cve,link,title,description,vendor,products,score,severity,epss,cisa,cisa_published,article,ransomware,exploited,poc,trended,trended_no_1,published,trended_score CVE-2023-46280,https://securityvulnerability.io/vulnerability/CVE-2023-46280,Out of Bounds Read Vulnerability in SIMATIC and TIA Portal Products by Siemens,"An out of bounds read vulnerability has been identified in multiple Siemens products, including the SIMATIC and TIA Portal series. This flaw can potentially lead to the crashing of the Windows kernel, resulting in a Blue Screen of Death (BSOD) error. Attackers could exploit this vulnerability to destabilize systems, impacting operational efficiency and safety within industrial environments. It is crucial for users of these products to be aware of this vulnerability and to implement necessary mitigations as outlined by Siemens.",Siemens,"Security Configuration Tool (sct),Simatic Automation Tool,Simatic Batch V9.1,Simatic Net Pc Software V16,Simatic Net Pc Software V17,Simatic Net Pc Software V18,Simatic Net Pc Software V19,Simatic Pcs 7 V9.1,Simatic Pdm V9.2,Simatic Route Control V9.1,Simatic S7-pct,Simatic Step 7 V5,Simatic Wincc Oa V3.17,Simatic Wincc Oa V3.18,Simatic Wincc Oa V3.19,Simatic Wincc Runtime Advanced,Simatic Wincc Runtime Professional V16,Simatic Wincc Runtime Professional V17,Simatic Wincc Runtime Professional V18,Simatic Wincc Runtime Professional V19,Simatic Wincc V7.4,Simatic Wincc V7.5,Simatic Wincc V8.0,Sinamics Startdrive,Sinec Nms,Sinumerik One Virtual,Sinumerik Plc Programming Tool,Tia Portal Cloud Connector,Totally Integrated Automation Portal (tia Portal) V15.1,Totally Integrated Automation Portal (tia Portal) V16,Totally Integrated Automation Portal (tia Portal) V17,Totally Integrated Automation Portal (tia Portal) V18,Totally Integrated Automation Portal (tia Portal) V19",6.5,MEDIUM,0.00044999999227002263,false,,false,false,false,,false,false,2024-05-14T10:01:52.069Z,0 CVE-2023-28831,https://securityvulnerability.io/vulnerability/CVE-2023-28831,Integer Overflow Issue in Siemens OPC UA Implementations,"The OPC UA implementations in Siemens products harbor an integer overflow vulnerability that can lead to an infinite loop during the certificate validation process. This condition could be exploited by an unauthenticated remote attacker utilizing a specially crafted certificate, resulting in a denial of service that impacts application availability and reliability.",Siemens,"Simatic Braumat,Simatic Cloud Connect 7 Cc712,Simatic Cloud Connect 7 Cc716,Simatic Comfort/mobile Rt,Simatic Drive Controller Cpu 1504d Tf,Simatic Drive Controller Cpu 1507d Tf,Simatic Et 200sp Open Controller Cpu 1515sp Pc2 (incl. Siplus Variants),Simatic Ipc Diagmonitor,Simatic Net Pc Software V14,Simatic Net Pc Software V16,Simatic Net Pc Software V17,Simatic Net Pc Software V18,Simatic Pcs 7 V9.1,Simatic Pcs Neo V4.0,Simatic S7-1500 Cpu 1510sp F-1 Pn,Simatic S7-1500 Cpu 1510sp-1 Pn,Simatic S7-1500 Cpu 1511-1 Pn,Simatic S7-1500 Cpu 1511c-1 Pn,Simatic S7-1500 Cpu 1511f-1 Pn,Simatic S7-1500 Cpu 1511t-1 Pn,Simatic S7-1500 Cpu 1511tf-1 Pn,Simatic S7-1500 Cpu 1512c-1 Pn,Simatic S7-1500 Cpu 1512sp F-1 Pn,Simatic S7-1500 Cpu 1512sp-1 Pn,Simatic S7-1500 Cpu 1513-1 Pn,Simatic S7-1500 Cpu 1513f-1 Pn,Simatic S7-1500 Cpu 1514sp F-2 Pn,Simatic S7-1500 Cpu 1514sp-2 Pn,Simatic S7-1500 Cpu 1514spt F-2 Pn,Simatic S7-1500 Cpu 1514spt-2 Pn,Simatic S7-1500 Cpu 1515-2 Pn,Simatic S7-1500 Cpu 1515f-2 Pn,Simatic S7-1500 Cpu 1515t-2 Pn,Simatic S7-1500 Cpu 1515tf-2 Pn,Simatic S7-1500 Cpu 1516-3 Pn/dp,Simatic S7-1500 Cpu 1516f-3 Pn/dp,Simatic S7-1500 Cpu 1516t-3 Pn/dp,Simatic S7-1500 Cpu 1516tf-3 Pn/dp,Simatic S7-1500 Cpu 1517-3 Pn/dp,Simatic S7-1500 Cpu 1517f-3 Pn/dp,Simatic S7-1500 Cpu 1517t-3 Pn/dp,Simatic S7-1500 Cpu 1517tf-3 Pn/dp,Simatic S7-1500 Cpu 1518-4 Pn/dp,Simatic S7-1500 Cpu 1518-4 Pn/dp Mfp,Simatic S7-1500 Cpu 1518f-4 Pn/dp,Simatic S7-1500 Cpu 1518f-4 Pn/dp Mfp,Simatic S7-1500 Cpu 1518t-4 Pn/dp,Simatic S7-1500 Cpu 1518tf-4 Pn/dp,Simatic S7-1500 Cpu S7-1518-4 Pn/dp Odk,Simatic S7-1500 Cpu S7-1518f-4 Pn/dp Odk,Simatic S7-1500 Et 200pro: Cpu 1513pro F-2 Pn,Simatic S7-1500 Et 200pro: Cpu 1513pro-2 Pn,Simatic S7-1500 Et 200pro: Cpu 1516pro F-2 Pn,Simatic S7-1500 Et 200pro: Cpu 1516pro-2 Pn,Simatic S7-1500 Software Controller V2,Simatic S7-1500 Software Controller V3,Simatic S7-plcsim Advanced,Simatic Sistar,Simatic Wincc Oa V3.17,Simatic Wincc Oa V3.18,Simatic Wincc Oa V3.19,Simatic Wincc Opc Ua Client,Simatic Wincc Runtime Professional V16,Simatic Wincc Runtime Professional V17,Simatic Wincc Runtime Professional V18,Simatic Wincc Runtime Professional V19,Simatic Wincc Unified Opc Ua Server,Simatic Wincc V7.4,Simatic Wincc V7.5,Simatic Wincc V8.0,Sinumerik Mc,Sinumerik One,Siplus Et 200sp Cpu 1510sp F-1 Pn,Siplus Et 200sp Cpu 1510sp F-1 Pn Rail,Siplus Et 200sp Cpu 1510sp-1 Pn,Siplus Et 200sp Cpu 1510sp-1 Pn Rail,Siplus Et 200sp Cpu 1512sp F-1 Pn,Siplus Et 200sp Cpu 1512sp F-1 Pn Rail,Siplus Et 200sp Cpu 1512sp-1 Pn,Siplus Et 200sp Cpu 1512sp-1 Pn Rail,Siplus S7-1500 Cpu 1511-1 Pn,Siplus S7-1500 Cpu 1511-1 Pn T1 Rail,Siplus S7-1500 Cpu 1511-1 Pn Tx Rail,Siplus S7-1500 Cpu 1511f-1 Pn,Siplus S7-1500 Cpu 1513-1 Pn,Siplus S7-1500 Cpu 1513f-1 Pn,Siplus S7-1500 Cpu 1515f-2 Pn,Siplus S7-1500 Cpu 1515f-2 Pn Rail,Siplus S7-1500 Cpu 1515f-2 Pn T2 Rail,Siplus S7-1500 Cpu 1516-3 Pn/dp,Siplus S7-1500 Cpu 1516-3 Pn/dp Rail,Siplus S7-1500 Cpu 1516-3 Pn/dp Tx Rail,Siplus S7-1500 Cpu 1516f-3 Pn/dp,Siplus S7-1500 Cpu 1516f-3 Pn/dp Rail,Siplus S7-1500 Cpu 1518-4 Pn/dp,Siplus S7-1500 Cpu 1518-4 Pn/dp Mfp,Siplus S7-1500 Cpu 1518f-4 Pn/dp",7.5,HIGH,0.0005300000193528831,false,,false,false,false,,false,false,2023-09-12T10:15:00.000Z,0 CVE-2022-44731,https://securityvulnerability.io/vulnerability/CVE-2022-44731,Injection Flaw in SIMATIC WinCC OA from Siemens,"A critical vulnerability has been detected in various versions of Siemens' SIMATIC WinCC OA. This flaw permits authenticated remote attackers to inject custom arguments into the Ultralight Client backend application through the web interface. If exploited, it can allow attackers to manipulate application behavior, including opening unauthorized panels or initiating scripts with the attacker's credentials, posing serious risks to operational integrity and data security.",Siemens,"Simatic Wincc Oa V3.15,Simatic Wincc Oa V3.16,Simatic Wincc Oa V3.17,Simatic Wincc Oa V3.18",5.4,MEDIUM,0.0008200000156648457,false,,false,false,false,,false,false,2022-12-13T00:00:00.000Z,0 CVE-2022-33139,https://securityvulnerability.io/vulnerability/CVE-2022-33139,Client-Side Authentication Vulnerability in Cerberus DMS and Desigo Products by Siemens,"A vulnerability has been discovered in various Siemens products, including Cerberus DMS and Desigo systems, which utilize client-side only authentication. When server-side authentication or Kerberos is not activated, attackers can potentially masquerade as legitimate users or manipulate the client-server communication protocol without proper authentication checks. This flaw emphasizes the critical importance of implementing robust authentication mechanisms in both default and non-default configurations of affected products to safeguard against unauthorized access and exploitation.",Siemens,"Cerberus Dms,Desigo Cc,Desigo Cc Compact,Simatic Wincc Oa V3.16,Simatic Wincc Oa V3.17,Simatic Wincc Oa V3.18",9.8,CRITICAL,0.0016700000269338489,false,,false,false,false,,false,false,2022-06-21T00:00:00.000Z,0 CVE-2020-7580,https://securityvulnerability.io/vulnerability/CVE-2020-7580,,"A vulnerability has been identified in SIMATIC Automation Tool (All versions < V4 SP2), SIMATIC NET PC Software V14 (All versions < V14 SP1 Update 14), SIMATIC NET PC Software V15 (All versions), SIMATIC NET PC Software V16 (All versions < V16 Upd3), SIMATIC PCS neo (All versions < V3.0 SP1), SIMATIC ProSave (All versions < V17), SIMATIC S7-1500 Software Controller (All versions < V21.8), SIMATIC STEP 7 (TIA Portal) V13 (All versions < V13 SP2 Update 4), SIMATIC STEP 7 (TIA Portal) V14 (All versions < V14 SP1 Update 10), SIMATIC STEP 7 (TIA Portal) V15 (All versions < V15.1 Update 5), SIMATIC STEP 7 (TIA Portal) V16 (All versions < V16 Update 2), SIMATIC STEP 7 V5 (All versions < V5.6 SP2 HF3), SIMATIC WinCC OA V3.16 (All versions < V3.16 P018), SIMATIC WinCC OA V3.17 (All versions < V3.17 P003), SIMATIC WinCC Runtime Advanced (All versions < V16 Update 2), SIMATIC WinCC Runtime Professional V13 (All versions < V13 SP2 Update 4), SIMATIC WinCC Runtime Professional V14 (All versions < V14 SP1 Update 10), SIMATIC WinCC Runtime Professional V15 (All versions < V15.1 Update 5), SIMATIC WinCC Runtime Professional V16 (All versions < V16 Update 2), SIMATIC WinCC V7.4 (All versions < V7.4 SP1 Update 14), SIMATIC WinCC V7.5 (All versions < V7.5 SP1 Update 3), SINAMICS STARTER (All Versions < V5.4 HF2), SINAMICS Startdrive (All Versions < V16 Update 3), SINEC NMS (All versions < V1.0 SP2), SINEMA Server (All versions < V14 SP3), SINUMERIK ONE virtual (All Versions < V6.14), SINUMERIK Operate (All Versions < V6.14). A common component used by the affected applications regularly calls a helper binary with SYSTEM privileges while the call path is not quoted. This could allow a local attacker to execute arbitrary code with SYTEM privileges.",Siemens,"Simatic Automation Tool,Simatic Net Pc Software V14,Simatic Net Pc Software V15,Simatic Net Pc Software V16,Simatic Pcs Neo,Simatic Prosave,Simatic S7-1500 Software Controller,Simatic Step 7 (tia Portal) V13,Simatic Step 7 (tia Portal) V14,Simatic Step 7 (tia Portal) V15,Simatic Step 7 (tia Portal) V16,Simatic Step 7 V5,Simatic Wincc Oa V3.16,Simatic Wincc Oa V3.17,Simatic Wincc Runtime Advanced,Simatic Wincc Runtime Professional V13,Simatic Wincc Runtime Professional V14,Simatic Wincc Runtime Professional V15,Simatic Wincc Runtime Professional V16,Simatic Wincc V7.4,Simatic Wincc V7.5,Sinamics Starter,Sinamics Startdrive,Sinec Nms,Sinema Server,Sinumerik One Virtual,Sinumerik Operate",6.7,MEDIUM,0.0004600000102072954,false,,false,false,false,,false,false,2020-06-10T00:00:00.000Z,0 CVE-2019-10929,https://securityvulnerability.io/vulnerability/CVE-2019-10929,,"A vulnerability has been identified in SIMATIC CP 1626 (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants) (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions < V20.8), SIMATIC HMI Panel (incl. SIPLUS variants) (All versions), SIMATIC NET PC Software V14 (All versions < V14 SP1 Update 14), SIMATIC NET PC Software V15 (All versions), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions < V4.4.0), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions < V2.8.1), SIMATIC S7-1500 Software Controller (All versions < V20.8), SIMATIC S7-PLCSIM Advanced (All versions < V3.0), SIMATIC STEP 7 (TIA Portal) (All versions < V16), SIMATIC WinCC (TIA Portal) (All versions < V16), SIMATIC WinCC OA (All versions < V3.16 P013), SIMATIC WinCC Runtime Advanced (All versions < V16), SIMATIC WinCC Runtime Professional (All versions < V16), TIM 1531 IRC (incl. SIPLUS NET variants) (All versions < V2.1). Affected devices contain a message protection bypass vulnerability due to certain properties in the calculation used for integrity protection. This could allow an attacker in a Man-in-the-Middle position to modify network traffic sent on port 102/tcp to the affected devices.",Siemens,"Simatic Cp 1626,Simatic Et 200sp Open Controller Cpu 1515sp Pc (incl. Siplus Variants),Simatic Et 200sp Open Controller Cpu 1515sp Pc2 (incl. Siplus Variants),Simatic Hmi Panel (incl. Siplus Variants),Simatic Net Pc Software V14,Simatic Net Pc Software V15,Simatic S7-1200 Cpu Family (incl. Siplus Variants),Simatic S7-1500 Cpu Family (incl. Related Et200 Cpus And Siplus Variants),Simatic S7-1500 Software Controller,Simatic S7-plcsim Advanced,Simatic Step 7 (tia Portal),Simatic Wincc (tia Portal),Simatic Wincc Oa,Simatic Wincc Runtime Advanced,Simatic Wincc Runtime Professional,Tim 1531 Irc (incl. Siplus Net Variants)",5.9,MEDIUM,0.002360000042244792,false,,false,false,false,,false,false,2019-08-13T18:55:57.000Z,0 CVE-2019-6575,https://securityvulnerability.io/vulnerability/CVE-2019-6575,,"A vulnerability has been identified in SIMATIC CP 443-1 OPC UA (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions < V2.7), SIMATIC HMI Comfort Outdoor Panels 7"" & 15"" (incl. SIPLUS variants) (All versions < V15.1 Upd 4), SIMATIC HMI Comfort Panels 4"" - 22"" (incl. SIPLUS variants) (All versions < V15.1 Upd 4), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15.1 Upd 4), SIMATIC IPC DiagMonitor (All versions < V5.1.3), SIMATIC NET PC Software V13 (All versions), SIMATIC NET PC Software V14 (All versions < V14 SP1 Update 14), SIMATIC NET PC Software V15 (All versions), SIMATIC RF188C (All versions < V1.1.0), SIMATIC RF600R family (All versions < V3.2.1), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions >= V2.5 < V2.6.1), SIMATIC S7-1500 Software Controller (All versions between V2.5 (including) and V2.7 (excluding)), SIMATIC WinCC OA (All versions < V3.15 P018), SIMATIC WinCC Runtime Advanced (All versions < V15.1 Upd 4), SINEC NMS (All versions < V1.0 SP1), SINEMA Server (All versions < V14 SP2), SINUMERIK OPC UA Server (All versions < V2.1), TeleControl Server Basic (All versions < V3.1.1). Specially crafted network packets sent to affected devices on port 4840/tcp could allow an unauthenticated remote attacker to cause a denial of service condition of the OPC communication or crash the device. The security vulnerability could be exploited by an attacker with network access to the affected systems. Successful exploitation requires no system privileges and no user interaction. An attacker could use the vulnerability to compromise availability of the OPC communication.",Siemens,"Simatic Cp 443-1 Opc Ua,Simatic Et 200sp Open Controller Cpu 1515sp Pc2 (incl. Siplus Variants),Simatic Hmi Comfort Outdoor Panels 7"" & 15"" (incl. Siplus Variants),Simatic Hmi Comfort Panels 4"" - 22"" (incl. Siplus Variants),Simatic Hmi Ktp Mobile Panels Ktp400f, Ktp700, Ktp700f, Ktp900 And Ktp900f,Simatic Ipc Diagmonitor,Simatic Net Pc Software V13,Simatic Net Pc Software V14,Simatic Net Pc Software V15,Simatic Rf188c,Simatic Rf600r Family,Simatic S7-1500 Cpu Family (incl. Related Et200 Cpus And Siplus Variants),Simatic S7-1500 Software Controller,Simatic Wincc Oa,Simatic Wincc Runtime Advanced,Sinec Nms,Sinema Server,Sinumerik Opc Ua Server,Telecontrol Server Basic",7.5,HIGH,0.0017900000093504786,false,,false,false,false,,false,false,2019-04-17T13:40:24.000Z,0 CVE-2018-13799,https://securityvulnerability.io/vulnerability/CVE-2018-13799,,A vulnerability has been identified in SIMATIC WinCC OA V3.14 and prior (All versions < V3.14-P021). Improper access control to a data point of the affected product could allow an unauthenticated remote user to escalate its privileges in the context of SIMATIC WinCC OA V3.14. This vulnerability could be exploited by an attacker with network access to port 5678/TCP of the SIMATIC WinCC OA V3.14 server. Successful exploitation requires no user privileges and no user interaction. This vulnerability could allow an attacker to compromise integrity and availability of the SIMATIC WinCC OA system. At the time of advisory publication no public exploitation of this vulnerability was known.,Siemens,Simatic Wincc Oa V3.14 And Prior,9.1,CRITICAL,0.001550000044517219,false,,false,false,false,,false,false,2018-09-12T13:29:00.000Z,0 CVE-2018-4847,https://securityvulnerability.io/vulnerability/CVE-2018-4847,,A vulnerability has been identified in SIMATIC WinCC OA Operator iOS App (All versions < V1.4). Insufficient protection of sensitive information (e.g. session key for accessing server) in Siemens WinCC OA Operator iOS app could allow an attacker with physical access to the mobile device to read unencrypted data from the app's directory. Siemens provides mitigations to resolve the security issue.,Siemens,Simatic Wincc Oa Operator iOS App,4.6,MEDIUM,0.000539999979082495,false,,false,false,false,,false,false,2018-04-23T16:29:00.000Z,0 CVE-2018-4844,https://securityvulnerability.io/vulnerability/CVE-2018-4844,,"A vulnerability has been identified in SIMATIC WinCC OA UI for Android (All versions < V3.15.10), SIMATIC WinCC OA UI for iOS (All versions < V3.15.10). Insufficient limitation of CONTROL script capabilities could allow read and write access from one HMI project cache folder to other HMI project cache folders within the app's sandbox on the same mobile device. This includes HMI project cache folders of other configured WinCC OA servers. The security vulnerability could be exploited by an attacker who tricks an app user to connect to an attacker-controlled WinCC OA server. Successful exploitation requires user interaction and read/write access to the app's folder on a mobile device. The vulnerability could allow reading data from and writing data to the app's folder. At the time of advisory publication no public exploitation of this security vulnerability was known. Siemens confirms the security vulnerability and provides mitigations to resolve the security issue.",Siemens,"Simatic Wincc Oa Ui For Android, Simatic Wincc Oa Ui For iOS",6.7,MEDIUM,0.0004400000034365803,false,,false,false,false,,false,false,2018-03-20T00:00:00.000Z,0