cve,link,title,description,vendor,products,score,severity,epss,cisa,cisa_published,article,ransomware,exploited,poc,trended,trended_no_1,published,trended_score CVE-2021-27386,https://securityvulnerability.io/vulnerability/CVE-2021-27386,,"A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\"" & 15\"" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\"" & 15\"" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI Comfort Panels V15 4\"" - 22\"" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\"" - 22\"" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (All versions < V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (All versions < V16 Update 4), SINAMICS GH150 (All versions), SINAMICS GL150 (with option X30) (All versions), SINAMICS GM150 (with option X30) (All versions), SINAMICS SH150 (All versions), SINAMICS SL150 (All versions), SINAMICS SM120 (All versions), SINAMICS SM150 (All versions), SINAMICS SM150i (All versions). SmartVNC has a heap allocation leak vulnerability in the device layout handler on client side, which could result in a Denial-of-Service condition.",Siemens,"Simatic Hmi Comfort Outdoor Panels V15 7\"" & 15\"" (incl. Siplus Variants),Simatic Hmi Comfort Outdoor Panels V16 7\"" & 15\"" (incl. Siplus Variants),Simatic Hmi Comfort Panels V15 4\"" - 22\"" (incl. Siplus Variants),Simatic Hmi Comfort Panels V16 4\"" - 22\"" (incl. Siplus Variants),Simatic Hmi Ktp Mobile Panels V15 Ktp400f, Ktp700, Ktp700f, Ktp900 And Ktp900f,Simatic Hmi Ktp Mobile Panels V16 Ktp400f, Ktp700, Ktp700f, Ktp900 And Ktp900f,Simatic Wincc Runtime Advanced V15,Simatic Wincc Runtime Advanced V16,Sinamics Gh150,Sinamics Gl150 (with Option X30),Sinamics Gm150 (with Option X30),Sinamics Sh150,Sinamics Sl150,Sinamics Sm120,Sinamics Sm150,Sinamics Sm150i",7.5,HIGH,0.004809999838471413,false,,false,false,false,,false,false,2021-05-12T13:18:23.000Z,0 CVE-2021-27385,https://securityvulnerability.io/vulnerability/CVE-2021-27385,,"A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\"" & 15\"" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\"" & 15\"" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI Comfort Panels V15 4\"" - 22\"" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\"" - 22\"" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (All versions < V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (All versions < V16 Update 4), SINAMICS GH150 (All versions), SINAMICS GL150 (with option X30) (All versions), SINAMICS GM150 (with option X30) (All versions), SINAMICS SH150 (All versions), SINAMICS SL150 (All versions), SINAMICS SM120 (All versions), SINAMICS SM150 (All versions), SINAMICS SM150i (All versions). A remote attacker could send specially crafted packets to SmartVNC device layout handler on client side, which could influence the amount of resources consumed and result in a Denial-of-Service (infinite loop) condition.",Siemens,"Simatic Hmi Comfort Outdoor Panels V15 7\"" & 15\"" (incl. Siplus Variants),Simatic Hmi Comfort Outdoor Panels V16 7\"" & 15\"" (incl. Siplus Variants),Simatic Hmi Comfort Panels V15 4\"" - 22\"" (incl. Siplus Variants),Simatic Hmi Comfort Panels V16 4\"" - 22\"" (incl. Siplus Variants),Simatic Hmi Ktp Mobile Panels V15 Ktp400f, Ktp700, Ktp700f, Ktp900 And Ktp900f,Simatic Hmi Ktp Mobile Panels V16 Ktp400f, Ktp700, Ktp700f, Ktp900 And Ktp900f,Simatic Wincc Runtime Advanced V15,Simatic Wincc Runtime Advanced V16,Sinamics Gh150,Sinamics Gl150 (with Option X30),Sinamics Gm150 (with Option X30),Sinamics Sh150,Sinamics Sl150,Sinamics Sm120,Sinamics Sm150,Sinamics Sm150i",7.5,HIGH,0.0029299999587237835,false,,false,false,false,,false,false,2021-05-12T13:18:23.000Z,0 CVE-2021-27384,https://securityvulnerability.io/vulnerability/CVE-2021-27384,,"A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\"" & 15\"" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\"" & 15\"" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI Comfort Panels V15 4\"" - 22\"" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\"" - 22\"" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (All versions < V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (All versions < V16 Update 4), SINAMICS GH150 (All versions), SINAMICS GL150 (with option X30) (All versions), SINAMICS GM150 (with option X30) (All versions), SINAMICS SH150 (All versions), SINAMICS SL150 (All versions), SINAMICS SM120 (All versions), SINAMICS SM150 (All versions), SINAMICS SM150i (All versions). SmartVNC has an out-of-bounds memory access vulnerability in the device layout handler, represented by a binary data stream on client side, which can potentially result in code execution.",Siemens,"Simatic Hmi Comfort Outdoor Panels V15 7\"" & 15\"" (incl. Siplus Variants),Simatic Hmi Comfort Outdoor Panels V16 7\"" & 15\"" (incl. Siplus Variants),Simatic Hmi Comfort Panels V15 4\"" - 22\"" (incl. Siplus Variants),Simatic Hmi Comfort Panels V16 4\"" - 22\"" (incl. Siplus Variants),Simatic Hmi Ktp Mobile Panels V15 Ktp400f, Ktp700, Ktp700f, Ktp900 And Ktp900f,Simatic Hmi Ktp Mobile Panels V16 Ktp400f, Ktp700, Ktp700f, Ktp900 And Ktp900f,Simatic Wincc Runtime Advanced V15,Simatic Wincc Runtime Advanced V16,Sinamics Gh150,Sinamics Gl150 (with Option X30),Sinamics Gm150 (with Option X30),Sinamics Sh150,Sinamics Sl150,Sinamics Sm120,Sinamics Sm150,Sinamics Sm150i",9.8,CRITICAL,0.005330000072717667,false,,false,false,false,,false,false,2021-05-12T13:18:22.000Z,0 CVE-2021-25660,https://securityvulnerability.io/vulnerability/CVE-2021-25660,,"A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\"" & 15\"" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\"" & 15\"" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI Comfort Panels V15 4\"" - 22\"" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\"" - 22\"" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (All versions < V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (All versions < V16 Update 4). SmartVNC has an out-of-bounds memory access vulnerability that could be triggered on the server side when sending data from the client, which could result in a Denial-of-Service condition.",Siemens,"Simatic Hmi Comfort Outdoor Panels V15 7\"" & 15\"" (incl. Siplus Variants),Simatic Hmi Comfort Outdoor Panels V16 7\"" & 15\"" (incl. Siplus Variants),Simatic Hmi Comfort Panels V15 4\"" - 22\"" (incl. Siplus Variants),Simatic Hmi Comfort Panels V16 4\"" - 22\"" (incl. Siplus Variants),Simatic Hmi Ktp Mobile Panels V15 Ktp400f, Ktp700, Ktp700f, Ktp900 And Ktp900f,Simatic Hmi Ktp Mobile Panels V16 Ktp400f, Ktp700, Ktp700f, Ktp900 And Ktp900f,Simatic Wincc Runtime Advanced V15,Simatic Wincc Runtime Advanced V16",7.5,HIGH,0.0014700000174343586,false,,false,false,false,,false,false,2021-05-12T13:18:22.000Z,0 CVE-2021-27383,https://securityvulnerability.io/vulnerability/CVE-2021-27383,,"A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\"" & 15\"" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\"" & 15\"" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI Comfort Panels V15 4\"" - 22\"" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\"" - 22\"" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (All versions < V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (All versions < V16 Update 4), SINAMICS GH150 (All versions), SINAMICS GL150 (with option X30) (All versions), SINAMICS GM150 (with option X30) (All versions), SINAMICS SH150 (All versions), SINAMICS SL150 (All versions), SINAMICS SM120 (All versions), SINAMICS SM150 (All versions), SINAMICS SM150i (All versions). SmartVNC has a heap allocation leak vulnerability in the server Tight encoder, which could result in a Denial-of-Service condition.",Siemens,"Simatic Hmi Comfort Outdoor Panels V15 7\"" & 15\"" (incl. Siplus Variants),Simatic Hmi Comfort Outdoor Panels V16 7\"" & 15\"" (incl. Siplus Variants),Simatic Hmi Comfort Panels V15 4\"" - 22\"" (incl. Siplus Variants),Simatic Hmi Comfort Panels V16 4\"" - 22\"" (incl. Siplus Variants),Simatic Hmi Ktp Mobile Panels V15 Ktp400f, Ktp700, Ktp700f, Ktp900 And Ktp900f,Simatic Hmi Ktp Mobile Panels V16 Ktp400f, Ktp700, Ktp700f, Ktp900 And Ktp900f,Simatic Wincc Runtime Advanced V15,Simatic Wincc Runtime Advanced V16,Sinamics Gh150,Sinamics Gl150 (with Option X30),Sinamics Gm150 (with Option X30),Sinamics Sh150,Sinamics Sl150,Sinamics Sm120,Sinamics Sm150,Sinamics Sm150i",7.5,HIGH,0.0016599999507889152,false,,false,false,false,,false,false,2021-05-12T13:18:22.000Z,0 CVE-2021-25661,https://securityvulnerability.io/vulnerability/CVE-2021-25661,,"A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\"" & 15\"" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\"" & 15\"" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI Comfort Panels V15 4\"" - 22\"" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\"" - 22\"" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (All versions < V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (All versions < V16 Update 4). SmartVNC has an out-of-bounds memory access vulnerability that could be triggered on the client side when sending data from the server, which could result in a Denial-of-Service condition.",Siemens,"Simatic Hmi Comfort Outdoor Panels V15 7\"" & 15\"" (incl. Siplus Variants),Simatic Hmi Comfort Outdoor Panels V16 7\"" & 15\"" (incl. Siplus Variants),Simatic Hmi Comfort Panels V15 4\"" - 22\"" (incl. Siplus Variants),Simatic Hmi Comfort Panels V16 4\"" - 22\"" (incl. Siplus Variants),Simatic Hmi Ktp Mobile Panels V15 Ktp400f, Ktp700, Ktp700f, Ktp900 And Ktp900f,Simatic Hmi Ktp Mobile Panels V16 Ktp400f, Ktp700, Ktp700f, Ktp900 And Ktp900f,Simatic Wincc Runtime Advanced V15,Simatic Wincc Runtime Advanced V16",7.5,HIGH,0.0014600000577047467,false,,false,false,false,,false,false,2021-05-12T13:18:22.000Z,0 CVE-2021-25662,https://securityvulnerability.io/vulnerability/CVE-2021-25662,,"A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\"" & 15\"" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\"" & 15\"" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI Comfort Panels V15 4\"" - 22\"" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\"" - 22\"" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (All versions < V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (All versions < V16 Update 4). SmartVNC client fails to handle an exception properly if the program execution process is modified after sending a packet from the server, which could result in a Denial-of-Service condition.",Siemens,"Simatic Hmi Comfort Outdoor Panels V15 7\"" & 15\"" (incl. Siplus Variants),Simatic Hmi Comfort Outdoor Panels V16 7\"" & 15\"" (incl. Siplus Variants),Simatic Hmi Comfort Panels V15 4\"" - 22\"" (incl. Siplus Variants),Simatic Hmi Comfort Panels V16 4\"" - 22\"" (incl. Siplus Variants),Simatic Hmi Ktp Mobile Panels V15 Ktp400f, Ktp700, Ktp700f, Ktp900 And Ktp900f,Simatic Hmi Ktp Mobile Panels V16 Ktp400f, Ktp700, Ktp700f, Ktp900 And Ktp900f,Simatic Wincc Runtime Advanced V15,Simatic Wincc Runtime Advanced V16",7.5,HIGH,0.008379999548196793,false,,false,false,false,,false,false,2021-05-12T13:18:22.000Z,0 CVE-2020-7580,https://securityvulnerability.io/vulnerability/CVE-2020-7580,,"A vulnerability has been identified in SIMATIC Automation Tool (All versions < V4 SP2), SIMATIC NET PC Software V14 (All versions < V14 SP1 Update 14), SIMATIC NET PC Software V15 (All versions), SIMATIC NET PC Software V16 (All versions < V16 Upd3), SIMATIC PCS neo (All versions < V3.0 SP1), SIMATIC ProSave (All versions < V17), SIMATIC S7-1500 Software Controller (All versions < V21.8), SIMATIC STEP 7 (TIA Portal) V13 (All versions < V13 SP2 Update 4), SIMATIC STEP 7 (TIA Portal) V14 (All versions < V14 SP1 Update 10), SIMATIC STEP 7 (TIA Portal) V15 (All versions < V15.1 Update 5), SIMATIC STEP 7 (TIA Portal) V16 (All versions < V16 Update 2), SIMATIC STEP 7 V5 (All versions < V5.6 SP2 HF3), SIMATIC WinCC OA V3.16 (All versions < V3.16 P018), SIMATIC WinCC OA V3.17 (All versions < V3.17 P003), SIMATIC WinCC Runtime Advanced (All versions < V16 Update 2), SIMATIC WinCC Runtime Professional V13 (All versions < V13 SP2 Update 4), SIMATIC WinCC Runtime Professional V14 (All versions < V14 SP1 Update 10), SIMATIC WinCC Runtime Professional V15 (All versions < V15.1 Update 5), SIMATIC WinCC Runtime Professional V16 (All versions < V16 Update 2), SIMATIC WinCC V7.4 (All versions < V7.4 SP1 Update 14), SIMATIC WinCC V7.5 (All versions < V7.5 SP1 Update 3), SINAMICS STARTER (All Versions < V5.4 HF2), SINAMICS Startdrive (All Versions < V16 Update 3), SINEC NMS (All versions < V1.0 SP2), SINEMA Server (All versions < V14 SP3), SINUMERIK ONE virtual (All Versions < V6.14), SINUMERIK Operate (All Versions < V6.14). A common component used by the affected applications regularly calls a helper binary with SYSTEM privileges while the call path is not quoted. This could allow a local attacker to execute arbitrary code with SYTEM privileges.",Siemens,"Simatic Automation Tool,Simatic Net Pc Software V14,Simatic Net Pc Software V15,Simatic Net Pc Software V16,Simatic Pcs Neo,Simatic Prosave,Simatic S7-1500 Software Controller,Simatic Step 7 (tia Portal) V13,Simatic Step 7 (tia Portal) V14,Simatic Step 7 (tia Portal) V15,Simatic Step 7 (tia Portal) V16,Simatic Step 7 V5,Simatic Wincc Oa V3.16,Simatic Wincc Oa V3.17,Simatic Wincc Runtime Advanced,Simatic Wincc Runtime Professional V13,Simatic Wincc Runtime Professional V14,Simatic Wincc Runtime Professional V15,Simatic Wincc Runtime Professional V16,Simatic Wincc V7.4,Simatic Wincc V7.5,Sinamics Starter,Sinamics Startdrive,Sinec Nms,Sinema Server,Sinumerik One Virtual,Sinumerik Operate",6.7,MEDIUM,0.0004600000102072954,false,,false,false,false,,false,false,2020-06-10T00:00:00.000Z,0 CVE-2019-10929,https://securityvulnerability.io/vulnerability/CVE-2019-10929,,"A vulnerability has been identified in SIMATIC CP 1626 (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants) (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions < V20.8), SIMATIC HMI Panel (incl. SIPLUS variants) (All versions), SIMATIC NET PC Software V14 (All versions < V14 SP1 Update 14), SIMATIC NET PC Software V15 (All versions), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions < V4.4.0), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions < V2.8.1), SIMATIC S7-1500 Software Controller (All versions < V20.8), SIMATIC S7-PLCSIM Advanced (All versions < V3.0), SIMATIC STEP 7 (TIA Portal) (All versions < V16), SIMATIC WinCC (TIA Portal) (All versions < V16), SIMATIC WinCC OA (All versions < V3.16 P013), SIMATIC WinCC Runtime Advanced (All versions < V16), SIMATIC WinCC Runtime Professional (All versions < V16), TIM 1531 IRC (incl. SIPLUS NET variants) (All versions < V2.1). Affected devices contain a message protection bypass vulnerability due to certain properties in the calculation used for integrity protection. This could allow an attacker in a Man-in-the-Middle position to modify network traffic sent on port 102/tcp to the affected devices.",Siemens,"Simatic Cp 1626,Simatic Et 200sp Open Controller Cpu 1515sp Pc (incl. Siplus Variants),Simatic Et 200sp Open Controller Cpu 1515sp Pc2 (incl. Siplus Variants),Simatic Hmi Panel (incl. Siplus Variants),Simatic Net Pc Software V14,Simatic Net Pc Software V15,Simatic S7-1200 Cpu Family (incl. Siplus Variants),Simatic S7-1500 Cpu Family (incl. Related Et200 Cpus And Siplus Variants),Simatic S7-1500 Software Controller,Simatic S7-plcsim Advanced,Simatic Step 7 (tia Portal),Simatic Wincc (tia Portal),Simatic Wincc Oa,Simatic Wincc Runtime Advanced,Simatic Wincc Runtime Professional,Tim 1531 Irc (incl. Siplus Net Variants)",5.9,MEDIUM,0.002360000042244792,false,,false,false,false,,false,false,2019-08-13T18:55:57.000Z,0 CVE-2019-6575,https://securityvulnerability.io/vulnerability/CVE-2019-6575,,"A vulnerability has been identified in SIMATIC CP 443-1 OPC UA (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions < V2.7), SIMATIC HMI Comfort Outdoor Panels 7"" & 15"" (incl. SIPLUS variants) (All versions < V15.1 Upd 4), SIMATIC HMI Comfort Panels 4"" - 22"" (incl. SIPLUS variants) (All versions < V15.1 Upd 4), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15.1 Upd 4), SIMATIC IPC DiagMonitor (All versions < V5.1.3), SIMATIC NET PC Software V13 (All versions), SIMATIC NET PC Software V14 (All versions < V14 SP1 Update 14), SIMATIC NET PC Software V15 (All versions), SIMATIC RF188C (All versions < V1.1.0), SIMATIC RF600R family (All versions < V3.2.1), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions >= V2.5 < V2.6.1), SIMATIC S7-1500 Software Controller (All versions between V2.5 (including) and V2.7 (excluding)), SIMATIC WinCC OA (All versions < V3.15 P018), SIMATIC WinCC Runtime Advanced (All versions < V15.1 Upd 4), SINEC NMS (All versions < V1.0 SP1), SINEMA Server (All versions < V14 SP2), SINUMERIK OPC UA Server (All versions < V2.1), TeleControl Server Basic (All versions < V3.1.1). Specially crafted network packets sent to affected devices on port 4840/tcp could allow an unauthenticated remote attacker to cause a denial of service condition of the OPC communication or crash the device. The security vulnerability could be exploited by an attacker with network access to the affected systems. Successful exploitation requires no system privileges and no user interaction. An attacker could use the vulnerability to compromise availability of the OPC communication.",Siemens,"Simatic Cp 443-1 Opc Ua,Simatic Et 200sp Open Controller Cpu 1515sp Pc2 (incl. Siplus Variants),Simatic Hmi Comfort Outdoor Panels 7"" & 15"" (incl. Siplus Variants),Simatic Hmi Comfort Panels 4"" - 22"" (incl. Siplus Variants),Simatic Hmi Ktp Mobile Panels Ktp400f, Ktp700, Ktp700f, Ktp900 And Ktp900f,Simatic Ipc Diagmonitor,Simatic Net Pc Software V13,Simatic Net Pc Software V14,Simatic Net Pc Software V15,Simatic Rf188c,Simatic Rf600r Family,Simatic S7-1500 Cpu Family (incl. Related Et200 Cpus And Siplus Variants),Simatic S7-1500 Software Controller,Simatic Wincc Oa,Simatic Wincc Runtime Advanced,Sinec Nms,Sinema Server,Sinumerik Opc Ua Server,Telecontrol Server Basic",7.5,HIGH,0.0017900000093504786,false,,false,false,false,,false,false,2019-04-17T13:40:24.000Z,0