cve,link,title,description,vendor,products,score,severity,epss,cisa,cisa_published,article,ransomware,exploited,poc,trended,trended_no_1,published,trended_score CVE-2024-37995,https://securityvulnerability.io/vulnerability/CVE-2024-37995,SIMATIC Reader vulnerability could lead to sensitive information disclosure,"An identified vulnerability in Siemens' SIMATIC Reader devices, specifically in various RF610R, RF615R, RF650R, RF680R, RF685R, RF1140R, RF1170R, RF166C, RF185C, RF186C, RF186CI, RF188C, RF188CI, and RF360R models, allows improper handling of errors arising from faulty certificate uploads. This flaw can lead to crashes of the affected applications and potential exposure of sensitive information.",Siemens,"Simatic Reader Rf610r Cmiit,Simatic Reader Rf610r Etsi,Simatic Reader Rf610r Fcc,Simatic Reader Rf615r Cmiit,Simatic Reader Rf615r Etsi,Simatic Reader Rf615r Fcc,Simatic Reader Rf650r Arib,Simatic Reader Rf650r Cmiit,Simatic Reader Rf650r Etsi,Simatic Reader Rf650r Fcc,Simatic Reader Rf680r Arib,Simatic Reader Rf680r Cmiit,Simatic Reader Rf680r Etsi,Simatic Reader Rf680r Fcc,Simatic Reader Rf685r Arib,Simatic Reader Rf685r Cmiit,Simatic Reader Rf685r Etsi,Simatic Reader Rf685r Fcc,Simatic Rf1140r,Simatic Rf1170r,Simatic Rf166c,Simatic Rf185c,Simatic Rf186c,Simatic Rf186ci,Simatic Rf188c,Simatic Rf188ci,Simatic Rf360r",9.1,CRITICAL,0.0007399999885819852,false,,false,false,false,,false,false,2024-09-10T09:36:42.714Z,0 CVE-2024-37994,https://securityvulnerability.io/vulnerability/CVE-2024-37994,Hidden Configuration Item Could Lead to Deployment Insights,"A vulnerability has been detected in several SIMATIC Reader products, allowing potential attackers to exploit a hidden configuration item that enables debug functionality. This anomaly permits unauthorized access to the internal configuration settings of affected deployments. Specifically, it concerns all versions of the SIMATIC Reader RF610R, RF615R, RF650R, RF680R, RF685R, and others below the specified version thresholds. Organizations utilizing these products should take immediate action to address this security issue and protect their systems from potential exploitation.",Siemens,"Simatic Reader Rf610r Cmiit,Simatic Reader Rf610r Etsi,Simatic Reader Rf610r Fcc,Simatic Reader Rf615r Cmiit,Simatic Reader Rf615r Etsi,Simatic Reader Rf615r Fcc,Simatic Reader Rf650r Arib,Simatic Reader Rf650r Cmiit,Simatic Reader Rf650r Etsi,Simatic Reader Rf650r Fcc,Simatic Reader Rf680r Arib,Simatic Reader Rf680r Cmiit,Simatic Reader Rf680r Etsi,Simatic Reader Rf680r Fcc,Simatic Reader Rf685r Arib,Simatic Reader Rf685r Cmiit,Simatic Reader Rf685r Etsi,Simatic Reader Rf685r Fcc,Simatic Rf1140r,Simatic Rf1170r,Simatic Rf166c,Simatic Rf185c,Simatic Rf186c,Simatic Rf186ci,Simatic Rf188c,Simatic Rf188ci,Simatic Rf360r",7.1,HIGH,0.0004799999878741801,false,,false,false,false,,false,false,2024-09-10T09:36:40.841Z,0 CVE-2024-37993,https://securityvulnerability.io/vulnerability/CVE-2024-37993,Affected applications do not authenticate the creation of Ajax2App instances,"A vulnerability has been identified in several SIMATIC Reader products by Siemens, specifically in versions prior to V4.2. The flaw resides in the lack of authentication for the creation of Ajax2App instances. As a result, an unauthenticated attacker can exploit this vulnerability, potentially leading to a denial of service condition, thereby disrupting the normal operational capabilities of the affected devices.",Siemens,"Simatic Reader Rf610r Cmiit,Simatic Reader Rf610r Etsi,Simatic Reader Rf610r Fcc,Simatic Reader Rf615r Cmiit,Simatic Reader Rf615r Etsi,Simatic Reader Rf615r Fcc,Simatic Reader Rf650r Arib,Simatic Reader Rf650r Cmiit,Simatic Reader Rf650r Etsi,Simatic Reader Rf650r Fcc,Simatic Reader Rf680r Arib,Simatic Reader Rf680r Cmiit,Simatic Reader Rf680r Etsi,Simatic Reader Rf680r Fcc,Simatic Reader Rf685r Arib,Simatic Reader Rf685r Cmiit,Simatic Reader Rf685r Etsi,Simatic Reader Rf685r Fcc,Simatic Rf1140r,Simatic Rf1170r,Simatic Rf166c,Simatic Rf185c,Simatic Rf186c,Simatic Rf186ci,Simatic Rf188c,Simatic Rf188ci,Simatic Rf360r",7.5,HIGH,0.0004600000102072954,false,,false,false,false,,false,false,2024-09-10T09:36:39.074Z,0 CVE-2024-37992,https://securityvulnerability.io/vulnerability/CVE-2024-37992,SIMATIC Reader vulnerabilities due to error handling,"A vulnerability has been identified in various models of Siemens' SIMATIC Reader series, including models RF610R, RF615R, RF650R, RF680R, and RF685R, among others, specifically in versions prior to V4.2. This vulnerability arises from improper error handling when setting SNMP, particularly when character limits are exceeded. Such errors can result in unexpected application restarts, potentially impacting the performance and reliability of connected systems.",Siemens,"Simatic Reader Rf610r Cmiit,Simatic Reader Rf610r Etsi,Simatic Reader Rf610r Fcc,Simatic Reader Rf615r Cmiit,Simatic Reader Rf615r Etsi,Simatic Reader Rf615r Fcc,Simatic Reader Rf650r Arib,Simatic Reader Rf650r Cmiit,Simatic Reader Rf650r Etsi,Simatic Reader Rf650r Fcc,Simatic Reader Rf680r Arib,Simatic Reader Rf680r Cmiit,Simatic Reader Rf680r Etsi,Simatic Reader Rf680r Fcc,Simatic Reader Rf685r Arib,Simatic Reader Rf685r Cmiit,Simatic Reader Rf685r Etsi,Simatic Reader Rf685r Fcc,Simatic Rf1140r,Simatic Rf1170r,Simatic Rf166c,Simatic Rf185c,Simatic Rf186c,Simatic Rf186ci,Simatic Rf188c,Simatic Rf188ci,Simatic Rf360r",7.5,HIGH,0.0004600000102072954,false,,false,false,false,,false,false,2024-09-10T09:36:37.300Z,0 CVE-2024-37991,https://securityvulnerability.io/vulnerability/CVE-2024-37991,"Sensitive Information Accessible Without Authentication in SIMATIC Reader RF610R, RF615R, RF680R, and Other Products","A vulnerability has been identified in SIMATIC Reader RF610R CMIIT (6GT2811-6BC10-2AA0) (All versions < V4.2), SIMATIC Reader RF610R ETSI (6GT2811-6BC10-0AA0) (All versions < V4.2), SIMATIC Reader RF610R FCC (6GT2811-6BC10-1AA0) (All versions < V4.2), SIMATIC Reader RF615R CMIIT (6GT2811-6CC10-2AA0) (All versions < V4.2), SIMATIC Reader RF615R ETSI (6GT2811-6CC10-0AA0) (All versions < V4.2), SIMATIC Reader RF615R FCC (6GT2811-6CC10-1AA0) (All versions < V4.2), SIMATIC Reader RF650R ARIB (6GT2811-6AB20-4AA0) (All versions < V4.2), SIMATIC Reader RF650R CMIIT (6GT2811-6AB20-2AA0) (All versions < V4.2), SIMATIC Reader RF650R ETSI (6GT2811-6AB20-0AA0) (All versions < V4.2), SIMATIC Reader RF650R FCC (6GT2811-6AB20-1AA0) (All versions < V4.2), SIMATIC Reader RF680R ARIB (6GT2811-6AA10-4AA0) (All versions < V4.2), SIMATIC Reader RF680R CMIIT (6GT2811-6AA10-2AA0) (All versions < V4.2), SIMATIC Reader RF680R ETSI (6GT2811-6AA10-0AA0) (All versions < V4.2), SIMATIC Reader RF680R FCC (6GT2811-6AA10-1AA0) (All versions < V4.2), SIMATIC Reader RF685R ARIB (6GT2811-6CA10-4AA0) (All versions < V4.2), SIMATIC Reader RF685R CMIIT (6GT2811-6CA10-2AA0) (All versions < V4.2), SIMATIC Reader RF685R ETSI (6GT2811-6CA10-0AA0) (All versions < V4.2), SIMATIC Reader RF685R FCC (6GT2811-6CA10-1AA0) (All versions < V4.2), SIMATIC RF1140R (6GT2831-6CB00) (All versions < V1.1), SIMATIC RF1170R (6GT2831-6BB00) (All versions < V1.1), SIMATIC RF166C (6GT2002-0EE20) (All versions < V2.2), SIMATIC RF185C (6GT2002-0JE10) (All versions < V2.2), SIMATIC RF186C (6GT2002-0JE20) (All versions < V2.2), SIMATIC RF186CI (6GT2002-0JE50) (All versions < V2.2), SIMATIC RF188C (6GT2002-0JE40) (All versions < V2.2), SIMATIC RF188CI (6GT2002-0JE60) (All versions < V2.2), SIMATIC RF360R (6GT2801-5BA30) (All versions < V2.2). The service log files of the affected application can be accessed without proper authentication. This could allow an unauthenticated attacker to get access to sensitive information.",Siemens,"Simatic Reader Rf610r Cmiit,Simatic Reader Rf610r Etsi,Simatic Reader Rf610r Fcc,Simatic Reader Rf615r Cmiit,Simatic Reader Rf615r Etsi,Simatic Reader Rf615r Fcc,Simatic Reader Rf650r Arib,Simatic Reader Rf650r Cmiit,Simatic Reader Rf650r Etsi,Simatic Reader Rf650r Fcc,Simatic Reader Rf680r Arib,Simatic Reader Rf680r Cmiit,Simatic Reader Rf680r Etsi,Simatic Reader Rf680r Fcc,Simatic Reader Rf685r Arib,Simatic Reader Rf685r Cmiit,Simatic Reader Rf685r Etsi,Simatic Reader Rf685r Fcc,Simatic Rf1140r,Simatic Rf1170r,Simatic Rf166c,Simatic Rf185c,Simatic Rf186c,Simatic Rf186ci,Simatic Rf188c,Simatic Rf188ci,Simatic Rf360r",6.5,MEDIUM,0.0007399999885819852,false,,false,false,false,,false,false,2024-09-10T09:36:35.565Z,0 CVE-2024-37990,https://securityvulnerability.io/vulnerability/CVE-2024-37990,Vulnerability in SIMATIC Reader Products by Siemens,"A configuration file vulnerability exists in several SIMATIC Reader devices, allowing an attacker with privileged access to modify these files and potentially enable unauthorized features not meant for the device. This vulnerability affects multiple models across different geographical standards and necessitates urgent attention to secure device configurations.",Siemens,"Simatic Reader Rf610r Cmiit,Simatic Reader Rf610r Etsi,Simatic Reader Rf610r Fcc,Simatic Reader Rf615r Cmiit,Simatic Reader Rf615r Etsi,Simatic Reader Rf615r Fcc,Simatic Reader Rf650r Arib,Simatic Reader Rf650r Cmiit,Simatic Reader Rf650r Etsi,Simatic Reader Rf650r Fcc,Simatic Reader Rf680r Arib,Simatic Reader Rf680r Cmiit,Simatic Reader Rf680r Etsi,Simatic Reader Rf680r Fcc,Simatic Reader Rf685r Arib,Simatic Reader Rf685r Cmiit,Simatic Reader Rf685r Etsi,Simatic Reader Rf685r Fcc,Simatic Rf1140r,Simatic Rf1170r,Simatic Rf166c,Simatic Rf185c,Simatic Rf186c,Simatic Rf186ci,Simatic Rf188c,Simatic Rf188ci,Simatic Rf360r",6.5,MEDIUM,0.0004600000102072954,false,,false,false,false,,false,false,2024-09-10T09:36:33.772Z,0 CVE-2021-31340,https://securityvulnerability.io/vulnerability/CVE-2021-31340,,"A vulnerability has been identified in SIMATIC RF166C (All versions > V1.1 and < V1.3.2), SIMATIC RF185C (All versions > V1.1 and < V1.3.2), SIMATIC RF186C (All versions > V1.1 and < V1.3.2), SIMATIC RF186CI (All versions > V1.1 and < V1.3.2), SIMATIC RF188C (All versions > V1.1 and < V1.3.2), SIMATIC RF188CI (All versions > V1.1 and < V1.3.2), SIMATIC RF360R (All versions < V2.0), SIMATIC Reader RF610R CMIIT (All versions > V3.0 < V4.0), SIMATIC Reader RF610R ETSI (All versions > V3.0 < V4.0), SIMATIC Reader RF610R FCC (All versions > V3.0 < V4.0), SIMATIC Reader RF615R CMIIT (All versions > V3.0 < V4.0), SIMATIC Reader RF615R ETSI (All versions > V3.0 < V4.0), SIMATIC Reader RF615R FCC (All versions > V3.0 < V4.0), SIMATIC Reader RF650R ARIB (All versions > V3.0 < V4.0), SIMATIC Reader RF650R CMIIT (All versions > V3.0 < V4.0), SIMATIC Reader RF650R ETSI (All versions > V3.0 < V4.0), SIMATIC Reader RF650R FCC (All versions > V3.0 < V4.0), SIMATIC Reader RF680R ARIB (All versions > V3.0 < V4.0), SIMATIC Reader RF680R CMIIT (All versions > V3.0 < V4.0), SIMATIC Reader RF680R ETSI (All versions > V3.0 < V4.0), SIMATIC Reader RF680R FCC (All versions > V3.0 < V4.0), SIMATIC Reader RF685R ARIB (All versions > V3.0 < V4.0), SIMATIC Reader RF685R CMIIT (All versions > V3.0 < V4.0), SIMATIC Reader RF685R ETSI (All versions > V3.0 < V4.0), SIMATIC Reader RF685R FCC (All versions > V3.0 < V4.0). Affected devices do not properly handle large numbers of incoming connections. An attacker may leverage this to cause a Denial-of-Service situation.",Siemens,"Simatic Rf166c,Simatic Rf185c,Simatic Rf186c,Simatic Rf186ci,Simatic Rf188c,Simatic Rf188ci,Simatic Rf360r,Simatic Reader Rf610r Cmiit,Simatic Reader Rf610r Etsi,Simatic Reader Rf610r Fcc,Simatic Reader Rf615r Cmiit,Simatic Reader Rf615r Etsi,Simatic Reader Rf615r Fcc,Simatic Reader Rf650r Arib,Simatic Reader Rf650r Cmiit,Simatic Reader Rf650r Etsi,Simatic Reader Rf650r Fcc,Simatic Reader Rf680r Arib,Simatic Reader Rf680r Cmiit,Simatic Reader Rf680r Etsi,Simatic Reader Rf680r Fcc,Simatic Reader Rf685r Arib,Simatic Reader Rf685r Cmiit,Simatic Reader Rf685r Etsi,Simatic Reader Rf685r Fcc",7.5,HIGH,0.0010300000431016088,false,,false,false,false,,false,false,2021-06-08T19:47:16.000Z,0 CVE-2017-2681,https://securityvulnerability.io/vulnerability/CVE-2017-2681,,Specially crafted PROFINET DCP packets sent on a local Ethernet segment (Layer 2) to an affected product could cause a denial of service condition of that product. Human interaction is required to recover the system. PROFIBUS interfaces are not affected.,Siemens,"Development/evaluation Kits For Profinet Io: Dk Standard Ethernet Controller,Development/evaluation Kits For Profinet Io: Ek-ertec 200,Development/evaluation Kits For Profinet Io: Ek-ertec 200p,Ie/as-i Link Pn Io,Ie/pb-link (incl. Siplus Net Variants),Scalance M-800 Family (incl. S615, Mum-800 And Rm1224),Scalance W-700 Ieee 802.11n Family,Scalance X-200 Family (incl. Siplus Net Variants),Scalance X-200irt Family (incl. Siplus Net Variants),Scalance X-300 Family (incl. X408 And Siplus Net Variants),Scalance X408 Family,Scalance X414,Scalance Xm-400 Family,Scalance Xr-500 Family,Simatic Cm 1542-1,Simatic Cm 1542sp-1,Simatic Cp 1243-1 (incl. Siplus Variants),Simatic Cp 1243-1 Dnp3 (incl. Siplus Variants),Simatic Cp 1243-1 Iec (incl. Siplus Variants),Simatic Cp 1243-8 Irc,Simatic Cp 1542sp-1 Irc (incl. Siplus Variants),Simatic Cp 1543-1 (incl. Siplus Variants),Simatic Cp 1543sp-1 (incl. Siplus Variants),Simatic Cp 1604,Simatic Cp 1616,Simatic Cp 343-1 (incl. Siplus Variants),Simatic Cp 343-1 Advanced (incl. Siplus Variants),Simatic Cp 343-1 Lean (incl. Siplus Variants),Simatic Cp 443-1 (incl. Siplus Variants),Simatic Cp 443-1 Advanced (incl. Siplus Variants),Simatic Cp 443-1 Opc Ua,Simatic Dk-16xx Pn Io,Simatic Et 200al Im 157-1 Pn,Simatic Et 200m (incl. Siplus Variants),Simatic Et 200mp Im 155-5 Pn Ba,Simatic Et 200mp Im 155-5 Pn Hf,Simatic Et 200mp Im 155-5 Pn St,Simatic Et 200pro Im 154-3 Pn Hf,Simatic Et 200pro Im 154-4 Pn Hf,Simatic Et 200sp Im 155-6 Pn Ba,Simatic Et 200sp Im 155-6 Pn Hf,Simatic Et 200sp Im 155-6 Pn Hs,Simatic Et 200sp Im 155-6 Pn St,Simatic Et 200sp Im 155-6 Pn St Ba,Simatic Et200ecopn, 16di, Dc24v, 8xm12,Simatic Et200ecopn, 16do Dc24v/1,3a, 8xm12,Simatic Et200ecopn, 4ao U/i 4xm12,Simatic Et200ecopn, 8 Dio, Dc24v/1,3a, 8xm12,Simatic Et200ecopn, 8 Do, Dc24v/2a, 8xm12,Simatic Et200ecopn, 8ai Rtd/tc 8xm12,Simatic Et200ecopn, 8ai; 4 U/i; 4 Rtd/tc 8xm12,Simatic Et200ecopn, 8di, Dc24v, 4xm12,Simatic Et200ecopn, 8di, Dc24v, 8xm12,Simatic Et200ecopn, 8do, Dc24v/0,5a, 4xm12,Simatic Et200ecopn, 8do, Dc24v/1,3a, 4xm12,Simatic Et200ecopn, 8do, Dc24v/1,3a, 8xm12,Simatic Et200ecopn: Io-link Master,Simatic Et200s (incl. Siplus Variants),Simatic Hmi Comfort Panels, Hmi Multi Panels, Hmi Mobile Panels (incl. Siplus Variants),Simatic Mv420 Sr-b,Simatic Mv420 Sr-b Body,Simatic Mv420 Sr-p,Simatic Mv420 Sr-p Body,Simatic Mv440 Hr,Simatic Mv440 Sr,Simatic Mv440 Ur,Simatic Pn/pn Coupler (incl. Siplus Net Variants),Simatic Rf650r,Simatic Rf680r,Simatic Rf685r,Simatic S7-1200 Cpu Family (incl. Siplus Variants),Simatic S7-1500 Cpu Family (incl. Related Et200 Cpus And Siplus Variants),Simatic S7-1500 Software Controller,Simatic S7-200 Smart,Simatic S7-300 Cpu Family (incl. Related Et200 Cpus And Siplus Variants),Simatic S7-400 H V6 Cpu Family (incl. Siplus Variants),Simatic S7-400 Pn/dp V6 Cpu Family (incl. Siplus Variants),Simatic S7-400 Pn/dp V7 Cpu Family (incl. Siplus Variants),Simatic S7-410 Cpu Family (incl. Siplus Variants),Simatic Tdc Cp51m1,Simatic Tdc Cpu555,Simatic Teleservice Adapter Ie Advanced,Simatic Teleservice Adapter Ie Basic,Simatic Teleservice Adapter Ie Standard,Simatic Winac Rtx 2010,Simatic Winac Rtx F 2010,Simocode Pro V Profinet (incl. Siplus Variants),Simotion,Sinamics Dcm W. Pn,Sinamics Dcp W. Pn,Sinamics G110m W. Pn,Sinamics G120(c/p/d) W. Pn (incl. Siplus Variants),Sinamics G130 V4.7 W. Pn,Sinamics G130 V4.8 W. Pn,Sinamics G150 V4.7 W. Pn,Sinamics G150 V4.8 W. Pn,Sinamics S110 W. Pn,Sinamics S120 Prior To V4.7 W. Pn (incl. Siplus Variants),Sinamics S120 V4.7 Sp1 W. Pn (incl. Siplus Variants),Sinamics S120 V4.7 W. Pn (incl. Siplus Variants),Sinamics S120 V4.8 W. Pn (incl. Siplus Variants),Sinamics S150 V4.7 W. Pn,Sinamics S150 V4.8 W. Pn,Sinamics V90 W. Pn,Sinumerik 828d V4.5 And Prior,Sinumerik 828d V4.7,Sinumerik 840d Sl V4.5 And Prior,Sinumerik 840d Sl V4.7,Siplus Et 200mp Im 155-5 Pn Hf,Siplus Et 200mp Im 155-5 Pn Hf T1 Rail,Siplus Et 200mp Im 155-5 Pn St,Siplus Et 200mp Im 155-5 Pn St Tx Rail,Siplus Et 200sp Im 155-6 Pn Hf,Siplus Et 200sp Im 155-6 Pn Hf T1 Rail,Siplus Et 200sp Im 155-6 Pn St,Siplus Et 200sp Im 155-6 Pn St Ba,Siplus Et 200sp Im 155-6 Pn St Ba Tx Rail,Siplus Et 200sp Im 155-6 Pn St Tx Rail,Sirius Act 3su1 Interface Module Profinet,Sirius Motor Starter M200d Profinet,Sirius Soft Starter 3rw44 Pn,Sitop Psu8600 Profinet,Sitop Ups1600 Profinet (incl. Siplus Variants),Softnet Profinet Io For Pc-based Windows Systems",6.5,MEDIUM,0.0019399999873712659,false,,false,false,false,,false,false,2017-05-11T10:00:00.000Z,0 CVE-2017-2680,https://securityvulnerability.io/vulnerability/CVE-2017-2680,,Specially crafted PROFINET DCP broadcast packets could cause a denial of service condition of affected products on a local Ethernet segment (Layer 2). Human interaction is required to recover the systems. PROFIBUS interfaces are not affected.,Siemens,"Development/evaluation Kits For Profinet Io: Dk Standard Ethernet Controller,Development/evaluation Kits For Profinet Io: Ek-ertec 200,Development/evaluation Kits For Profinet Io: Ek-ertec 200p,Extension Unit 12"" Profinet,Extension Unit 15"" Profinet,Extension Unit 19"" Profinet,Extension Unit 22"" Profinet,Ie/as-i Link Pn Io,Ie/pb-link (incl. Siplus Net Variants),Scalance M-800 Family (incl. S615, Mum-800 And Rm1224),Scalance W-700 Ieee 802.11n Family,Scalance X-200 Family (incl. Siplus Net Variants),Scalance X-200irt Family (incl. Siplus Net Variants),Scalance X-300 Family (incl. X408 And Siplus Net Variants),Scalance X408 Family,Scalance X414,Scalance Xm-400 Family,Scalance Xr-500 Family,Simatic Cm 1542-1,Simatic Cm 1542sp-1,Simatic Cp 1242-7 V2 (incl. Siplus Variants),Simatic Cp 1243-1 (incl. Siplus Variants),Simatic Cp 1243-1 Dnp3 (incl. Siplus Variants),Simatic Cp 1243-1 Iec (incl. Siplus Variants),Simatic Cp 1243-7 Lte Us,Simatic Cp 1243-8 Irc,Simatic Cp 1542sp-1 Irc (incl. Siplus Variants),Simatic Cp 1543-1 (incl. Siplus Variants),Simatic Cp 1543sp-1 (incl. Siplus Variants),Simatic Cp 1604,Simatic Cp 1616,Simatic Cp 1626,Simatic Cp 343-1 (incl. Siplus Variants),Simatic Cp 343-1 Advanced (incl. Siplus Variants),Simatic Cp 343-1 Lean (incl. Siplus Variants),Simatic Cp 443-1 (incl. Siplus Variants),Simatic Cp 443-1 Advanced (incl. Siplus Variants),Simatic Cp 443-1 Opc Ua,Simatic Dk-16xx Pn Io,Simatic Et 200al Im 157-1 Pn,Simatic Et 200m (incl. Siplus Variants),Simatic Et 200mp Im 155-5 Pn Ba,Simatic Et 200mp Im 155-5 Pn Hf,Simatic Et 200mp Im 155-5 Pn St,Simatic Et 200pro Im 154-3 Pn Hf,Simatic Et 200pro Im 154-4 Pn Hf,Simatic Et 200sp Im 155-6 Pn Ba,Simatic Et 200sp Im 155-6 Pn Hf,Simatic Et 200sp Im 155-6 Pn Hs,Simatic Et 200sp Im 155-6 Pn St,Simatic Et 200sp Im 155-6 Pn St Ba,Simatic Et200ecopn, 16di, Dc24v, 8xm12,Simatic Et200ecopn, 16do Dc24v/1,3a, 8xm12,Simatic Et200ecopn, 4ao U/i 4xm12,Simatic Et200ecopn, 8 Dio, Dc24v/1,3a, 8xm12,Simatic Et200ecopn, 8 Do, Dc24v/2a, 8xm12,Simatic Et200ecopn, 8ai Rtd/tc 8xm12,Simatic Et200ecopn, 8ai; 4 U/i; 4 Rtd/tc 8xm12,Simatic Et200ecopn, 8di, Dc24v, 4xm12,Simatic Et200ecopn, 8di, Dc24v, 8xm12,Simatic Et200ecopn, 8do, Dc24v/0,5a, 4xm12,Simatic Et200ecopn, 8do, Dc24v/1,3a, 4xm12,Simatic Et200ecopn, 8do, Dc24v/1,3a, 8xm12,Simatic Et200ecopn: Io-link Master,Simatic Et200s (incl. Siplus Variants),Simatic Hmi Comfort Panels, Hmi Multi Panels, Hmi Mobile Panels (incl. Siplus Variants),Simatic Mv420 Sr-b,Simatic Mv420 Sr-b Body,Simatic Mv420 Sr-p,Simatic Mv420 Sr-p Body,Simatic Mv440 Hr,Simatic Mv440 Sr,Simatic Mv440 Ur,Simatic Pn/pn Coupler (incl. Siplus Net Variants),Simatic Rf650r,Simatic Rf680r,Simatic Rf685r,Simatic S7-1200 Cpu Family (incl. Siplus Variants),Simatic S7-1500 Cpu Family (incl. Related Et200 Cpus And Siplus Variants),Simatic S7-1500 Software Controller,Simatic S7-200 Smart,Simatic S7-300 Cpu Family (incl. Related Et200 Cpus And Siplus Variants),Simatic S7-400 H V6 Cpu Family (incl. Siplus Variants),Simatic S7-400 Pn/dp V6 Cpu Family (incl. Siplus Variants),Simatic S7-400 Pn/dp V7 Cpu Family (incl. Siplus Variants),Simatic S7-410 Cpu Family (incl. Siplus Variants),Simatic Tdc Cp51m1,Simatic Tdc Cpu555,Simatic Teleservice Adapter Ie Advanced,Simatic Teleservice Adapter Ie Basic,Simatic Teleservice Adapter Ie Standard,Simatic Winac Rtx 2010,Simatic Winac Rtx F 2010,Simocode Pro V Profinet (incl. Siplus Variants),Simotion,Simotion D4xx V4.4 For Sinamics Sm150i-2 W. Profinet (incl. Siplus Variants),Sinamics Dcm W. Pn,Sinamics Dcp W. Pn,Sinamics G110m W. Pn,Sinamics G120(c/p/d) W. Pn (incl. Siplus Variants),Sinamics G130 V4.7 W. Pn,Sinamics G130 V4.8 W. Pn,Sinamics G150 V4.7 W. Pn,Sinamics G150 V4.8 W. Pn,Sinamics Gh150 V4.7 W. Profinet,Sinamics Gl150 V4.7 W. Profinet,Sinamics Gm150 V4.7 W. Profinet,Sinamics S110 W. Pn,Sinamics S120 Prior To V4.7 W. Pn (incl. Siplus Variants),Sinamics S120 V4.7 Sp1 W. Pn (incl. Siplus Variants),Sinamics S120 V4.7 W. Pn (incl. Siplus Variants),Sinamics S120 V4.8 W. Pn (incl. Siplus Variants),Sinamics S150 V4.7 W. Pn,Sinamics S150 V4.8 W. Pn,Sinamics Sl150 V4.7.0 W. Profinet,Sinamics Sl150 V4.7.4 W. Profinet,Sinamics Sl150 V4.7.5 W. Profinet,Sinamics Sm120 V4.7 W. Profinet,Sinamics V90 W. Pn,Sinumerik 828d V4.5 And Prior,Sinumerik 828d V4.7,Sinumerik 840d Sl V4.5 And Prior,Sinumerik 840d Sl V4.7,Siplus Et 200mp Im 155-5 Pn Hf,Siplus Et 200mp Im 155-5 Pn Hf T1 Rail,Siplus Et 200mp Im 155-5 Pn St,Siplus Et 200mp Im 155-5 Pn St Tx Rail,Siplus Et 200sp Im 155-6 Pn Hf,Siplus Et 200sp Im 155-6 Pn Hf T1 Rail,Siplus Et 200sp Im 155-6 Pn St,Siplus Et 200sp Im 155-6 Pn St Ba,Siplus Et 200sp Im 155-6 Pn St Ba Tx Rail,Siplus Et 200sp Im 155-6 Pn St Tx Rail,Sirius Act 3su1 Interface Module Profinet,Sirius Motor Starter M200d Profinet,Sirius Soft Starter 3rw44 Pn,Sitop Psu8600 Profinet,Sitop Ups1600 Profinet (incl. Siplus Variants),Softnet Profinet Io For Pc-based Windows Systems",6.5,MEDIUM,0.0024999999441206455,false,,false,false,false,,false,false,2017-05-11T01:00:00.000Z,0