cve,link,title,description,vendor,products,score,severity,epss,cisa,cisa_published,article,ransomware,exploited,poc,trended,trended_no_1,published,trended_score CVE-2023-30756,https://securityvulnerability.io/vulnerability/CVE-2023-30756,Vulnerability in SIMATIC Communication Processors and HMI Panels,"A security vulnerability has been identified in specific versions of SIMATIC CP communication processors and HMI Comfort Panels by Siemens. The web server on these devices fails to handle particular errors when the Expect HTTP request header is used, leading to a NULL dereference issue. This flaw allows a remote attacker to exploit the vulnerability without requiring additional privileges, thereby potentially initiating a denial of service condition. Users of affected products are advised to assess their systems and apply the necessary updates to mitigate risks associated with this vulnerability.",Siemens,"Simatic Cp 1242-7 V2 (incl. Siplus Variants),Simatic Cp 1243-1 (incl. Siplus Variants),Simatic Cp 1243-1 Dnp3 (incl. Siplus Variants),Simatic Cp 1243-1 Iec (incl. Siplus Variants),Simatic Cp 1243-7 Lte,Simatic Cp 1243-8 Irc,Simatic Hmi Comfort Panels (incl. Siplus Variants),Simatic Ipc Diagbase,Simatic Ipc Diagmonitor,Simatic Wincc Runtime Advanced,Siplus Tim 1531 Irc,Tim 1531 Irc",5.9,MEDIUM,0.0004299999854993075,false,,false,false,false,,false,false,2024-09-10T09:33:40.640Z,0 CVE-2023-30755,https://securityvulnerability.io/vulnerability/CVE-2023-30755,Denial of Service Vulnerability in Siemens SIMATIC Products,"A significant vulnerability exists within a range of Siemens SIMATIC devices that impacts how the integrated web server processes shutdown and reboot requests. This improper handling can result in certain resources not being correctly cleaned up. An attacker with elevated privileges could exploit this vulnerability remotely, potentially leading to a denial of service condition that disrupts the normal operation of the affected systems. Organizations using these products should assess their security posture in relation to this vulnerability and implement appropriate measures to mitigate any risks associated.",Siemens,"Simatic Cp 1242-7 V2 (incl. Siplus Variants),Simatic Cp 1243-1 (incl. Siplus Variants),Simatic Cp 1243-1 Dnp3 (incl. Siplus Variants),Simatic Cp 1243-1 Iec (incl. Siplus Variants),Simatic Cp 1243-7 Lte,Simatic Cp 1243-8 Irc,Simatic Hmi Comfort Panels (incl. Siplus Variants),Simatic Ipc Diagbase,Simatic Ipc Diagmonitor,Simatic Wincc Runtime Advanced,Siplus Tim 1531 Irc,Tim 1531 Irc",4.4,MEDIUM,0.0004299999854993075,false,,false,false,false,,false,false,2024-09-10T09:33:39.215Z,0 CVE-2023-28827,https://securityvulnerability.io/vulnerability/CVE-2023-28827,Denial of Service Vulnerability in Siemens SIMATIC Products,"A vulnerability has been found in multiple Siemens SIMATIC products due to the web server's failure to properly handle specific requests. This issue may cause a timeout in the watchdog system, leading to an unwanted cleanup of pointers. Consequently, a remote attacker could exploit this vulnerability to generate a denial of service condition, potentially disrupting operations and impacting system availability.",Siemens,"Simatic Cp 1242-7 V2 (incl. Siplus Variants),Simatic Cp 1243-1 (incl. Siplus Variants),Simatic Cp 1243-1 Dnp3 (incl. Siplus Variants),Simatic Cp 1243-1 Iec (incl. Siplus Variants),Simatic Cp 1243-7 Lte,Simatic Cp 1243-8 Irc,Simatic Hmi Comfort Panels (incl. Siplus Variants),Simatic Ipc Diagbase,Simatic Ipc Diagmonitor,Simatic Wincc Runtime Advanced,Siplus Tim 1531 Irc,Tim 1531 Irc",5.9,MEDIUM,0.0004299999854993075,false,,false,false,false,,false,false,2024-09-10T09:33:37.794Z,0 CVE-2023-46280,https://securityvulnerability.io/vulnerability/CVE-2023-46280,Out of Bounds Read Vulnerability in SIMATIC and TIA Portal Products by Siemens,"An out of bounds read vulnerability has been identified in multiple Siemens products, including the SIMATIC and TIA Portal series. This flaw can potentially lead to the crashing of the Windows kernel, resulting in a Blue Screen of Death (BSOD) error. Attackers could exploit this vulnerability to destabilize systems, impacting operational efficiency and safety within industrial environments. It is crucial for users of these products to be aware of this vulnerability and to implement necessary mitigations as outlined by Siemens.",Siemens,"Security Configuration Tool (sct),Simatic Automation Tool,Simatic Batch V9.1,Simatic Net Pc Software V16,Simatic Net Pc Software V17,Simatic Net Pc Software V18,Simatic Net Pc Software V19,Simatic Pcs 7 V9.1,Simatic Pdm V9.2,Simatic Route Control V9.1,Simatic S7-pct,Simatic Step 7 V5,Simatic Wincc Oa V3.17,Simatic Wincc Oa V3.18,Simatic Wincc Oa V3.19,Simatic Wincc Runtime Advanced,Simatic Wincc Runtime Professional V16,Simatic Wincc Runtime Professional V17,Simatic Wincc Runtime Professional V18,Simatic Wincc Runtime Professional V19,Simatic Wincc V7.4,Simatic Wincc V7.5,Simatic Wincc V8.0,Sinamics Startdrive,Sinec Nms,Sinumerik One Virtual,Sinumerik Plc Programming Tool,Tia Portal Cloud Connector,Totally Integrated Automation Portal (tia Portal) V15.1,Totally Integrated Automation Portal (tia Portal) V16,Totally Integrated Automation Portal (tia Portal) V17,Totally Integrated Automation Portal (tia Portal) V18,Totally Integrated Automation Portal (tia Portal) V19",6.5,MEDIUM,0.00044999999227002263,false,,false,false,false,,false,false,2024-05-14T10:01:52.069Z,0 CVE-2023-28831,https://securityvulnerability.io/vulnerability/CVE-2023-28831,Integer Overflow Issue in Siemens OPC UA Implementations,"The OPC UA implementations in Siemens products harbor an integer overflow vulnerability that can lead to an infinite loop during the certificate validation process. This condition could be exploited by an unauthenticated remote attacker utilizing a specially crafted certificate, resulting in a denial of service that impacts application availability and reliability.",Siemens,"Simatic Braumat,Simatic Cloud Connect 7 Cc712,Simatic Cloud Connect 7 Cc716,Simatic Comfort/mobile Rt,Simatic Drive Controller Cpu 1504d Tf,Simatic Drive Controller Cpu 1507d Tf,Simatic Et 200sp Open Controller Cpu 1515sp Pc2 (incl. Siplus Variants),Simatic Ipc Diagmonitor,Simatic Net Pc Software V14,Simatic Net Pc Software V16,Simatic Net Pc Software V17,Simatic Net Pc Software V18,Simatic Pcs 7 V9.1,Simatic Pcs Neo V4.0,Simatic S7-1500 Cpu 1510sp F-1 Pn,Simatic S7-1500 Cpu 1510sp-1 Pn,Simatic S7-1500 Cpu 1511-1 Pn,Simatic S7-1500 Cpu 1511c-1 Pn,Simatic S7-1500 Cpu 1511f-1 Pn,Simatic S7-1500 Cpu 1511t-1 Pn,Simatic S7-1500 Cpu 1511tf-1 Pn,Simatic S7-1500 Cpu 1512c-1 Pn,Simatic S7-1500 Cpu 1512sp F-1 Pn,Simatic S7-1500 Cpu 1512sp-1 Pn,Simatic S7-1500 Cpu 1513-1 Pn,Simatic S7-1500 Cpu 1513f-1 Pn,Simatic S7-1500 Cpu 1514sp F-2 Pn,Simatic S7-1500 Cpu 1514sp-2 Pn,Simatic S7-1500 Cpu 1514spt F-2 Pn,Simatic S7-1500 Cpu 1514spt-2 Pn,Simatic S7-1500 Cpu 1515-2 Pn,Simatic S7-1500 Cpu 1515f-2 Pn,Simatic S7-1500 Cpu 1515t-2 Pn,Simatic S7-1500 Cpu 1515tf-2 Pn,Simatic S7-1500 Cpu 1516-3 Pn/dp,Simatic S7-1500 Cpu 1516f-3 Pn/dp,Simatic S7-1500 Cpu 1516t-3 Pn/dp,Simatic S7-1500 Cpu 1516tf-3 Pn/dp,Simatic S7-1500 Cpu 1517-3 Pn/dp,Simatic S7-1500 Cpu 1517f-3 Pn/dp,Simatic S7-1500 Cpu 1517t-3 Pn/dp,Simatic S7-1500 Cpu 1517tf-3 Pn/dp,Simatic S7-1500 Cpu 1518-4 Pn/dp,Simatic S7-1500 Cpu 1518-4 Pn/dp Mfp,Simatic S7-1500 Cpu 1518f-4 Pn/dp,Simatic S7-1500 Cpu 1518f-4 Pn/dp Mfp,Simatic S7-1500 Cpu 1518t-4 Pn/dp,Simatic S7-1500 Cpu 1518tf-4 Pn/dp,Simatic S7-1500 Cpu S7-1518-4 Pn/dp Odk,Simatic S7-1500 Cpu S7-1518f-4 Pn/dp Odk,Simatic S7-1500 Et 200pro: Cpu 1513pro F-2 Pn,Simatic S7-1500 Et 200pro: Cpu 1513pro-2 Pn,Simatic S7-1500 Et 200pro: Cpu 1516pro F-2 Pn,Simatic S7-1500 Et 200pro: Cpu 1516pro-2 Pn,Simatic S7-1500 Software Controller V2,Simatic S7-1500 Software Controller V3,Simatic S7-plcsim Advanced,Simatic Sistar,Simatic Wincc Oa V3.17,Simatic Wincc Oa V3.18,Simatic Wincc Oa V3.19,Simatic Wincc Opc Ua Client,Simatic Wincc Runtime Professional V16,Simatic Wincc Runtime Professional V17,Simatic Wincc Runtime Professional V18,Simatic Wincc Runtime Professional V19,Simatic Wincc Unified Opc Ua Server,Simatic Wincc V7.4,Simatic Wincc V7.5,Simatic Wincc V8.0,Sinumerik Mc,Sinumerik One,Siplus Et 200sp Cpu 1510sp F-1 Pn,Siplus Et 200sp Cpu 1510sp F-1 Pn Rail,Siplus Et 200sp Cpu 1510sp-1 Pn,Siplus Et 200sp Cpu 1510sp-1 Pn Rail,Siplus Et 200sp Cpu 1512sp F-1 Pn,Siplus Et 200sp Cpu 1512sp F-1 Pn Rail,Siplus Et 200sp Cpu 1512sp-1 Pn,Siplus Et 200sp Cpu 1512sp-1 Pn Rail,Siplus S7-1500 Cpu 1511-1 Pn,Siplus S7-1500 Cpu 1511-1 Pn T1 Rail,Siplus S7-1500 Cpu 1511-1 Pn Tx Rail,Siplus S7-1500 Cpu 1511f-1 Pn,Siplus S7-1500 Cpu 1513-1 Pn,Siplus S7-1500 Cpu 1513f-1 Pn,Siplus S7-1500 Cpu 1515f-2 Pn,Siplus S7-1500 Cpu 1515f-2 Pn Rail,Siplus S7-1500 Cpu 1515f-2 Pn T2 Rail,Siplus S7-1500 Cpu 1516-3 Pn/dp,Siplus S7-1500 Cpu 1516-3 Pn/dp Rail,Siplus S7-1500 Cpu 1516-3 Pn/dp Tx Rail,Siplus S7-1500 Cpu 1516f-3 Pn/dp,Siplus S7-1500 Cpu 1516f-3 Pn/dp Rail,Siplus S7-1500 Cpu 1518-4 Pn/dp,Siplus S7-1500 Cpu 1518-4 Pn/dp Mfp,Siplus S7-1500 Cpu 1518f-4 Pn/dp",7.5,HIGH,0.0005300000193528831,false,,false,false,false,,false,false,2023-09-12T10:15:00.000Z,0 CVE-2022-30694,https://securityvulnerability.io/vulnerability/CVE-2022-30694,Cross-Site Request Forgery Vulnerability in Siemens Web Services,"An issue in the login endpoint of Siemens web services permits inadequate origin checking, allowing authenticated remote attackers to potentially exploit this weakness. By leveraging this vulnerability, attackers can orchestrate cross-site request forgery (CSRF) attacks, which could enable them to track the activities of legitimate users without their consent.",Siemens,"Simatic Drive Controller Cpu 1504d Tf,Simatic Drive Controller Cpu 1507d Tf,Simatic Et 200pro Im154-8 Pn/dp Cpu,Simatic Et 200pro Im154-8f Pn/dp Cpu,Simatic Et 200pro Im154-8fx Pn/dp Cpu,Simatic Et 200s Im151-8 Pn/dp Cpu,Simatic Et 200s Im151-8f Pn/dp Cpu,Simatic Et 200sp Open Controller Cpu 1515sp Pc2 (incl. Siplus Variants),Simatic Pc Station,Simatic S7-1200 Cpu Family (incl. Siplus Variants),Simatic S7-1500 Cpu 1510sp F-1 Pn,Simatic S7-1500 Cpu 1510sp-1 Pn,Simatic S7-1500 Cpu 1511-1 Pn,Simatic S7-1500 Cpu 1511c-1 Pn,Simatic S7-1500 Cpu 1511f-1 Pn,Simatic S7-1500 Cpu 1511t-1 Pn,Simatic S7-1500 Cpu 1511tf-1 Pn,Simatic S7-1500 Cpu 1512c-1 Pn,Simatic S7-1500 Cpu 1512sp F-1 Pn,Simatic S7-1500 Cpu 1512sp-1 Pn,Simatic S7-1500 Cpu 1513-1 Pn,Simatic S7-1500 Cpu 1513f-1 Pn,Simatic S7-1500 Cpu 1513r-1 Pn,Simatic S7-1500 Cpu 1515-2 Pn,Simatic S7-1500 Cpu 1515f-2 Pn,Simatic S7-1500 Cpu 1515r-2 Pn,Simatic S7-1500 Cpu 1515t-2 Pn,Simatic S7-1500 Cpu 1515tf-2 Pn,Simatic S7-1500 Cpu 1516-3 Pn/dp,Simatic S7-1500 Cpu 1516f-3 Pn/dp,Simatic S7-1500 Cpu 1516t-3 Pn/dp,Simatic S7-1500 Cpu 1516tf-3 Pn/dp,Simatic S7-1500 Cpu 1517-3 Pn/dp,Simatic S7-1500 Cpu 1517f-3 Pn/dp,Simatic S7-1500 Cpu 1517h-3 Pn,Simatic S7-1500 Cpu 1517t-3 Pn/dp,Simatic S7-1500 Cpu 1517tf-3 Pn/dp,Simatic S7-1500 Cpu 1518-4 Pn/dp,Simatic S7-1500 Cpu 1518-4 Pn/dp Mfp,Simatic S7-1500 Cpu 1518f-4 Pn/dp,Simatic S7-1500 Cpu 1518f-4 Pn/dp Mfp,Simatic S7-1500 Cpu 1518hf-4 Pn,Simatic S7-1500 Cpu 1518t-4 Pn/dp,Simatic S7-1500 Cpu 1518tf-4 Pn/dp,Simatic S7-1500 Cpu S7-1518-4 Pn/dp Odk,Simatic S7-1500 Cpu S7-1518f-4 Pn/dp Odk,Simatic S7-1500 Et 200pro: Cpu 1513pro F-2 Pn,Simatic S7-1500 Et 200pro: Cpu 1513pro-2 Pn,Simatic S7-1500 Et 200pro: Cpu 1516pro F-2 Pn,Simatic S7-1500 Et 200pro: Cpu 1516pro-2 Pn,Simatic S7-1500 Software Controller V2,Simatic S7-300 Cpu 314c-2 Pn/dp,Simatic S7-300 Cpu 315-2 Pn/dp,Simatic S7-300 Cpu 315f-2 Pn/dp,Simatic S7-300 Cpu 315t-3 Pn/dp,Simatic S7-300 Cpu 317-2 Pn/dp,Simatic S7-300 Cpu 317f-2 Pn/dp,Simatic S7-300 Cpu 317t-3 Pn/dp,Simatic S7-300 Cpu 317tf-3 Pn/dp,Simatic S7-300 Cpu 319-3 Pn/dp,Simatic S7-300 Cpu 319f-3 Pn/dp,Simatic S7-400 Pn/dp V6 Cpu Family (incl. Siplus Variants),Simatic S7-400 Pn/dp V7 Cpu Family (incl. Siplus Variants),Simatic S7-plcsim Advanced,Simatic Wincc Runtime Advanced,Sinumerik One,Siplus Et 200s Im151-8 Pn/dp Cpu,Siplus Et 200s Im151-8f Pn/dp Cpu,Siplus Et 200sp Cpu 1510sp F-1 Pn,Siplus Et 200sp Cpu 1510sp F-1 Pn Rail,Siplus Et 200sp Cpu 1510sp-1 Pn,Siplus Et 200sp Cpu 1510sp-1 Pn Rail,Siplus Et 200sp Cpu 1512sp F-1 Pn,Siplus Et 200sp Cpu 1512sp F-1 Pn Rail,Siplus Et 200sp Cpu 1512sp-1 Pn,Siplus Et 200sp Cpu 1512sp-1 Pn Rail,Siplus S7-1500 Cpu 1511-1 Pn,Siplus S7-1500 Cpu 1511-1 Pn T1 Rail,Siplus S7-1500 Cpu 1511-1 Pn Tx Rail,Siplus S7-1500 Cpu 1511f-1 Pn,Siplus S7-1500 Cpu 1513-1 Pn,Siplus S7-1500 Cpu 1513f-1 Pn,Siplus S7-1500 Cpu 1515f-2 Pn,Siplus S7-1500 Cpu 1515f-2 Pn Rail,Siplus S7-1500 Cpu 1515f-2 Pn T2 Rail,Siplus S7-1500 Cpu 1515r-2 Pn,Siplus S7-1500 Cpu 1515r-2 Pn Tx Rail,Siplus S7-1500 Cpu 1516-3 Pn/dp,Siplus S7-1500 Cpu 1516-3 Pn/dp Rail,Siplus S7-1500 Cpu 1516-3 Pn/dp Tx Rail,Siplus S7-1500 Cpu 1516f-3 Pn/dp,Siplus S7-1500 Cpu 1516f-3 Pn/dp Rail,Siplus S7-1500 Cpu 1517h-3 Pn,Siplus S7-1500 Cpu 1518-4 Pn/dp,Siplus S7-1500 Cpu 1518-4 Pn/dp Mfp,Siplus S7-1500 Cpu 1518f-4 Pn/dp,Siplus S7-1500 Cpu 1518hf-4 Pn,Siplus S7-300 Cpu 314c-2 Pn/dp,Siplus S7-300 Cpu 315-2 Pn/dp,Siplus S7-300 Cpu 315f-2 Pn/dp,Siplus S7-300 Cpu 317-2 Pn/dp,Siplus S7-300 Cpu 317f-2 Pn/dp",6.5,MEDIUM,0.0004600000102072954,false,,false,false,false,,false,false,2022-11-08T00:00:00.000Z,0 CVE-2021-27386,https://securityvulnerability.io/vulnerability/CVE-2021-27386,,"A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\"" & 15\"" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\"" & 15\"" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI Comfort Panels V15 4\"" - 22\"" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\"" - 22\"" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (All versions < V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (All versions < V16 Update 4), SINAMICS GH150 (All versions), SINAMICS GL150 (with option X30) (All versions), SINAMICS GM150 (with option X30) (All versions), SINAMICS SH150 (All versions), SINAMICS SL150 (All versions), SINAMICS SM120 (All versions), SINAMICS SM150 (All versions), SINAMICS SM150i (All versions). SmartVNC has a heap allocation leak vulnerability in the device layout handler on client side, which could result in a Denial-of-Service condition.",Siemens,"Simatic Hmi Comfort Outdoor Panels V15 7\"" & 15\"" (incl. Siplus Variants),Simatic Hmi Comfort Outdoor Panels V16 7\"" & 15\"" (incl. Siplus Variants),Simatic Hmi Comfort Panels V15 4\"" - 22\"" (incl. Siplus Variants),Simatic Hmi Comfort Panels V16 4\"" - 22\"" (incl. Siplus Variants),Simatic Hmi Ktp Mobile Panels V15 Ktp400f, Ktp700, Ktp700f, Ktp900 And Ktp900f,Simatic Hmi Ktp Mobile Panels V16 Ktp400f, Ktp700, Ktp700f, Ktp900 And Ktp900f,Simatic Wincc Runtime Advanced V15,Simatic Wincc Runtime Advanced V16,Sinamics Gh150,Sinamics Gl150 (with Option X30),Sinamics Gm150 (with Option X30),Sinamics Sh150,Sinamics Sl150,Sinamics Sm120,Sinamics Sm150,Sinamics Sm150i",7.5,HIGH,0.004809999838471413,false,,false,false,false,,false,false,2021-05-12T13:18:23.000Z,0 CVE-2021-27385,https://securityvulnerability.io/vulnerability/CVE-2021-27385,,"A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\"" & 15\"" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\"" & 15\"" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI Comfort Panels V15 4\"" - 22\"" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\"" - 22\"" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (All versions < V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (All versions < V16 Update 4), SINAMICS GH150 (All versions), SINAMICS GL150 (with option X30) (All versions), SINAMICS GM150 (with option X30) (All versions), SINAMICS SH150 (All versions), SINAMICS SL150 (All versions), SINAMICS SM120 (All versions), SINAMICS SM150 (All versions), SINAMICS SM150i (All versions). A remote attacker could send specially crafted packets to SmartVNC device layout handler on client side, which could influence the amount of resources consumed and result in a Denial-of-Service (infinite loop) condition.",Siemens,"Simatic Hmi Comfort Outdoor Panels V15 7\"" & 15\"" (incl. Siplus Variants),Simatic Hmi Comfort Outdoor Panels V16 7\"" & 15\"" (incl. Siplus Variants),Simatic Hmi Comfort Panels V15 4\"" - 22\"" (incl. Siplus Variants),Simatic Hmi Comfort Panels V16 4\"" - 22\"" (incl. Siplus Variants),Simatic Hmi Ktp Mobile Panels V15 Ktp400f, Ktp700, Ktp700f, Ktp900 And Ktp900f,Simatic Hmi Ktp Mobile Panels V16 Ktp400f, Ktp700, Ktp700f, Ktp900 And Ktp900f,Simatic Wincc Runtime Advanced V15,Simatic Wincc Runtime Advanced V16,Sinamics Gh150,Sinamics Gl150 (with Option X30),Sinamics Gm150 (with Option X30),Sinamics Sh150,Sinamics Sl150,Sinamics Sm120,Sinamics Sm150,Sinamics Sm150i",7.5,HIGH,0.0029299999587237835,false,,false,false,false,,false,false,2021-05-12T13:18:23.000Z,0 CVE-2021-27384,https://securityvulnerability.io/vulnerability/CVE-2021-27384,,"A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\"" & 15\"" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\"" & 15\"" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI Comfort Panels V15 4\"" - 22\"" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\"" - 22\"" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (All versions < V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (All versions < V16 Update 4), SINAMICS GH150 (All versions), SINAMICS GL150 (with option X30) (All versions), SINAMICS GM150 (with option X30) (All versions), SINAMICS SH150 (All versions), SINAMICS SL150 (All versions), SINAMICS SM120 (All versions), SINAMICS SM150 (All versions), SINAMICS SM150i (All versions). SmartVNC has an out-of-bounds memory access vulnerability in the device layout handler, represented by a binary data stream on client side, which can potentially result in code execution.",Siemens,"Simatic Hmi Comfort Outdoor Panels V15 7\"" & 15\"" (incl. Siplus Variants),Simatic Hmi Comfort Outdoor Panels V16 7\"" & 15\"" (incl. Siplus Variants),Simatic Hmi Comfort Panels V15 4\"" - 22\"" (incl. Siplus Variants),Simatic Hmi Comfort Panels V16 4\"" - 22\"" (incl. Siplus Variants),Simatic Hmi Ktp Mobile Panels V15 Ktp400f, Ktp700, Ktp700f, Ktp900 And Ktp900f,Simatic Hmi Ktp Mobile Panels V16 Ktp400f, Ktp700, Ktp700f, Ktp900 And Ktp900f,Simatic Wincc Runtime Advanced V15,Simatic Wincc Runtime Advanced V16,Sinamics Gh150,Sinamics Gl150 (with Option X30),Sinamics Gm150 (with Option X30),Sinamics Sh150,Sinamics Sl150,Sinamics Sm120,Sinamics Sm150,Sinamics Sm150i",9.8,CRITICAL,0.005330000072717667,false,,false,false,false,,false,false,2021-05-12T13:18:22.000Z,0 CVE-2021-27383,https://securityvulnerability.io/vulnerability/CVE-2021-27383,,"A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\"" & 15\"" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\"" & 15\"" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI Comfort Panels V15 4\"" - 22\"" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\"" - 22\"" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (All versions < V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (All versions < V16 Update 4), SINAMICS GH150 (All versions), SINAMICS GL150 (with option X30) (All versions), SINAMICS GM150 (with option X30) (All versions), SINAMICS SH150 (All versions), SINAMICS SL150 (All versions), SINAMICS SM120 (All versions), SINAMICS SM150 (All versions), SINAMICS SM150i (All versions). SmartVNC has a heap allocation leak vulnerability in the server Tight encoder, which could result in a Denial-of-Service condition.",Siemens,"Simatic Hmi Comfort Outdoor Panels V15 7\"" & 15\"" (incl. Siplus Variants),Simatic Hmi Comfort Outdoor Panels V16 7\"" & 15\"" (incl. Siplus Variants),Simatic Hmi Comfort Panels V15 4\"" - 22\"" (incl. Siplus Variants),Simatic Hmi Comfort Panels V16 4\"" - 22\"" (incl. Siplus Variants),Simatic Hmi Ktp Mobile Panels V15 Ktp400f, Ktp700, Ktp700f, Ktp900 And Ktp900f,Simatic Hmi Ktp Mobile Panels V16 Ktp400f, Ktp700, Ktp700f, Ktp900 And Ktp900f,Simatic Wincc Runtime Advanced V15,Simatic Wincc Runtime Advanced V16,Sinamics Gh150,Sinamics Gl150 (with Option X30),Sinamics Gm150 (with Option X30),Sinamics Sh150,Sinamics Sl150,Sinamics Sm120,Sinamics Sm150,Sinamics Sm150i",7.5,HIGH,0.0016599999507889152,false,,false,false,false,,false,false,2021-05-12T13:18:22.000Z,0 CVE-2021-25661,https://securityvulnerability.io/vulnerability/CVE-2021-25661,,"A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\"" & 15\"" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\"" & 15\"" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI Comfort Panels V15 4\"" - 22\"" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\"" - 22\"" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (All versions < V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (All versions < V16 Update 4). SmartVNC has an out-of-bounds memory access vulnerability that could be triggered on the client side when sending data from the server, which could result in a Denial-of-Service condition.",Siemens,"Simatic Hmi Comfort Outdoor Panels V15 7\"" & 15\"" (incl. Siplus Variants),Simatic Hmi Comfort Outdoor Panels V16 7\"" & 15\"" (incl. Siplus Variants),Simatic Hmi Comfort Panels V15 4\"" - 22\"" (incl. Siplus Variants),Simatic Hmi Comfort Panels V16 4\"" - 22\"" (incl. Siplus Variants),Simatic Hmi Ktp Mobile Panels V15 Ktp400f, Ktp700, Ktp700f, Ktp900 And Ktp900f,Simatic Hmi Ktp Mobile Panels V16 Ktp400f, Ktp700, Ktp700f, Ktp900 And Ktp900f,Simatic Wincc Runtime Advanced V15,Simatic Wincc Runtime Advanced V16",7.5,HIGH,0.0014600000577047467,false,,false,false,false,,false,false,2021-05-12T13:18:22.000Z,0 CVE-2021-25662,https://securityvulnerability.io/vulnerability/CVE-2021-25662,,"A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\"" & 15\"" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\"" & 15\"" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI Comfort Panels V15 4\"" - 22\"" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\"" - 22\"" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (All versions < V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (All versions < V16 Update 4). SmartVNC client fails to handle an exception properly if the program execution process is modified after sending a packet from the server, which could result in a Denial-of-Service condition.",Siemens,"Simatic Hmi Comfort Outdoor Panels V15 7\"" & 15\"" (incl. Siplus Variants),Simatic Hmi Comfort Outdoor Panels V16 7\"" & 15\"" (incl. Siplus Variants),Simatic Hmi Comfort Panels V15 4\"" - 22\"" (incl. Siplus Variants),Simatic Hmi Comfort Panels V16 4\"" - 22\"" (incl. Siplus Variants),Simatic Hmi Ktp Mobile Panels V15 Ktp400f, Ktp700, Ktp700f, Ktp900 And Ktp900f,Simatic Hmi Ktp Mobile Panels V16 Ktp400f, Ktp700, Ktp700f, Ktp900 And Ktp900f,Simatic Wincc Runtime Advanced V15,Simatic Wincc Runtime Advanced V16",7.5,HIGH,0.008379999548196793,false,,false,false,false,,false,false,2021-05-12T13:18:22.000Z,0 CVE-2021-25660,https://securityvulnerability.io/vulnerability/CVE-2021-25660,,"A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\"" & 15\"" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\"" & 15\"" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI Comfort Panels V15 4\"" - 22\"" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\"" - 22\"" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (All versions < V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (All versions < V16 Update 4). SmartVNC has an out-of-bounds memory access vulnerability that could be triggered on the server side when sending data from the client, which could result in a Denial-of-Service condition.",Siemens,"Simatic Hmi Comfort Outdoor Panels V15 7\"" & 15\"" (incl. Siplus Variants),Simatic Hmi Comfort Outdoor Panels V16 7\"" & 15\"" (incl. Siplus Variants),Simatic Hmi Comfort Panels V15 4\"" - 22\"" (incl. Siplus Variants),Simatic Hmi Comfort Panels V16 4\"" - 22\"" (incl. Siplus Variants),Simatic Hmi Ktp Mobile Panels V15 Ktp400f, Ktp700, Ktp700f, Ktp900 And Ktp900f,Simatic Hmi Ktp Mobile Panels V16 Ktp400f, Ktp700, Ktp700f, Ktp900 And Ktp900f,Simatic Wincc Runtime Advanced V15,Simatic Wincc Runtime Advanced V16",7.5,HIGH,0.0014700000174343586,false,,false,false,false,,false,false,2021-05-12T13:18:22.000Z,0 CVE-2020-7592,https://securityvulnerability.io/vulnerability/CVE-2020-7592,,"A vulnerability has been identified in SIMATIC HMI Basic Panels 1st Generation (incl. SIPLUS variants) (All versions), SIMATIC HMI Basic Panels 2nd Generation (incl. SIPLUS variants) (All versions), SIMATIC HMI Comfort Panels (incl. SIPLUS variants) (All versions), SIMATIC HMI KTP700F Mobile Arctic (All versions), SIMATIC HMI Mobile Panels 2nd Generation (All versions), SIMATIC WinCC Runtime Advanced (All versions). Unencrypted communication between the configuration software and the respective device could allow an attacker to capture potential plain text communication and have access to sensitive information.",Siemens,"Simatic Hmi Basic Panels 1st Generation (incl. Siplus Variants),Simatic Hmi Basic Panels 2nd Generation (incl. Siplus Variants),Simatic Hmi Comfort Panels (incl. Siplus Variants),Simatic Hmi Ktp700f Mobile Arctic,Simatic Hmi Mobile Panels 2nd Generation,Simatic Wincc Runtime Advanced",6.5,MEDIUM,0.0005799999926239252,false,,false,false,false,,false,false,2020-07-14T13:18:05.000Z,0 CVE-2020-7580,https://securityvulnerability.io/vulnerability/CVE-2020-7580,,"A vulnerability has been identified in SIMATIC Automation Tool (All versions < V4 SP2), SIMATIC NET PC Software V14 (All versions < V14 SP1 Update 14), SIMATIC NET PC Software V15 (All versions), SIMATIC NET PC Software V16 (All versions < V16 Upd3), SIMATIC PCS neo (All versions < V3.0 SP1), SIMATIC ProSave (All versions < V17), SIMATIC S7-1500 Software Controller (All versions < V21.8), SIMATIC STEP 7 (TIA Portal) V13 (All versions < V13 SP2 Update 4), SIMATIC STEP 7 (TIA Portal) V14 (All versions < V14 SP1 Update 10), SIMATIC STEP 7 (TIA Portal) V15 (All versions < V15.1 Update 5), SIMATIC STEP 7 (TIA Portal) V16 (All versions < V16 Update 2), SIMATIC STEP 7 V5 (All versions < V5.6 SP2 HF3), SIMATIC WinCC OA V3.16 (All versions < V3.16 P018), SIMATIC WinCC OA V3.17 (All versions < V3.17 P003), SIMATIC WinCC Runtime Advanced (All versions < V16 Update 2), SIMATIC WinCC Runtime Professional V13 (All versions < V13 SP2 Update 4), SIMATIC WinCC Runtime Professional V14 (All versions < V14 SP1 Update 10), SIMATIC WinCC Runtime Professional V15 (All versions < V15.1 Update 5), SIMATIC WinCC Runtime Professional V16 (All versions < V16 Update 2), SIMATIC WinCC V7.4 (All versions < V7.4 SP1 Update 14), SIMATIC WinCC V7.5 (All versions < V7.5 SP1 Update 3), SINAMICS STARTER (All Versions < V5.4 HF2), SINAMICS Startdrive (All Versions < V16 Update 3), SINEC NMS (All versions < V1.0 SP2), SINEMA Server (All versions < V14 SP3), SINUMERIK ONE virtual (All Versions < V6.14), SINUMERIK Operate (All Versions < V6.14). A common component used by the affected applications regularly calls a helper binary with SYSTEM privileges while the call path is not quoted. This could allow a local attacker to execute arbitrary code with SYTEM privileges.",Siemens,"Simatic Automation Tool,Simatic Net Pc Software V14,Simatic Net Pc Software V15,Simatic Net Pc Software V16,Simatic Pcs Neo,Simatic Prosave,Simatic S7-1500 Software Controller,Simatic Step 7 (tia Portal) V13,Simatic Step 7 (tia Portal) V14,Simatic Step 7 (tia Portal) V15,Simatic Step 7 (tia Portal) V16,Simatic Step 7 V5,Simatic Wincc Oa V3.16,Simatic Wincc Oa V3.17,Simatic Wincc Runtime Advanced,Simatic Wincc Runtime Professional V13,Simatic Wincc Runtime Professional V14,Simatic Wincc Runtime Professional V15,Simatic Wincc Runtime Professional V16,Simatic Wincc V7.4,Simatic Wincc V7.5,Sinamics Starter,Sinamics Startdrive,Sinec Nms,Sinema Server,Sinumerik One Virtual,Sinumerik Operate",6.7,MEDIUM,0.0004600000102072954,false,,false,false,false,,false,false,2020-06-10T00:00:00.000Z,0 CVE-2019-10929,https://securityvulnerability.io/vulnerability/CVE-2019-10929,,"A vulnerability has been identified in SIMATIC CP 1626 (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants) (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions < V20.8), SIMATIC HMI Panel (incl. SIPLUS variants) (All versions), SIMATIC NET PC Software V14 (All versions < V14 SP1 Update 14), SIMATIC NET PC Software V15 (All versions), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions < V4.4.0), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions < V2.8.1), SIMATIC S7-1500 Software Controller (All versions < V20.8), SIMATIC S7-PLCSIM Advanced (All versions < V3.0), SIMATIC STEP 7 (TIA Portal) (All versions < V16), SIMATIC WinCC (TIA Portal) (All versions < V16), SIMATIC WinCC OA (All versions < V3.16 P013), SIMATIC WinCC Runtime Advanced (All versions < V16), SIMATIC WinCC Runtime Professional (All versions < V16), TIM 1531 IRC (incl. SIPLUS NET variants) (All versions < V2.1). Affected devices contain a message protection bypass vulnerability due to certain properties in the calculation used for integrity protection. This could allow an attacker in a Man-in-the-Middle position to modify network traffic sent on port 102/tcp to the affected devices.",Siemens,"Simatic Cp 1626,Simatic Et 200sp Open Controller Cpu 1515sp Pc (incl. Siplus Variants),Simatic Et 200sp Open Controller Cpu 1515sp Pc2 (incl. Siplus Variants),Simatic Hmi Panel (incl. Siplus Variants),Simatic Net Pc Software V14,Simatic Net Pc Software V15,Simatic S7-1200 Cpu Family (incl. Siplus Variants),Simatic S7-1500 Cpu Family (incl. Related Et200 Cpus And Siplus Variants),Simatic S7-1500 Software Controller,Simatic S7-plcsim Advanced,Simatic Step 7 (tia Portal),Simatic Wincc (tia Portal),Simatic Wincc Oa,Simatic Wincc Runtime Advanced,Simatic Wincc Runtime Professional,Tim 1531 Irc (incl. Siplus Net Variants)",5.9,MEDIUM,0.002360000042244792,false,,false,false,false,,false,false,2019-08-13T18:55:57.000Z,0 CVE-2019-6572,https://securityvulnerability.io/vulnerability/CVE-2019-6572,,"A vulnerability has been identified in SIMATIC HMI Comfort Panels 4"" - 22"" (All versions < V15.1 Update 1), SIMATIC HMI Comfort Outdoor Panels 7"" & 15"" (All versions < V15.1 Update 1), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 und KTP900F (All versions < V15.1 Update 1), SIMATIC WinCC Runtime Advanced (All versions < V15.1 Update 1), SIMATIC WinCC Runtime Professional (All versions < V15.1 Update 1), SIMATIC WinCC (TIA Portal) (All versions < V15.1 Update 1), SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel) (All versions). The affected device offered SNMP read and write capacities with a publicly know hardcoded community string. The security vulnerability could be exploited by an attacker with network access to the affected device. Successful exploitation requires no system privileges and no user interaction. An attacker could use the vulnerability to compromise confidentiality and integrity of the affected system. At the time of advisory publication no public exploitation of this security vulnerability was known.",Siemens,"Simatic Hmi Comfort Panels 4"" - 22"",Simatic Hmi Comfort Outdoor Panels 7"" & 15"",Simatic Hmi Ktp Mobile Panels Ktp400f, Ktp700, Ktp700f, Ktp900 Und Ktp900f,Simatic Wincc Runtime Advanced,Simatic Wincc Runtime Professional,Simatic Wincc (tia Portal),Simatic Hmi Classic Devices (tp/mp/op/mp Mobile Panel)",9.1,CRITICAL,0.003800000064074993,false,,false,false,false,,false,false,2019-05-14T19:54:48.000Z,0 CVE-2019-6576,https://securityvulnerability.io/vulnerability/CVE-2019-6576,,"A vulnerability has been identified in SIMATIC HMI Comfort Panels 4"" - 22"" (All versions < V15.1 Update 1), SIMATIC HMI Comfort Outdoor Panels 7"" & 15"" (All versions < V15.1 Update 1), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 und KTP900F (All versions < V15.1 Update 1), SIMATIC WinCC Runtime Advanced (All versions < V15.1 Update 1), SIMATIC WinCC Runtime Professional (All versions < V15.1 Update 1), SIMATIC WinCC (TIA Portal) (All versions < V15.1 Update 1), SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel) (All versions). An attacker with network access to affected devices could potentially obtain a TLS session key. If the attacker is able to observe TLS traffic between a legitimate user and the device, then the attacker could decrypt the TLS traffic. The security vulnerability could be exploited by an attacker who has network access to the web interface of the device and who is able to observe TLS traffic between legitimate users and the web interface of the affected device. The vulnerability could impact the confidentiality of the communication between the affected device and a legitimate user. At the time of advisory publication no public exploitation of the security vulnerability was known.",Siemens,"Simatic Hmi Comfort Panels 4"" - 22"",Simatic Hmi Comfort Outdoor Panels 7"" & 15"",Simatic Hmi Ktp Mobile Panels Ktp400f, Ktp700, Ktp700f, Ktp900 Und Ktp900f,Simatic Wincc Runtime Advanced,Simatic Wincc Runtime Professional,Simatic Wincc (tia Portal),Simatic Hmi Classic Devices (tp/mp/op/mp Mobile Panel)",7.5,HIGH,0.0013500000350177288,false,,false,false,false,,false,false,2019-05-14T19:54:48.000Z,0 CVE-2019-6577,https://securityvulnerability.io/vulnerability/CVE-2019-6577,,"A vulnerability has been identified in SIMATIC HMI Comfort Panels 4"" - 22"" (All versions < V15.1 Update 1), SIMATIC HMI Comfort Outdoor Panels 7"" & 15"" (All versions < V15.1 Update 1), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 und KTP900F (All versions < V15.1 Update 1), SIMATIC WinCC Runtime Advanced (All versions < V15.1 Update 1), SIMATIC WinCC Runtime Professional (All versions < V15.1 Update 1), SIMATIC WinCC (TIA Portal) (All versions < V15.1 Update 1), SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel) (All versions). The integrated web server could allow Cross-Site Scripting (XSS) attacks if an attacker is able to modify particular parts of the device configuration via SNMP. The security vulnerability could be exploited by an attacker with network access to the affected system. Successful exploitation requires system privileges and user interaction. An attacker could use the vulnerability to compromise confidentiality and the integrity of the affected system. At the stage of publishing this security advisory no public exploitation is known.",Siemens,"Simatic Hmi Comfort Panels 4"" - 22"",Simatic Hmi Comfort Outdoor Panels 7"" & 15"",Simatic Hmi Ktp Mobile Panels Ktp400f, Ktp700, Ktp700f, Ktp900 Und Ktp900f,Simatic Wincc Runtime Advanced,Simatic Wincc Runtime Professional,Simatic Wincc (tia Portal),Simatic Hmi Classic Devices (tp/mp/op/mp Mobile Panel)",5.4,MEDIUM,0.0006600000197067857,false,,false,false,false,,false,false,2019-05-14T19:54:48.000Z,0 CVE-2019-6568,https://securityvulnerability.io/vulnerability/CVE-2019-6568,,"The webserver of the affected devices contains a vulnerability that may lead to a denial of service condition. An attacker may cause a denial of service situation which leads to a restart of the webserver of the affected device. The security vulnerability could be exploited by an attacker with network access to the affected systems. Successful exploitation requires no system privileges and no user interaction. An attacker could use the vulnerability to compromise availability of the device.",Siemens,"Simatic Cp 1604,Simatic Cp 1616,Simatic Cp 343-1 Advanced,Simatic Cp 443-1,Simatic Cp 443-1 Advanced,Simatic Cp 443-1 Opc Ua,Simatic Et 200pro Im154-8 Pn/dp Cpu,Simatic Et 200pro Im154-8f Pn/dp Cpu,Simatic Et 200pro Im154-8fx Pn/dp Cpu,Simatic Et 200s Im151-8 Pn/dp Cpu,Simatic Et 200s Im151-8f Pn/dp Cpu,Simatic Et 200sp Open Controller Cpu 1515sp Pc (incl. Siplus Variants),Simatic Et 200sp Open Controller Cpu 1515sp Pc2 (incl. Siplus Variants),Simatic Hmi Comfort Outdoor Panels 7"" & 15"" (incl. Siplus Variants),Simatic Hmi Comfort Panels 4"" - 22"" (incl. Siplus Variants),Simatic Hmi Ktp Mobile Panels Ktp400f, Ktp700, Ktp700f, Ktp900 And Ktp900f,Simatic Ipc Diagmonitor,Simatic Rf182c,Simatic Rf185c,Simatic Rf186c,Simatic Rf188c,Simatic Rf600r Family,Simatic Rfid 181eip,Simatic S7-1500 Cpu Family (incl. Related Et200 Cpus And Siplus Variants),Simatic S7-1500 Software Controller,Simatic S7-300 Cpu 314c-2 Pn/dp,Simatic S7-300 Cpu 315-2 Pn/dp,Simatic S7-300 Cpu 315f-2 Pn/dp,Simatic S7-300 Cpu 315t-3 Pn/dp,Simatic S7-300 Cpu 317-2 Pn/dp,Simatic S7-300 Cpu 317f-2 Pn/dp,Simatic S7-300 Cpu 317t-3 Pn/dp,Simatic S7-300 Cpu 317tf-3 Pn/dp,Simatic S7-300 Cpu 319-3 Pn/dp,Simatic S7-300 Cpu 319f-3 Pn/dp,Simatic S7-400 Pn/dp V6 And Below Cpu Family (incl. Siplus Variants),Simatic S7-400 Pn/dp V7 Cpu Family (incl. Siplus Variants),Simatic S7-plcsim Advanced,Simatic Teleservice Adapter Ie Advanced,Simatic Teleservice Adapter Ie Basic,Simatic Teleservice Adapter Ie Standard,Simatic Winac Rtx 2010,Simatic Winac Rtx F 2010,Simatic Wincc Runtime Advanced,Simocode Pro V Ethernet/ip (incl. Siplus Variants),Simocode Pro V Profinet (incl. Siplus Variants),Sinamics G130 V4.6 Control Unit,Sinamics G130 V4.7 Control Unit,Sinamics G130 V4.7 Sp1 Control Unit,Sinamics G130 V4.8 Control Unit,Sinamics G130 V5.1 Control Unit,Sinamics G130 V5.1 Sp1 Control Unit,Sinamics G150 V4.6 Control Unit,Sinamics G150 V4.7 Control Unit,Sinamics G150 V4.7 Sp1 Control Unit,Sinamics G150 V4.8 Control Unit,Sinamics G150 V5.1 Control Unit,Sinamics G150 V5.1 Sp1 Control Unit,Sinamics Gh150 V4.7 (control Unit),Sinamics Gh150 V4.8 (control Unit),Sinamics Gl150 V4.7 (control Unit),Sinamics Gl150 V4.8 (control Unit),Sinamics Gm150 V4.7 (control Unit),Sinamics Gm150 V4.8 (control Unit),Sinamics S120 V4.6 Control Unit (incl. Siplus Variants),Sinamics S120 V4.7 Control Unit (incl. Siplus Variants),Sinamics S120 V4.7 Sp1 Control Unit (incl. Siplus Variants),Sinamics S120 V4.8 Control Unit (incl. Siplus Variants),Sinamics S120 V5.1 Control Unit (incl. Siplus Variants),Sinamics S120 V5.1 Sp1 Control Unit (incl. Siplus Variants),Sinamics S150 V4.6 Control Unit,Sinamics S150 V4.7 Control Unit,Sinamics S150 V4.7 Sp1 Control Unit,Sinamics S150 V4.8 Control Unit,Sinamics S150 V5.1 Control Unit,Sinamics S150 V5.1 Sp1 Control Unit,Sinamics S210,Sinamics Sl150 V4.7 (control Unit),Sinamics Sl150 V4.8 (control Unit),Sinamics Sm120 V4.7 (control Unit),Sinamics Sm120 V4.8 (control Unit),Sinamics Sm150 V4.8 (control Unit),Siplus Et 200s Im151-8 Pn/dp Cpu,Siplus Et 200s Im151-8f Pn/dp Cpu,Siplus Net Cp 343-1 Advanced,Siplus Net Cp 443-1,Siplus Net Cp 443-1 Advanced,Siplus S7-300 Cpu 314c-2 Pn/dp,Siplus S7-300 Cpu 315-2 Pn/dp,Siplus S7-300 Cpu 315f-2 Pn/dp,Siplus S7-300 Cpu 317-2 Pn/dp,Siplus S7-300 Cpu 317f-2 Pn/dp,Sitop Manager,Sitop Psu8600,Sitop Ups1600 (incl. Siplus Variants),Tim 1531 Irc (incl. Siplus Net Variants)",7.5,HIGH,0.0012000000569969416,false,,false,false,false,,false,false,2019-04-17T13:40:24.000Z,0 CVE-2019-6575,https://securityvulnerability.io/vulnerability/CVE-2019-6575,,"A vulnerability has been identified in SIMATIC CP 443-1 OPC UA (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions < V2.7), SIMATIC HMI Comfort Outdoor Panels 7"" & 15"" (incl. SIPLUS variants) (All versions < V15.1 Upd 4), SIMATIC HMI Comfort Panels 4"" - 22"" (incl. SIPLUS variants) (All versions < V15.1 Upd 4), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15.1 Upd 4), SIMATIC IPC DiagMonitor (All versions < V5.1.3), SIMATIC NET PC Software V13 (All versions), SIMATIC NET PC Software V14 (All versions < V14 SP1 Update 14), SIMATIC NET PC Software V15 (All versions), SIMATIC RF188C (All versions < V1.1.0), SIMATIC RF600R family (All versions < V3.2.1), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions >= V2.5 < V2.6.1), SIMATIC S7-1500 Software Controller (All versions between V2.5 (including) and V2.7 (excluding)), SIMATIC WinCC OA (All versions < V3.15 P018), SIMATIC WinCC Runtime Advanced (All versions < V15.1 Upd 4), SINEC NMS (All versions < V1.0 SP1), SINEMA Server (All versions < V14 SP2), SINUMERIK OPC UA Server (All versions < V2.1), TeleControl Server Basic (All versions < V3.1.1). Specially crafted network packets sent to affected devices on port 4840/tcp could allow an unauthenticated remote attacker to cause a denial of service condition of the OPC communication or crash the device. The security vulnerability could be exploited by an attacker with network access to the affected systems. Successful exploitation requires no system privileges and no user interaction. An attacker could use the vulnerability to compromise availability of the OPC communication.",Siemens,"Simatic Cp 443-1 Opc Ua,Simatic Et 200sp Open Controller Cpu 1515sp Pc2 (incl. Siplus Variants),Simatic Hmi Comfort Outdoor Panels 7"" & 15"" (incl. Siplus Variants),Simatic Hmi Comfort Panels 4"" - 22"" (incl. Siplus Variants),Simatic Hmi Ktp Mobile Panels Ktp400f, Ktp700, Ktp700f, Ktp900 And Ktp900f,Simatic Ipc Diagmonitor,Simatic Net Pc Software V13,Simatic Net Pc Software V14,Simatic Net Pc Software V15,Simatic Rf188c,Simatic Rf600r Family,Simatic S7-1500 Cpu Family (incl. Related Et200 Cpus And Siplus Variants),Simatic S7-1500 Software Controller,Simatic Wincc Oa,Simatic Wincc Runtime Advanced,Sinec Nms,Sinema Server,Sinumerik Opc Ua Server,Telecontrol Server Basic",7.5,HIGH,0.0017900000093504786,false,,false,false,false,,false,false,2019-04-17T13:40:24.000Z,0 CVE-2018-13814,https://securityvulnerability.io/vulnerability/CVE-2018-13814,,"A vulnerability has been identified in SIMATIC HMI Comfort Panels 4"" - 22"" (All versions < V14), SIMATIC HMI Comfort Outdoor Panels 7"" & 15"" (All versions < V14), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V14), SIMATIC WinCC Runtime Advanced (All versions < V14), SIMATIC WinCC Runtime Professional (All versions < V14), SIMATIC WinCC (TIA Portal) (All versions < V14), SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel) (All versions). The integrated web server (port 80/tcp and port 443/tcp) of the affected devices could allow an attacker to inject HTTP headers. An attacker must trick a valid user who is authenticated to the device into clicking on a malicious link to exploit the vulnerability. At the time of advisory publication no public exploitation of this security vulnerability was known.",Siemens,"Simatic Hmi Comfort Panels 4"" - 22"", Simatic Hmi Comfort Outdoor Panels 7"" & 15"", Simatic Hmi Ktp Mobile Panels Ktp400f, Ktp700, Ktp700f, Ktp900 Und Ktp900f, Simatic Wincc Runtime Advanced, Simatic Wincc Runtime Professional, Simatic Wincc (tia Portal), Simatic Hmi Classic Devices (tp/mp/op/mp Mobile Panel)",8.8,HIGH,0.0020800000056624413,false,,false,false,false,,false,false,2018-12-13T16:00:00.000Z,0 CVE-2018-13813,https://securityvulnerability.io/vulnerability/CVE-2018-13813,,"A vulnerability has been identified in SIMATIC HMI Comfort Panels 4"" - 22"" (All versions < V15 Update 4), SIMATIC HMI Comfort Outdoor Panels 7"" & 15"" (All versions < V15 Update 4), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15 Update 4), SIMATIC WinCC Runtime Advanced (All versions < V15 Update 4), SIMATIC WinCC Runtime Professional (All versions < V15 Update 4), SIMATIC WinCC (TIA Portal) (All versions < V15 Update 4), SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel) (All versions). The webserver of affected HMI devices may allow URL redirections to untrusted websites. An attacker must trick a valid user who is authenticated to the device into clicking on a malicious link to exploit the vulnerability. At the time of advisory publication no public exploitation of this security vulnerability was known.",Siemens,"Simatic Hmi Comfort Panels 4"" - 22"", Simatic Hmi Comfort Outdoor Panels 7"" & 15"", Simatic Hmi Ktp Mobile Panels Ktp400f, Ktp700, Ktp700f, Ktp900 Und Ktp900f, Simatic Wincc Runtime Advanced, Simatic Wincc Runtime Professional, Simatic Wincc (tia Portal), Simatic Hmi Classic Devices (tp/mp/op/mp Mobile Panel)",8.1,HIGH,0.0015800000401213765,false,,false,false,false,,false,false,2018-12-13T16:00:00.000Z,0 CVE-2018-13812,https://securityvulnerability.io/vulnerability/CVE-2018-13812,,"A vulnerability has been identified in SIMATIC HMI Comfort Panels 4"" - 22"" (All versions < V15 Update 4), SIMATIC HMI Comfort Outdoor Panels 7"" & 15"" (All versions < V15 Update 4), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15 Update 4), SIMATIC WinCC Runtime Advanced (All versions < V15 Update 4), SIMATIC WinCC Runtime Professional (All versions < V15 Update 4), SIMATIC WinCC (TIA Portal) (All versions < V15 Update 4), SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel) (All versions). A directory traversal vulnerability could allow to download arbitrary files from the device. The security vulnerability could be exploited by an attacker with network access to the integrated web server. No user interaction and no authentication is required to exploit the vulnerability. The vulnerability impacts the confidentiality of the device. At the time of advisory publication no public exploitation of this security vulnerability was known.",Siemens,"Simatic Hmi Comfort Panels 4"" - 22"", Simatic Hmi Comfort Outdoor Panels 7"" & 15"", Simatic Hmi Ktp Mobile Panels Ktp400f, Ktp700, Ktp700f, Ktp900 Und Ktp900f, Simatic Wincc Runtime Advanced, Simatic Wincc Runtime Professional, Simatic Wincc (tia Portal), Simatic Hmi Classic Devices (tp/mp/op/mp Mobile Panel)",7.5,HIGH,0.0017500000540167093,false,,false,false,false,,false,false,2018-12-13T16:00:00.000Z,0