 Cpu 1513f-1 Pn,Siplus S7-1500 Cpu 1515f-2 Pn,Siplus S7-1500 Cpu 1515f-2 Pn Rail,Siplus S7-1500 Cpu 1515f-2 Pn T2 Rail,Siplus S7-1500 Cpu 1516-3 Pn/dp,Siplus S7-1500 Cpu 1516-3 Pn/dp Rail,Siplus S7-1500 Cpu 1516-3 Pn/dp Tx Rail,Siplus S7-1500 Cpu 1516f-3 Pn/dp,Siplus S7-1500 Cpu 1516f-3 Pn/dp Rail,Siplus S7-1500 Cpu 1518-4 Pn/dp,Siplus S7-1500 Cpu 1518-4 Pn/dp Mfp,Siplus S7-1500 Cpu 1518f-4 Pn/dp",7.5,HIGH,0.0005300000193528831,false,,false,false,false,,false,false,2023-09-12T10:15:00.000Z,0 CVE-2023-28829,https://securityvulnerability.io/vulnerability/CVE-2023-28829,Vulnerability in SIMATIC NET and PCS 7 Software by Siemens,"A significant vulnerability exists in Siemens' SIMATIC NET PC Software and PCS 7 Software, affecting various versions of these products. The issue arises from the use of legacy OPC services (including OPC DA, OPC HDA, and OPC AE), which were default settings prior to the release of SIMATIC WinCC V8. These services rely on the outdated Windows ActiveX and DCOM technologies, lacking modern security measures for authentication and data encryption. This oversight leaves systems at risk of unauthorized access and potential data breaches.",Siemens,"SIMATIC NET PC Software V14,SIMATIC NET PC Software V15,SIMATIC PCS 7 V8.2,SIMATIC PCS 7 V9.0,SIMATIC PCS 7 V9.1,SIMATIC WinCC,SINAUT Software ST7sc",8.8,HIGH,0.0007099999929778278,false,,false,false,false,,false,false,2023-06-13T09:15:00.000Z,0 CVE-2023-25910,https://securityvulnerability.io/vulnerability/CVE-2023-25910,Database Management System Vulnerability in Siemens SIMATIC Products,"A vulnerability has been discovered in specific Siemens SIMATIC products that could potentially allow an attacker with network access to exploit embedded functions within the database management system. By leveraging these functions, users with low privileges may escalate their access, enabling them to execute code on the database server, thus posing significant security risks to infrastructure and data integrity.",Siemens,"Simatic Pcs 7,Simatic S7-pm,Simatic Step 7 V5",10,CRITICAL,0.0027000000700354576,false,,false,false,false,,false,false,2023-06-13T09:15:00.000Z,0 CVE-2022-24287,https://securityvulnerability.io/vulnerability/CVE-2022-24287,Vulnerability in Siemens SIMATIC Products Allows Kiosk Mode Escape,"A security flaw in Siemens' SIMATIC products allows an authenticated attacker to bypass the Kiosk Mode due to a missing printer configuration on the host. This vulnerability affects various versions of the SIMATIC PCS 7 and WinCC products, which could potentially lead to unauthorized access and manipulation of the systems. It is critical for users to ensure correct printer configurations to mitigate this risk effectively.",Siemens,"Simatic Pcs 7 V8.2,Simatic Pcs 7 V9.0,Simatic Pcs 7 V9.1,Simatic Wincc Runtime Professional V16 And Earlier,Simatic Wincc Runtime Professional V17,Simatic Wincc V7.3,Simatic Wincc V7.4,Simatic Wincc V7.5",7.8,HIGH,0.0004400000034365803,false,,false,false,false,,false,false,2022-05-20T13:15:00.000Z,0 CVE-2021-40363,https://securityvulnerability.io/vulnerability/CVE-2021-40363,,"A vulnerability has been identified in SIMATIC PCS 7 V8.2 (All versions), SIMATIC PCS 7 V9.0 (All versions), SIMATIC PCS 7 V9.1 (All versions < V9.1 SP1), SIMATIC WinCC V15 and earlier (All versions < V15 SP1 Update 7), SIMATIC WinCC V16 (All versions < V16 Update 5), SIMATIC WinCC V17 (All versions < V17 Update 2), SIMATIC WinCC V17 (All versions <= V17 Update 4), SIMATIC WinCC V7.4 (All versions < V7.4 SP1 Update 19), SIMATIC WinCC V7.5 (All versions < V7.5 SP2 Update 6). The affected component stores the credentials of a local system account in a potentially publicly accessible project file using an outdated cipher algorithm. An attacker may use this to brute force the credentials and take over the system.",Siemens,"Simatic Pcs 7 V8.2,Simatic Pcs 7 V9.0,Simatic Pcs 7 V9.1,Simatic Wincc V15 And Earlier,Simatic Wincc V16,Simatic Wincc V17,Simatic Wincc V7.4,Simatic Wincc V7.5",7.8,HIGH,0.0004400000034365803,false,,false,false,false,,false,false,2022-02-09T15:17:04.000Z,0 CVE-2021-40360,https://securityvulnerability.io/vulnerability/CVE-2021-40360,,"A vulnerability has been identified in SIMATIC PCS 7 V8.2 (All versions), SIMATIC PCS 7 V9.0 (All versions), SIMATIC PCS 7 V9.1 (All versions < V9.1 SP1), SIMATIC WinCC V15 and earlier (All versions < V15 SP1 Update 7), SIMATIC WinCC V16 (All versions < V16 Update 5), SIMATIC WinCC V17 (All versions < V17 Update 2), SIMATIC WinCC V7.4 (All versions < V7.4 SP1 Update 19), SIMATIC WinCC V7.5 (All versions < V7.5 SP2 Update 6). The password hash of a local user account in the remote server could be granted via public API to a user on the affected system. An authenticated attacker could brute force the password hash and use it to login to the server.",Siemens,"Simatic Pcs 7 V8.2,Simatic Pcs 7 V9.0,Simatic Pcs 7 V9.1,Simatic Wincc V15 And Earlier,Simatic Wincc V16,Simatic Wincc V17,Simatic Wincc V7.4,Simatic Wincc V7.5",8.8,HIGH,0.0008800000068731606,false,,false,false,false,,false,false,2022-02-09T15:17:03.000Z,0 CVE-2021-42022,https://securityvulnerability.io/vulnerability/CVE-2021-42022,,"A vulnerability has been identified in SIMATIC eaSie PCS 7 Skill Package (All versions < V21.00 SP3). When downloading files, the affected systems do not properly neutralize special elements within the pathname. An attacker could then cause the pathname to resolve to a location outside of the restricted directory on the server and read unexpected critical files. The affected file download function is disabled by default.",Siemens,Simatic Easie Pcs 7 Skill Package,6.5,MEDIUM,0.0009299999801442027,false,,false,false,false,,false,false,2021-12-14T12:06:37.000Z,0 CVE-2021-40364,https://securityvulnerability.io/vulnerability/CVE-2021-40364,,"A vulnerability has been identified in SIMATIC PCS 7 V8.2 (All versions), SIMATIC PCS 7 V9.0 (All versions < V9.0 SP3 UC04), SIMATIC PCS 7 V9.1 (All versions < V9.1 SP1), SIMATIC WinCC V15 and earlier (All versions < V15 SP1 Update 7), SIMATIC WinCC V16 (All versions < V16 Update 5), SIMATIC WinCC V17 (All versions < V17 Update 2), SIMATIC WinCC V7.4 (All versions < V7.4 SP1 Update 19), SIMATIC WinCC V7.5 (All versions < V7.5 SP2 Update 5). The affected systems store sensitive information in log files. An attacker with access to the log files could publicly expose the information or reuse it to develop further attacks on the system.",Siemens,"Simatic Pcs 7 V8.2,Simatic Pcs 7 V9.0,Simatic Pcs 7 V9.1,Simatic Wincc V15 And Earlier,Simatic Wincc V16,Simatic Wincc V17,Simatic Wincc V7.4,Simatic Wincc V7.5",5.5,MEDIUM,0.00139999995008111,false,,false,false,false,,false,false,2021-11-09T11:32:06.000Z,0 CVE-2021-40359,https://securityvulnerability.io/vulnerability/CVE-2021-40359,,"A vulnerability has been identified in OpenPCS 7 V8.2 (All versions), OpenPCS 7 V9.0 (All versions < V9.0 Upd4), OpenPCS 7 V9.1 (All versions), SIMATIC BATCH V8.2 (All versions), SIMATIC BATCH V9.0 (All versions), SIMATIC BATCH V9.1 (All versions), SIMATIC NET PC Software V14 (All versions), SIMATIC NET PC Software V15 (All versions), SIMATIC NET PC Software V16 (All versions < V16 Update 6), SIMATIC NET PC Software V17 (All versions < V17 SP1), SIMATIC PCS 7 V8.2 (All versions), SIMATIC PCS 7 V9.0 (All versions < V9.0 SP3 UC04), SIMATIC PCS 7 V9.1 (All versions < V9.1 SP1), SIMATIC Route Control V8.2 (All versions), SIMATIC Route Control V9.0 (All versions), SIMATIC Route Control V9.1 (All versions), SIMATIC WinCC V15 and earlier (All versions < V15 SP1 Update 7), SIMATIC WinCC V16 (All versions < V16 Update 5), SIMATIC WinCC V17 (All versions < V17 Update 2), SIMATIC WinCC V7.4 (All versions < V7.4 SP1 Update 19), SIMATIC WinCC V7.5 (All versions < V7.5 SP2 Update 5). When downloading files, the affected systems do not properly neutralize special elements within the pathname. An attacker could then cause the pathname to resolve to a location outside of the restricted directory on the server and read unexpected critical files.",Siemens,"Openpcs 7 V8.2,Openpcs 7 V9.0,Openpcs 7 V9.1,Simatic Batch V8.2,Simatic Batch V9.0,Simatic Batch V9.1,Simatic Net Pc Software V14,Simatic Net Pc Software V15,Simatic Net Pc Software V16,Simatic Net Pc Software V17,Simatic Pcs 7 V8.2,Simatic Pcs 7 V9.0,Simatic Pcs 7 V9.1,Simatic Route Control V8.2,Simatic Route Control V9.0,Simatic Route Control V9.1,Simatic Wincc V15 And Earlier,Simatic Wincc V16,Simatic Wincc V17,Simatic Wincc V7.4,Simatic Wincc V7.5",7.7,HIGH,0.0021299999207258224,false,,false,false,false,,false,false,2021-11-09T11:32:05.000Z,0 CVE-2021-40358,https://securityvulnerability.io/vulnerability/CVE-2021-40358,,"A vulnerability has been identified in SIMATIC PCS 7 V8.2 (All versions), SIMATIC PCS 7 V9.0 (All versions < V9.0 SP3 UC04), SIMATIC PCS 7 V9.1 (All versions < V9.1 SP1), SIMATIC WinCC V15 and earlier (All versions < V15 SP1 Update 7), SIMATIC WinCC V16 (All versions < V16 Update 5), SIMATIC WinCC V17 (All versions < V17 Update 2), SIMATIC WinCC V7.4 (All versions < V7.4 SP1 Update 19), SIMATIC WinCC V7.5 (All versions < V7.5 SP2 Update 5). Legitimate file operations on the web server of the affected systems do not properly neutralize special elements within the pathname. An attacker could then cause the pathname to resolve to a location outside of the restricted directory on the server and read, write or delete unexpected critical files.",Siemens,"Simatic Pcs 7 V8.2,Simatic Pcs 7 V9.0,Simatic Pcs 7 V9.1,Simatic Wincc V15 And Earlier,Simatic Wincc V16,Simatic Wincc V17,Simatic Wincc V7.4,Simatic Wincc V7.5",9.9,CRITICAL,0.002460000105202198,false,,false,false,false,,false,false,2021-11-09T11:32:04.000Z,0 CVE-2021-31894,https://securityvulnerability.io/vulnerability/CVE-2021-31894,,"A vulnerability has been identified in SIMATIC PCS 7 V8.2 and earlier (All versions), SIMATIC PCS 7 V9.X (All versions < V9.1 SP2), SIMATIC PDM (All versions < V9.2 SP2), SIMATIC STEP 7 V5.X (All versions < V5.7), SINAMICS STARTER (containing STEP 7 OEM version) (All versions < V5.4 SP2 HF1). A directory containing metafiles relevant to devices' configurations has write permissions. An attacker could leverage this vulnerability by changing the content of certain metafiles and subsequently manipulate parameters or behavior of devices that would be later configured by the affected software.",Siemens,"Simatic Pcs 7 V8.2 And Earlier,Simatic Pcs 7 V9.x,Simatic Pdm,Simatic Step 7 V5.x,Sinamics Starter (containing Step 7 Oem Version)",8.8,HIGH,0.0004400000034365803,false,,false,false,false,,false,false,2021-07-13T11:02:58.000Z,0 CVE-2021-31893,https://securityvulnerability.io/vulnerability/CVE-2021-31893,,"A vulnerability has been identified in SIMATIC PCS 7 V8.2 and earlier (All versions), SIMATIC PCS 7 V9.0 (All versions < V9.0 SP3), SIMATIC PDM (All versions < V9.2), SIMATIC STEP 7 V5.X (All versions < V5.6 SP2 HF3), SINAMICS STARTER (containing STEP 7 OEM version) (All versions < V5.4 HF2). The affected software contains a buffer overflow vulnerability while handling certain files that could allow a local attacker to trigger a denial-of-service condition or potentially lead to remote code execution.",Siemens,"Simatic Pcs 7 V8.2 And Earlier,Simatic Pcs 7 V9.0,Simatic Pdm,Simatic Step 7 V5.x,Sinamics Starter (containing Step 7 Oem Version)",7.8,HIGH,0.0017399999778717756,false,,false,false,false,,false,false,2021-07-13T11:02:56.000Z,0 CVE-2020-10048,https://securityvulnerability.io/vulnerability/CVE-2020-10048,,"A vulnerability has been identified in SIMATIC PCS 7 (All versions), SIMATIC WinCC (All versions < V7.5 SP2). Due to an insecure password verification process, an attacker could bypass the password protection set on protected files, thus being granted access to the protected content, circumventing authentication.",Siemens,"Simatic Pcs 7,Simatic Wincc",5.5,MEDIUM,0.0004400000034365803,false,,false,false,false,,false,false,2021-02-09T15:38:17.000Z,0 CVE-2020-7587,https://securityvulnerability.io/vulnerability/CVE-2020-7587,,"A vulnerability has been identified in Opcenter Execution Discrete (All versions < V3.2), Opcenter Execution Foundation (All versions < V3.2), Opcenter Execution Process (All versions < V3.2), Opcenter Intelligence (All versions < V3.3), Opcenter Quality (All versions < V11.3), Opcenter RD&L (V8.0), SIMATIC IT LMS (All versions < V2.6), SIMATIC IT Production Suite (All versions < V8.0), SIMATIC Notifier Server for Windows (All versions), SIMATIC PCS neo (All versions < V3.0 SP1), SIMATIC STEP 7 (TIA Portal) V15 (All versions < V15.1 Update 5), SIMATIC STEP 7 (TIA Portal) V16 (All versions < V16 Update 2), SIMOCODE ES V15.1 (All versions < V15.1 Update 4), SIMOCODE ES V16 (All versions < V16 Update 1), Soft Starter ES V15.1 (All versions < V15.1 Update 3), Soft Starter ES V16 (All versions < V16 Update 1). Sending multiple specially crafted packets to the affected service could cause a partial remote denial-of-service, that would cause the service to restart itself. On some cases the vulnerability could leak random information from the remote service.",Siemens,"Opcenter Execution Discrete,Opcenter Execution Foundation,Opcenter Execution Process,Opcenter Intelligence,Opcenter Quality,Opcenter Rd&l,Simatic It Lms,Simatic It Production Suite,Simatic Notifier Server For Windows,Simatic Pcs Neo,Simatic Step 7 (tia Portal) V15,Simatic Step 7 (tia Portal) V16,Simocode Es V15.1,Simocode Es V16,Soft Starter Es V15.1,Soft Starter Es V16",8.2,HIGH,0.002460000105202198,false,,false,false,false,,false,false,2020-07-14T13:18:05.000Z,0 CVE-2020-7581,https://securityvulnerability.io/vulnerability/CVE-2020-7581,,"A vulnerability has been identified in Opcenter Execution Discrete (All versions < V3.2), Opcenter Execution Foundation (All versions < V3.2), Opcenter Execution Process (All versions < V3.2), Opcenter Intelligence (All versions < V3.3), Opcenter Quality (All versions < V11.3), Opcenter RD&L (V8.0), SIMATIC Notifier Server for Windows (All versions), SIMATIC PCS neo (All versions < V3.0 SP1), SIMATIC STEP 7 (TIA Portal) V15 (All versions < V15.1 Update 5), SIMATIC STEP 7 (TIA Portal) V16 (All versions < V16 Update 2), SIMOCODE ES V15.1 (All versions < V15.1 Update 4), SIMOCODE ES V16 (All versions < V16 Update 1), Soft Starter ES V15.1 (All versions < V15.1 Update 3), Soft Starter ES V16 (All versions < V16 Update 1). A component within the affected application calls a helper binary with SYSTEM privileges during startup while the call path is not quoted. This could allow a local attacker with administrative privileges to execute code with SYSTEM level privileges.",Siemens,"Opcenter Execution Discrete,Opcenter Execution Foundation,Opcenter Execution Process,Opcenter Intelligence,Opcenter Quality,Opcenter Rd&l,Simatic Notifier Server For Windows,Simatic Pcs Neo,Simatic Step 7 (tia Portal) V15,Simatic Step 7 (tia Portal) V16,Simocode Es V15.1,Simocode Es V16,Soft Starter Es V15.1,Soft Starter Es V16",6.7,MEDIUM,0.0004199999966658652,false,,false,false,false,,false,false,2020-07-14T13:18:05.000Z,0 CVE-2020-7588,https://securityvulnerability.io/vulnerability/CVE-2020-7588,,"A vulnerability has been identified in Opcenter Execution Discrete (All versions < V3.2), Opcenter Execution Foundation (All versions < V3.2), Opcenter Execution Process (All versions < V3.2), Opcenter Intelligence (All versions < V3.3), Opcenter Quality (All versions < V11.3), Opcenter RD&L (V8.0), SIMATIC IT LMS (All versions < V2.6), SIMATIC IT Production Suite (All versions < V8.0), SIMATIC Notifier Server for Windows (All versions), SIMATIC PCS neo (All versions < V3.0 SP1), SIMATIC STEP 7 (TIA Portal) V15 (All versions < V15.1 Update 5), SIMATIC STEP 7 (TIA Portal) V16 (All versions < V16 Update 2), SIMOCODE ES V15.1 (All versions < V15.1 Update 4), SIMOCODE ES V16 (All versions < V16 Update 1), Soft Starter ES V15.1 (All versions < V15.1 Update 3), Soft Starter ES V16 (All versions < V16 Update 1). Sending a specially crafted packet to the affected service could cause a partial remote denial-of-service, that would cause the service to restart itself.",Siemens,"Opcenter Execution Discrete,Opcenter Execution Foundation,Opcenter Execution Process,Opcenter Intelligence,Opcenter Quality,Opcenter Rd&l,Simatic It Lms,Simatic It Production Suite,Simatic Notifier Server For Windows,Simatic Pcs Neo,Simatic Step 7 (tia Portal) V15,Simatic Step 7 (tia Portal) V16,Simocode Es V15.1,Simocode Es V16,Soft Starter Es V15.1,Soft Starter Es V16",5.3,MEDIUM,0.0010999999940395355,false,,false,false,false,,false,false,2020-07-14T13:18:05.000Z,0 CVE-2020-7586,https://securityvulnerability.io/vulnerability/CVE-2020-7586,,"A vulnerability has been identified in SIMATIC PCS 7 V8.2 and earlier (All versions), SIMATIC PCS 7 V9.0 (All versions < V9.0 SP3), SIMATIC PDM (All versions < V9.2), SIMATIC STEP 7 V5.X (All versions < V5.6 SP2 HF3), SINAMICS STARTER (containing STEP 7 OEM version) (All versions < V5.4 HF2). A buffer overflow vulnerability could allow a local attacker to cause a Denial-of-Service situation. The security vulnerability could be exploited by an attacker with local access to the affected systems. Successful exploitation requires user privileges but no user interaction. The vulnerability could allow an attacker to compromise the availability of the system as well as to have access to confidential information.",Siemens,"Simatic Pcs 7 V8.2 And Earlier,Simatic Pcs 7 V9.0,Simatic Pdm,Simatic Step 7 V5.x,Sinamics Starter (containing Step 7 Oem Version)",7.8,HIGH,0.0005200000014156103,false,,false,false,false,,false,false,2020-06-10T16:23:52.000Z,0 CVE-2020-7585,https://securityvulnerability.io/vulnerability/CVE-2020-7585,,"A vulnerability has been identified in SIMATIC PCS 7 V8.2 and earlier (All versions), SIMATIC PCS 7 V9.0 (All versions < V9.0 SP3), SIMATIC PDM (All versions < V9.2), SIMATIC STEP 7 V5.X (All versions < V5.6 SP2 HF3), SINAMICS STARTER (containing STEP 7 OEM version) (All versions < V5.4 HF2). A DLL Hijacking vulnerability could allow a local attacker to execute code with elevated privileges. The security vulnerability could be exploited by an attacker with local access to the affected systems. Successful exploitation requires user privileges but no user interaction. The vulnerability could allow an attacker to compromise the availability of the system as well as to have access to confidential information.",Siemens,"Simatic Pcs 7 V8.2 And Earlier,Simatic Pcs 7 V9.0,Simatic Pdm,Simatic Step 7 V5.x,Sinamics Starter (containing Step 7 Oem Version)",7.8,HIGH,0.0004199999966658652,false,,false,false,false,,false,false,2020-06-10T16:23:39.000Z,0