cve,link,title,description,vendor,products,score,severity,epss,cisa,cisa_published,article,ransomware,exploited,poc,trended,trended_no_1,published,trended_score CVE-2021-31894,https://securityvulnerability.io/vulnerability/CVE-2021-31894,,"A vulnerability has been identified in SIMATIC PCS 7 V8.2 and earlier (All versions), SIMATIC PCS 7 V9.X (All versions < V9.1 SP2), SIMATIC PDM (All versions < V9.2 SP2), SIMATIC STEP 7 V5.X (All versions < V5.7), SINAMICS STARTER (containing STEP 7 OEM version) (All versions < V5.4 SP2 HF1). A directory containing metafiles relevant to devices' configurations has write permissions. An attacker could leverage this vulnerability by changing the content of certain metafiles and subsequently manipulate parameters or behavior of devices that would be later configured by the affected software.",Siemens,"Simatic Pcs 7 V8.2 And Earlier,Simatic Pcs 7 V9.x,Simatic Pdm,Simatic Step 7 V5.x,Sinamics Starter (containing Step 7 Oem Version)",8.8,HIGH,0.0004400000034365803,false,,false,false,false,,false,false,2021-07-13T11:02:58.000Z,0 CVE-2021-31893,https://securityvulnerability.io/vulnerability/CVE-2021-31893,,"A vulnerability has been identified in SIMATIC PCS 7 V8.2 and earlier (All versions), SIMATIC PCS 7 V9.0 (All versions < V9.0 SP3), SIMATIC PDM (All versions < V9.2), SIMATIC STEP 7 V5.X (All versions < V5.6 SP2 HF3), SINAMICS STARTER (containing STEP 7 OEM version) (All versions < V5.4 HF2). The affected software contains a buffer overflow vulnerability while handling certain files that could allow a local attacker to trigger a denial-of-service condition or potentially lead to remote code execution.",Siemens,"Simatic Pcs 7 V8.2 And Earlier,Simatic Pcs 7 V9.0,Simatic Pdm,Simatic Step 7 V5.x,Sinamics Starter (containing Step 7 Oem Version)",7.8,HIGH,0.0017399999778717756,false,,false,false,false,,false,false,2021-07-13T11:02:56.000Z,0 CVE-2020-7586,https://securityvulnerability.io/vulnerability/CVE-2020-7586,,"A vulnerability has been identified in SIMATIC PCS 7 V8.2 and earlier (All versions), SIMATIC PCS 7 V9.0 (All versions < V9.0 SP3), SIMATIC PDM (All versions < V9.2), SIMATIC STEP 7 V5.X (All versions < V5.6 SP2 HF3), SINAMICS STARTER (containing STEP 7 OEM version) (All versions < V5.4 HF2). A buffer overflow vulnerability could allow a local attacker to cause a Denial-of-Service situation. The security vulnerability could be exploited by an attacker with local access to the affected systems. Successful exploitation requires user privileges but no user interaction. The vulnerability could allow an attacker to compromise the availability of the system as well as to have access to confidential information.",Siemens,"Simatic Pcs 7 V8.2 And Earlier,Simatic Pcs 7 V9.0,Simatic Pdm,Simatic Step 7 V5.x,Sinamics Starter (containing Step 7 Oem Version)",7.8,HIGH,0.0005200000014156103,false,,false,false,false,,false,false,2020-06-10T16:23:52.000Z,0 CVE-2020-7585,https://securityvulnerability.io/vulnerability/CVE-2020-7585,,"A vulnerability has been identified in SIMATIC PCS 7 V8.2 and earlier (All versions), SIMATIC PCS 7 V9.0 (All versions < V9.0 SP3), SIMATIC PDM (All versions < V9.2), SIMATIC STEP 7 V5.X (All versions < V5.6 SP2 HF3), SINAMICS STARTER (containing STEP 7 OEM version) (All versions < V5.4 HF2). A DLL Hijacking vulnerability could allow a local attacker to execute code with elevated privileges. The security vulnerability could be exploited by an attacker with local access to the affected systems. Successful exploitation requires user privileges but no user interaction. The vulnerability could allow an attacker to compromise the availability of the system as well as to have access to confidential information.",Siemens,"Simatic Pcs 7 V8.2 And Earlier,Simatic Pcs 7 V9.0,Simatic Pdm,Simatic Step 7 V5.x,Sinamics Starter (containing Step 7 Oem Version)",7.8,HIGH,0.0004199999966658652,false,,false,false,false,,false,false,2020-06-10T16:23:39.000Z,0 CVE-2017-6865,https://securityvulnerability.io/vulnerability/CVE-2017-6865,,"A vulnerability has been identified in Primary Setup Tool (PST) (All versions < V4.2 HF1), SIMATIC Automation Tool (All versions < V3.0), SIMATIC NET PC-Software (All versions < V14 SP1), SIMATIC PCS 7 V8.1 (All versions), SIMATIC PCS 7 V8.2 (All versions < V8.2 SP1), SIMATIC STEP 7 (TIA Portal) V13 (All versions < V13 SP2), SIMATIC STEP 7 (TIA Portal) V14 (All versions < V14 SP1), SIMATIC STEP 7 V5.X (All versions < V5.6), SIMATIC WinAC RTX 2010 SP2 (All versions), SIMATIC WinAC RTX F 2010 SP2 (All versions), SIMATIC WinCC (TIA Portal) V13 (All versions < V13 SP2), SIMATIC WinCC (TIA Portal) V14 (All versions < V14 SP1), SIMATIC WinCC V7.2 and prior (All versions), SIMATIC WinCC V7.3 (All versions < V7.3 Update 15), SIMATIC WinCC V7.4 (All versions < V7.4 SP1 Upd1), SIMATIC WinCC flexible 2008 (All versions < flexible 2008 SP5), SINAUT ST7CC (All versions installed in conjunction with SIMATIC WinCC < V7.3 Update 15), SINEMA Server (All versions < V14), SINUMERIK 808D Programming Tool (All versions < V4.7 SP4 HF2), SMART PC Access (All versions < V2.3), STEP 7 - Micro/WIN SMART (All versions < V2.3), Security Configuration Tool (SCT) (All versions < V5.0). Specially crafted PROFINET DCP broadcast packets sent to the affected products on a local Ethernet segment (Layer 2) could cause a Denial-of-Service condition of some services. The services require manual restart to recover.",Siemens,"Primary Setup Tool (pst),Simatic Automation Tool,Simatic Net Pc-software,Simatic Pcs 7 V8.1,Simatic Pcs 7 V8.2,Simatic Step 7 (tia Portal) V13,Simatic Step 7 (tia Portal) V14,Simatic Step 7 V5.x,Simatic Winac Rtx 2010 Sp2,Simatic Winac Rtx F 2010 Sp2,Simatic Wincc (tia Portal) V13,Simatic Wincc (tia Portal) V14,Simatic Wincc V7.2 And Prior,Simatic Wincc V7.3,Simatic Wincc V7.4,Simatic Wincc Flexible 2008,Sinaut St7cc,Sinema Server,Sinumerik 808d Programming Tool,Smart Pc Access,Step 7 - Micro/win Smart,Security Configuration Tool (sct)",6.5,MEDIUM,0.0006799999973736703,false,,false,false,false,,false,false,2017-05-11T10:00:00.000Z,0