cve,link,title,description,vendor,products,score,severity,epss,cisa,cisa_published,article,ransomware,exploited,poc,trended,trended_no_1,published,trended_score CVE-2024-49849,https://securityvulnerability.io/vulnerability/CVE-2024-49849,"{""Vulnerability in Siemens Products Could Allow Arbitrary Code Execution""}","A vulnerability has been identified across multiple versions and products within Siemens' SIMATIC and TIA Portal lines. The flaw involves inadequate sanitization of user-controllable input when parsing log files, potentially allowing an attacker to exploit this weakness. This exploitation may lead to type confusion and the execution of arbitrary code within the affected applications, compromising operational integrity and security.",Siemens,"Simatic S7-plcsim V16,Simatic S7-plcsim V17,Simatic Step 7 Safety V16,Simatic Step 7 Safety V17,Simatic Step 7 Safety V18,Simatic Step 7 Safety V19,Simatic Step 7 V16,Simatic Step 7 V17,Simatic Step 7 V18,Simatic Step 7 V19,Simatic Wincc Unified V16,Simatic Wincc Unified V17,Simatic Wincc Unified V18,Simatic Wincc Unified V19,Simatic Wincc V16,Simatic Wincc V17,Simatic Wincc V18,Simatic Wincc V19,Simocode Es V16,Simocode Es V17,Simocode Es V18,Simocode Es V19,Simotion Scout Tia V5.4 Sp1,Simotion Scout Tia V5.4 Sp3,Simotion Scout Tia V5.5 Sp1,Simotion Scout Tia V5.6 Sp1,Sinamics Startdrive V16,Sinamics Startdrive V17,Sinamics Startdrive V18,Sinamics Startdrive V19,Sirius Safety Es V17 (tia Portal),Sirius Safety Es V18 (tia Portal),Sirius Safety Es V19 (tia Portal),Sirius Soft Starter Es V17 (tia Portal),Sirius Soft Starter Es V18 (tia Portal),Sirius Soft Starter Es V19 (tia Portal),Tia Portal Cloud V16,Tia Portal Cloud V17,Tia Portal Cloud V18,Tia Portal Cloud V19",7.8,HIGH,0.0005300000193528831,false,,false,false,false,,false,false,2024-12-10T13:53:56.043Z,0 CVE-2023-32736,https://securityvulnerability.io/vulnerability/CVE-2023-32736,"{""Vulnerability in Siemens Products Could Allow Arbitrary Code Execution""}","A vulnerability exists in various Siemens automation products that fail to adequately sanitize user-controllable input, especially when processing user settings. This flaw could facilitate type confusion, potentially allowing an attacker to execute arbitrary code within the affected application. Affected software includes SIMATIC S7-PLCSIM, STEP 7, WinCC, and other associated tools, and users are advised to review the latest updates and apply necessary patches to mitigate this risk. For detailed information, refer to the provided reference.",Siemens,"Simatic S7-plcsim V16,Simatic S7-plcsim V17,Simatic Step 7 Safety V16,Simatic Step 7 Safety V17,Simatic Step 7 Safety V18,Simatic Step 7 V16,Simatic Step 7 V17,Simatic Step 7 V18,Simatic Wincc Unified V16,Simatic Wincc Unified V17,Simatic Wincc Unified V18,Simatic Wincc V16,Simatic Wincc V17,Simatic Wincc V18,Simocode Es V16,Simocode Es V17,Simocode Es V18,Simotion Scout Tia V5.4 Sp1,Simotion Scout Tia V5.4 Sp3,Simotion Scout Tia V5.5 Sp1,Sinamics Startdrive V16,Sinamics Startdrive V17,Sinamics Startdrive V18,Sirius Safety Es V17,Sirius Safety Es V18,Sirius Soft Starter Es V17,Sirius Soft Starter Es V18,Tia Portal Cloud V16,Tia Portal Cloud V17,Tia Portal Cloud V18",7.3,HIGH,0.0004299999854993075,false,,false,false,false,,false,false,2024-11-12T12:49:22.651Z,0 CVE-2023-32735,https://securityvulnerability.io/vulnerability/CVE-2023-32735,"{""Siemens: Multiple Products Affected by Deserialization Vulnerability"",""Siemens: Simatic Safety and Motion Control"",""Siemens: Sinamics Drive Technologies"",""Siemens: Simotion Safety"",""Siemens: TIA Portal Cloud""}","A vulnerability exists in various Siemens products, including SIMATIC STEP 7, SIMATIC WinCC, and other related applications, that fails to properly restrict .NET BinaryFormatter during the deserialization of hardware configuration profiles. This imperfection may lead to type confusion, enabling an attacker to execute arbitrary code within affected applications. This could result in unauthorized actions or data manipulation, posing a significant risk to system integrity and operations.",Siemens,"Simatic Step 7 Safety V16,Simatic Step 7 Safety V17,Simatic Step 7 Safety V18,Simatic Step 7 V16,Simatic Step 7 V17,Simatic Step 7 V18,Simatic Wincc Unified V16,Simatic Wincc Unified V17,Simatic Wincc Unified V18,Simatic Wincc V16,Simatic Wincc V17,Simatic Wincc V18,Simocode Es V16,Simocode Es V17,Simocode Es V18,Simotion Scout Tia V5.4 Sp1,Simotion Scout Tia V5.4 Sp3,Simotion Scout Tia V5.5 Sp1,Sinamics Startdrive V16,Sinamics Startdrive V17,Sinamics Startdrive V18,Sirius Safety Es V17,Sirius Safety Es V18,Sirius Soft Starter Es V17,Sirius Soft Starter Es V18,Soft Starter Es V16,Tia Portal Cloud V3.0",6.5,MEDIUM,0.0004299999854993075,false,,false,false,false,,false,false,2024-07-09T12:04:26.871Z,0 CVE-2023-46280,https://securityvulnerability.io/vulnerability/CVE-2023-46280,Out of Bounds Read Vulnerability in SIMATIC and TIA Portal Products by Siemens,"An out of bounds read vulnerability has been identified in multiple Siemens products, including the SIMATIC and TIA Portal series. This flaw can potentially lead to the crashing of the Windows kernel, resulting in a Blue Screen of Death (BSOD) error. Attackers could exploit this vulnerability to destabilize systems, impacting operational efficiency and safety within industrial environments. It is crucial for users of these products to be aware of this vulnerability and to implement necessary mitigations as outlined by Siemens.",Siemens,"Security Configuration Tool (sct),Simatic Automation Tool,Simatic Batch V9.1,Simatic Net Pc Software V16,Simatic Net Pc Software V17,Simatic Net Pc Software V18,Simatic Net Pc Software V19,Simatic Pcs 7 V9.1,Simatic Pdm V9.2,Simatic Route Control V9.1,Simatic S7-pct,Simatic Step 7 V5,Simatic Wincc Oa V3.17,Simatic Wincc Oa V3.18,Simatic Wincc Oa V3.19,Simatic Wincc Runtime Advanced,Simatic Wincc Runtime Professional V16,Simatic Wincc Runtime Professional V17,Simatic Wincc Runtime Professional V18,Simatic Wincc Runtime Professional V19,Simatic Wincc V7.4,Simatic Wincc V7.5,Simatic Wincc V8.0,Sinamics Startdrive,Sinec Nms,Sinumerik One Virtual,Sinumerik Plc Programming Tool,Tia Portal Cloud Connector,Totally Integrated Automation Portal (tia Portal) V15.1,Totally Integrated Automation Portal (tia Portal) V16,Totally Integrated Automation Portal (tia Portal) V17,Totally Integrated Automation Portal (tia Portal) V18,Totally Integrated Automation Portal (tia Portal) V19",6.5,MEDIUM,0.00044999999227002263,false,,false,false,false,,false,false,2024-05-14T10:01:52.069Z,0 CVE-2023-28831,https://securityvulnerability.io/vulnerability/CVE-2023-28831,Integer Overflow Issue in Siemens OPC UA Implementations,"The OPC UA implementations in Siemens products harbor an integer overflow vulnerability that can lead to an infinite loop during the certificate validation process. This condition could be exploited by an unauthenticated remote attacker utilizing a specially crafted certificate, resulting in a denial of service that impacts application availability and reliability.",Siemens,"Simatic Braumat,Simatic Cloud Connect 7 Cc712,Simatic Cloud Connect 7 Cc716,Simatic Comfort/mobile Rt,Simatic Drive Controller Cpu 1504d Tf,Simatic Drive Controller Cpu 1507d Tf,Simatic Et 200sp Open Controller Cpu 1515sp Pc2 (incl. Siplus Variants),Simatic Ipc Diagmonitor,Simatic Net Pc Software V14,Simatic Net Pc Software V16,Simatic Net Pc Software V17,Simatic Net Pc Software V18,Simatic Pcs 7 V9.1,Simatic Pcs Neo V4.0,Simatic S7-1500 Cpu 1510sp F-1 Pn,Simatic S7-1500 Cpu 1510sp-1 Pn,Simatic S7-1500 Cpu 1511-1 Pn,Simatic S7-1500 Cpu 1511c-1 Pn,Simatic S7-1500 Cpu 1511f-1 Pn,Simatic S7-1500 Cpu 1511t-1 Pn,Simatic S7-1500 Cpu 1511tf-1 Pn,Simatic S7-1500 Cpu 1512c-1 Pn,Simatic S7-1500 Cpu 1512sp F-1 Pn,Simatic S7-1500 Cpu 1512sp-1 Pn,Simatic S7-1500 Cpu 1513-1 Pn,Simatic S7-1500 Cpu 1513f-1 Pn,Simatic S7-1500 Cpu 1514sp F-2 Pn,Simatic S7-1500 Cpu 1514sp-2 Pn,Simatic S7-1500 Cpu 1514spt F-2 Pn,Simatic S7-1500 Cpu 1514spt-2 Pn,Simatic S7-1500 Cpu 1515-2 Pn,Simatic S7-1500 Cpu 1515f-2 Pn,Simatic S7-1500 Cpu 1515t-2 Pn,Simatic S7-1500 Cpu 1515tf-2 Pn,Simatic S7-1500 Cpu 1516-3 Pn/dp,Simatic S7-1500 Cpu 1516f-3 Pn/dp,Simatic S7-1500 Cpu 1516t-3 Pn/dp,Simatic S7-1500 Cpu 1516tf-3 Pn/dp,Simatic S7-1500 Cpu 1517-3 Pn/dp,Simatic S7-1500 Cpu 1517f-3 Pn/dp,Simatic S7-1500 Cpu 1517t-3 Pn/dp,Simatic S7-1500 Cpu 1517tf-3 Pn/dp,Simatic S7-1500 Cpu 1518-4 Pn/dp,Simatic S7-1500 Cpu 1518-4 Pn/dp Mfp,Simatic S7-1500 Cpu 1518f-4 Pn/dp,Simatic S7-1500 Cpu 1518f-4 Pn/dp Mfp,Simatic S7-1500 Cpu 1518t-4 Pn/dp,Simatic S7-1500 Cpu 1518tf-4 Pn/dp,Simatic S7-1500 Cpu S7-1518-4 Pn/dp Odk,Simatic S7-1500 Cpu S7-1518f-4 Pn/dp Odk,Simatic S7-1500 Et 200pro: Cpu 1513pro F-2 Pn,Simatic S7-1500 Et 200pro: Cpu 1513pro-2 Pn,Simatic S7-1500 Et 200pro: Cpu 1516pro F-2 Pn,Simatic S7-1500 Et 200pro: Cpu 1516pro-2 Pn,Simatic S7-1500 Software Controller V2,Simatic S7-1500 Software Controller V3,Simatic S7-plcsim Advanced,Simatic Sistar,Simatic Wincc Oa V3.17,Simatic Wincc Oa V3.18,Simatic Wincc Oa V3.19,Simatic Wincc Opc Ua Client,Simatic Wincc Runtime Professional V16,Simatic Wincc Runtime Professional V17,Simatic Wincc Runtime Professional V18,Simatic Wincc Runtime Professional V19,Simatic Wincc Unified Opc Ua Server,Simatic Wincc V7.4,Simatic Wincc V7.5,Simatic Wincc V8.0,Sinumerik Mc,Sinumerik One,Siplus Et 200sp Cpu 1510sp F-1 Pn,Siplus Et 200sp Cpu 1510sp F-1 Pn Rail,Siplus Et 200sp Cpu 1510sp-1 Pn,Siplus Et 200sp Cpu 1510sp-1 Pn Rail,Siplus Et 200sp Cpu 1512sp F-1 Pn,Siplus Et 200sp Cpu 1512sp F-1 Pn Rail,Siplus Et 200sp Cpu 1512sp-1 Pn,Siplus Et 200sp Cpu 1512sp-1 Pn Rail,Siplus S7-1500 Cpu 1511-1 Pn,Siplus S7-1500 Cpu 1511-1 Pn T1 Rail,Siplus S7-1500 Cpu 1511-1 Pn Tx Rail,Siplus S7-1500 Cpu 1511f-1 Pn,Siplus S7-1500 Cpu 1513-1 Pn,Siplus S7-1500 Cpu 1513f-1 Pn,Siplus S7-1500 Cpu 1515f-2 Pn,Siplus S7-1500 Cpu 1515f-2 Pn Rail,Siplus S7-1500 Cpu 1515f-2 Pn T2 Rail,Siplus S7-1500 Cpu 1516-3 Pn/dp,Siplus S7-1500 Cpu 1516-3 Pn/dp Rail,Siplus S7-1500 Cpu 1516-3 Pn/dp Tx Rail,Siplus S7-1500 Cpu 1516f-3 Pn/dp,Siplus S7-1500 Cpu 1516f-3 Pn/dp Rail,Siplus S7-1500 Cpu 1518-4 Pn/dp,Siplus S7-1500 Cpu 1518-4 Pn/dp Mfp,Siplus S7-1500 Cpu 1518f-4 Pn/dp",7.5,HIGH,0.0005300000193528831,false,,false,false,false,,false,false,2023-09-12T10:15:00.000Z,0 CVE-2022-24287,https://securityvulnerability.io/vulnerability/CVE-2022-24287,Vulnerability in Siemens SIMATIC Products Allows Kiosk Mode Escape,"A security flaw in Siemens' SIMATIC products allows an authenticated attacker to bypass the Kiosk Mode due to a missing printer configuration on the host. This vulnerability affects various versions of the SIMATIC PCS 7 and WinCC products, which could potentially lead to unauthorized access and manipulation of the systems. It is critical for users to ensure correct printer configurations to mitigate this risk effectively.",Siemens,"Simatic Pcs 7 V8.2,Simatic Pcs 7 V9.0,Simatic Pcs 7 V9.1,Simatic Wincc Runtime Professional V16 And Earlier,Simatic Wincc Runtime Professional V17,Simatic Wincc V7.3,Simatic Wincc V7.4,Simatic Wincc V7.5",7.8,HIGH,0.0004400000034365803,false,,false,false,false,,false,false,2022-05-20T13:15:00.000Z,0 CVE-2021-40363,https://securityvulnerability.io/vulnerability/CVE-2021-40363,,"A vulnerability has been identified in SIMATIC PCS 7 V8.2 (All versions), SIMATIC PCS 7 V9.0 (All versions), SIMATIC PCS 7 V9.1 (All versions < V9.1 SP1), SIMATIC WinCC V15 and earlier (All versions < V15 SP1 Update 7), SIMATIC WinCC V16 (All versions < V16 Update 5), SIMATIC WinCC V17 (All versions < V17 Update 2), SIMATIC WinCC V17 (All versions <= V17 Update 4), SIMATIC WinCC V7.4 (All versions < V7.4 SP1 Update 19), SIMATIC WinCC V7.5 (All versions < V7.5 SP2 Update 6). The affected component stores the credentials of a local system account in a potentially publicly accessible project file using an outdated cipher algorithm. An attacker may use this to brute force the credentials and take over the system.",Siemens,"Simatic Pcs 7 V8.2,Simatic Pcs 7 V9.0,Simatic Pcs 7 V9.1,Simatic Wincc V15 And Earlier,Simatic Wincc V16,Simatic Wincc V17,Simatic Wincc V7.4,Simatic Wincc V7.5",7.8,HIGH,0.0004400000034365803,false,,false,false,false,,false,false,2022-02-09T15:17:04.000Z,0 CVE-2021-40360,https://securityvulnerability.io/vulnerability/CVE-2021-40360,,"A vulnerability has been identified in SIMATIC PCS 7 V8.2 (All versions), SIMATIC PCS 7 V9.0 (All versions), SIMATIC PCS 7 V9.1 (All versions < V9.1 SP1), SIMATIC WinCC V15 and earlier (All versions < V15 SP1 Update 7), SIMATIC WinCC V16 (All versions < V16 Update 5), SIMATIC WinCC V17 (All versions < V17 Update 2), SIMATIC WinCC V7.4 (All versions < V7.4 SP1 Update 19), SIMATIC WinCC V7.5 (All versions < V7.5 SP2 Update 6). The password hash of a local user account in the remote server could be granted via public API to a user on the affected system. An authenticated attacker could brute force the password hash and use it to login to the server.",Siemens,"Simatic Pcs 7 V8.2,Simatic Pcs 7 V9.0,Simatic Pcs 7 V9.1,Simatic Wincc V15 And Earlier,Simatic Wincc V16,Simatic Wincc V17,Simatic Wincc V7.4,Simatic Wincc V7.5",8.8,HIGH,0.0008800000068731606,false,,false,false,false,,false,false,2022-02-09T15:17:03.000Z,0 CVE-2021-40364,https://securityvulnerability.io/vulnerability/CVE-2021-40364,,"A vulnerability has been identified in SIMATIC PCS 7 V8.2 (All versions), SIMATIC PCS 7 V9.0 (All versions < V9.0 SP3 UC04), SIMATIC PCS 7 V9.1 (All versions < V9.1 SP1), SIMATIC WinCC V15 and earlier (All versions < V15 SP1 Update 7), SIMATIC WinCC V16 (All versions < V16 Update 5), SIMATIC WinCC V17 (All versions < V17 Update 2), SIMATIC WinCC V7.4 (All versions < V7.4 SP1 Update 19), SIMATIC WinCC V7.5 (All versions < V7.5 SP2 Update 5). The affected systems store sensitive information in log files. An attacker with access to the log files could publicly expose the information or reuse it to develop further attacks on the system.",Siemens,"Simatic Pcs 7 V8.2,Simatic Pcs 7 V9.0,Simatic Pcs 7 V9.1,Simatic Wincc V15 And Earlier,Simatic Wincc V16,Simatic Wincc V17,Simatic Wincc V7.4,Simatic Wincc V7.5",5.5,MEDIUM,0.00139999995008111,false,,false,false,false,,false,false,2021-11-09T11:32:06.000Z,0 CVE-2021-40359,https://securityvulnerability.io/vulnerability/CVE-2021-40359,,"A vulnerability has been identified in OpenPCS 7 V8.2 (All versions), OpenPCS 7 V9.0 (All versions < V9.0 Upd4), OpenPCS 7 V9.1 (All versions), SIMATIC BATCH V8.2 (All versions), SIMATIC BATCH V9.0 (All versions), SIMATIC BATCH V9.1 (All versions), SIMATIC NET PC Software V14 (All versions), SIMATIC NET PC Software V15 (All versions), SIMATIC NET PC Software V16 (All versions < V16 Update 6), SIMATIC NET PC Software V17 (All versions < V17 SP1), SIMATIC PCS 7 V8.2 (All versions), SIMATIC PCS 7 V9.0 (All versions < V9.0 SP3 UC04), SIMATIC PCS 7 V9.1 (All versions < V9.1 SP1), SIMATIC Route Control V8.2 (All versions), SIMATIC Route Control V9.0 (All versions), SIMATIC Route Control V9.1 (All versions), SIMATIC WinCC V15 and earlier (All versions < V15 SP1 Update 7), SIMATIC WinCC V16 (All versions < V16 Update 5), SIMATIC WinCC V17 (All versions < V17 Update 2), SIMATIC WinCC V7.4 (All versions < V7.4 SP1 Update 19), SIMATIC WinCC V7.5 (All versions < V7.5 SP2 Update 5). When downloading files, the affected systems do not properly neutralize special elements within the pathname. An attacker could then cause the pathname to resolve to a location outside of the restricted directory on the server and read unexpected critical files.",Siemens,"Openpcs 7 V8.2,Openpcs 7 V9.0,Openpcs 7 V9.1,Simatic Batch V8.2,Simatic Batch V9.0,Simatic Batch V9.1,Simatic Net Pc Software V14,Simatic Net Pc Software V15,Simatic Net Pc Software V16,Simatic Net Pc Software V17,Simatic Pcs 7 V8.2,Simatic Pcs 7 V9.0,Simatic Pcs 7 V9.1,Simatic Route Control V8.2,Simatic Route Control V9.0,Simatic Route Control V9.1,Simatic Wincc V15 And Earlier,Simatic Wincc V16,Simatic Wincc V17,Simatic Wincc V7.4,Simatic Wincc V7.5",7.7,HIGH,0.0021299999207258224,false,,false,false,false,,false,false,2021-11-09T11:32:05.000Z,0 CVE-2021-40358,https://securityvulnerability.io/vulnerability/CVE-2021-40358,,"A vulnerability has been identified in SIMATIC PCS 7 V8.2 (All versions), SIMATIC PCS 7 V9.0 (All versions < V9.0 SP3 UC04), SIMATIC PCS 7 V9.1 (All versions < V9.1 SP1), SIMATIC WinCC V15 and earlier (All versions < V15 SP1 Update 7), SIMATIC WinCC V16 (All versions < V16 Update 5), SIMATIC WinCC V17 (All versions < V17 Update 2), SIMATIC WinCC V7.4 (All versions < V7.4 SP1 Update 19), SIMATIC WinCC V7.5 (All versions < V7.5 SP2 Update 5). Legitimate file operations on the web server of the affected systems do not properly neutralize special elements within the pathname. An attacker could then cause the pathname to resolve to a location outside of the restricted directory on the server and read, write or delete unexpected critical files.",Siemens,"Simatic Pcs 7 V8.2,Simatic Pcs 7 V9.0,Simatic Pcs 7 V9.1,Simatic Wincc V15 And Earlier,Simatic Wincc V16,Simatic Wincc V17,Simatic Wincc V7.4,Simatic Wincc V7.5",9.9,CRITICAL,0.002460000105202198,false,,false,false,false,,false,false,2021-11-09T11:32:04.000Z,0 CVE-2021-27386,https://securityvulnerability.io/vulnerability/CVE-2021-27386,,"A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\"" & 15\"" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\"" & 15\"" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI Comfort Panels V15 4\"" - 22\"" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\"" - 22\"" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (All versions < V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (All versions < V16 Update 4), SINAMICS GH150 (All versions), SINAMICS GL150 (with option X30) (All versions), SINAMICS GM150 (with option X30) (All versions), SINAMICS SH150 (All versions), SINAMICS SL150 (All versions), SINAMICS SM120 (All versions), SINAMICS SM150 (All versions), SINAMICS SM150i (All versions). SmartVNC has a heap allocation leak vulnerability in the device layout handler on client side, which could result in a Denial-of-Service condition.",Siemens,"Simatic Hmi Comfort Outdoor Panels V15 7\"" & 15\"" (incl. Siplus Variants),Simatic Hmi Comfort Outdoor Panels V16 7\"" & 15\"" (incl. Siplus Variants),Simatic Hmi Comfort Panels V15 4\"" - 22\"" (incl. Siplus Variants),Simatic Hmi Comfort Panels V16 4\"" - 22\"" (incl. Siplus Variants),Simatic Hmi Ktp Mobile Panels V15 Ktp400f, Ktp700, Ktp700f, Ktp900 And Ktp900f,Simatic Hmi Ktp Mobile Panels V16 Ktp400f, Ktp700, Ktp700f, Ktp900 And Ktp900f,Simatic Wincc Runtime Advanced V15,Simatic Wincc Runtime Advanced V16,Sinamics Gh150,Sinamics Gl150 (with Option X30),Sinamics Gm150 (with Option X30),Sinamics Sh150,Sinamics Sl150,Sinamics Sm120,Sinamics Sm150,Sinamics Sm150i",7.5,HIGH,0.004809999838471413,false,,false,false,false,,false,false,2021-05-12T13:18:23.000Z,0 CVE-2021-27385,https://securityvulnerability.io/vulnerability/CVE-2021-27385,,"A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\"" & 15\"" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\"" & 15\"" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI Comfort Panels V15 4\"" - 22\"" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\"" - 22\"" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (All versions < V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (All versions < V16 Update 4), SINAMICS GH150 (All versions), SINAMICS GL150 (with option X30) (All versions), SINAMICS GM150 (with option X30) (All versions), SINAMICS SH150 (All versions), SINAMICS SL150 (All versions), SINAMICS SM120 (All versions), SINAMICS SM150 (All versions), SINAMICS SM150i (All versions). A remote attacker could send specially crafted packets to SmartVNC device layout handler on client side, which could influence the amount of resources consumed and result in a Denial-of-Service (infinite loop) condition.",Siemens,"Simatic Hmi Comfort Outdoor Panels V15 7\"" & 15\"" (incl. Siplus Variants),Simatic Hmi Comfort Outdoor Panels V16 7\"" & 15\"" (incl. Siplus Variants),Simatic Hmi Comfort Panels V15 4\"" - 22\"" (incl. Siplus Variants),Simatic Hmi Comfort Panels V16 4\"" - 22\"" (incl. Siplus Variants),Simatic Hmi Ktp Mobile Panels V15 Ktp400f, Ktp700, Ktp700f, Ktp900 And Ktp900f,Simatic Hmi Ktp Mobile Panels V16 Ktp400f, Ktp700, Ktp700f, Ktp900 And Ktp900f,Simatic Wincc Runtime Advanced V15,Simatic Wincc Runtime Advanced V16,Sinamics Gh150,Sinamics Gl150 (with Option X30),Sinamics Gm150 (with Option X30),Sinamics Sh150,Sinamics Sl150,Sinamics Sm120,Sinamics Sm150,Sinamics Sm150i",7.5,HIGH,0.0029299999587237835,false,,false,false,false,,false,false,2021-05-12T13:18:23.000Z,0 CVE-2021-25661,https://securityvulnerability.io/vulnerability/CVE-2021-25661,,"A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\"" & 15\"" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\"" & 15\"" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI Comfort Panels V15 4\"" - 22\"" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\"" - 22\"" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (All versions < V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (All versions < V16 Update 4). SmartVNC has an out-of-bounds memory access vulnerability that could be triggered on the client side when sending data from the server, which could result in a Denial-of-Service condition.",Siemens,"Simatic Hmi Comfort Outdoor Panels V15 7\"" & 15\"" (incl. Siplus Variants),Simatic Hmi Comfort Outdoor Panels V16 7\"" & 15\"" (incl. Siplus Variants),Simatic Hmi Comfort Panels V15 4\"" - 22\"" (incl. Siplus Variants),Simatic Hmi Comfort Panels V16 4\"" - 22\"" (incl. Siplus Variants),Simatic Hmi Ktp Mobile Panels V15 Ktp400f, Ktp700, Ktp700f, Ktp900 And Ktp900f,Simatic Hmi Ktp Mobile Panels V16 Ktp400f, Ktp700, Ktp700f, Ktp900 And Ktp900f,Simatic Wincc Runtime Advanced V15,Simatic Wincc Runtime Advanced V16",7.5,HIGH,0.0014600000577047467,false,,false,false,false,,false,false,2021-05-12T13:18:22.000Z,0 CVE-2021-27383,https://securityvulnerability.io/vulnerability/CVE-2021-27383,,"A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\"" & 15\"" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\"" & 15\"" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI Comfort Panels V15 4\"" - 22\"" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\"" - 22\"" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (All versions < V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (All versions < V16 Update 4), SINAMICS GH150 (All versions), SINAMICS GL150 (with option X30) (All versions), SINAMICS GM150 (with option X30) (All versions), SINAMICS SH150 (All versions), SINAMICS SL150 (All versions), SINAMICS SM120 (All versions), SINAMICS SM150 (All versions), SINAMICS SM150i (All versions). SmartVNC has a heap allocation leak vulnerability in the server Tight encoder, which could result in a Denial-of-Service condition.",Siemens,"Simatic Hmi Comfort Outdoor Panels V15 7\"" & 15\"" (incl. Siplus Variants),Simatic Hmi Comfort Outdoor Panels V16 7\"" & 15\"" (incl. Siplus Variants),Simatic Hmi Comfort Panels V15 4\"" - 22\"" (incl. Siplus Variants),Simatic Hmi Comfort Panels V16 4\"" - 22\"" (incl. Siplus Variants),Simatic Hmi Ktp Mobile Panels V15 Ktp400f, Ktp700, Ktp700f, Ktp900 And Ktp900f,Simatic Hmi Ktp Mobile Panels V16 Ktp400f, Ktp700, Ktp700f, Ktp900 And Ktp900f,Simatic Wincc Runtime Advanced V15,Simatic Wincc Runtime Advanced V16,Sinamics Gh150,Sinamics Gl150 (with Option X30),Sinamics Gm150 (with Option X30),Sinamics Sh150,Sinamics Sl150,Sinamics Sm120,Sinamics Sm150,Sinamics Sm150i",7.5,HIGH,0.0016599999507889152,false,,false,false,false,,false,false,2021-05-12T13:18:22.000Z,0 CVE-2021-27384,https://securityvulnerability.io/vulnerability/CVE-2021-27384,,"A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\"" & 15\"" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\"" & 15\"" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI Comfort Panels V15 4\"" - 22\"" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\"" - 22\"" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (All versions < V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (All versions < V16 Update 4), SINAMICS GH150 (All versions), SINAMICS GL150 (with option X30) (All versions), SINAMICS GM150 (with option X30) (All versions), SINAMICS SH150 (All versions), SINAMICS SL150 (All versions), SINAMICS SM120 (All versions), SINAMICS SM150 (All versions), SINAMICS SM150i (All versions). SmartVNC has an out-of-bounds memory access vulnerability in the device layout handler, represented by a binary data stream on client side, which can potentially result in code execution.",Siemens,"Simatic Hmi Comfort Outdoor Panels V15 7\"" & 15\"" (incl. Siplus Variants),Simatic Hmi Comfort Outdoor Panels V16 7\"" & 15\"" (incl. Siplus Variants),Simatic Hmi Comfort Panels V15 4\"" - 22\"" (incl. Siplus Variants),Simatic Hmi Comfort Panels V16 4\"" - 22\"" (incl. Siplus Variants),Simatic Hmi Ktp Mobile Panels V15 Ktp400f, Ktp700, Ktp700f, Ktp900 And Ktp900f,Simatic Hmi Ktp Mobile Panels V16 Ktp400f, Ktp700, Ktp700f, Ktp900 And Ktp900f,Simatic Wincc Runtime Advanced V15,Simatic Wincc Runtime Advanced V16,Sinamics Gh150,Sinamics Gl150 (with Option X30),Sinamics Gm150 (with Option X30),Sinamics Sh150,Sinamics Sl150,Sinamics Sm120,Sinamics Sm150,Sinamics Sm150i",9.8,CRITICAL,0.005330000072717667,false,,false,false,false,,false,false,2021-05-12T13:18:22.000Z,0 CVE-2021-25660,https://securityvulnerability.io/vulnerability/CVE-2021-25660,,"A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\"" & 15\"" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\"" & 15\"" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI Comfort Panels V15 4\"" - 22\"" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\"" - 22\"" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (All versions < V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (All versions < V16 Update 4). SmartVNC has an out-of-bounds memory access vulnerability that could be triggered on the server side when sending data from the client, which could result in a Denial-of-Service condition.",Siemens,"Simatic Hmi Comfort Outdoor Panels V15 7\"" & 15\"" (incl. Siplus Variants),Simatic Hmi Comfort Outdoor Panels V16 7\"" & 15\"" (incl. Siplus Variants),Simatic Hmi Comfort Panels V15 4\"" - 22\"" (incl. Siplus Variants),Simatic Hmi Comfort Panels V16 4\"" - 22\"" (incl. Siplus Variants),Simatic Hmi Ktp Mobile Panels V15 Ktp400f, Ktp700, Ktp700f, Ktp900 And Ktp900f,Simatic Hmi Ktp Mobile Panels V16 Ktp400f, Ktp700, Ktp700f, Ktp900 And Ktp900f,Simatic Wincc Runtime Advanced V15,Simatic Wincc Runtime Advanced V16",7.5,HIGH,0.0014700000174343586,false,,false,false,false,,false,false,2021-05-12T13:18:22.000Z,0 CVE-2021-25662,https://securityvulnerability.io/vulnerability/CVE-2021-25662,,"A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\"" & 15\"" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\"" & 15\"" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI Comfort Panels V15 4\"" - 22\"" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\"" - 22\"" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (All versions < V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (All versions < V16 Update 4). SmartVNC client fails to handle an exception properly if the program execution process is modified after sending a packet from the server, which could result in a Denial-of-Service condition.",Siemens,"Simatic Hmi Comfort Outdoor Panels V15 7\"" & 15\"" (incl. Siplus Variants),Simatic Hmi Comfort Outdoor Panels V16 7\"" & 15\"" (incl. Siplus Variants),Simatic Hmi Comfort Panels V15 4\"" - 22\"" (incl. Siplus Variants),Simatic Hmi Comfort Panels V16 4\"" - 22\"" (incl. Siplus Variants),Simatic Hmi Ktp Mobile Panels V15 Ktp400f, Ktp700, Ktp700f, Ktp900 And Ktp900f,Simatic Hmi Ktp Mobile Panels V16 Ktp400f, Ktp700, Ktp700f, Ktp900 And Ktp900f,Simatic Wincc Runtime Advanced V15,Simatic Wincc Runtime Advanced V16",7.5,HIGH,0.008379999548196793,false,,false,false,false,,false,false,2021-05-12T13:18:22.000Z,0 CVE-2020-7580,https://securityvulnerability.io/vulnerability/CVE-2020-7580,,"A vulnerability has been identified in SIMATIC Automation Tool (All versions < V4 SP2), SIMATIC NET PC Software V14 (All versions < V14 SP1 Update 14), SIMATIC NET PC Software V15 (All versions), SIMATIC NET PC Software V16 (All versions < V16 Upd3), SIMATIC PCS neo (All versions < V3.0 SP1), SIMATIC ProSave (All versions < V17), SIMATIC S7-1500 Software Controller (All versions < V21.8), SIMATIC STEP 7 (TIA Portal) V13 (All versions < V13 SP2 Update 4), SIMATIC STEP 7 (TIA Portal) V14 (All versions < V14 SP1 Update 10), SIMATIC STEP 7 (TIA Portal) V15 (All versions < V15.1 Update 5), SIMATIC STEP 7 (TIA Portal) V16 (All versions < V16 Update 2), SIMATIC STEP 7 V5 (All versions < V5.6 SP2 HF3), SIMATIC WinCC OA V3.16 (All versions < V3.16 P018), SIMATIC WinCC OA V3.17 (All versions < V3.17 P003), SIMATIC WinCC Runtime Advanced (All versions < V16 Update 2), SIMATIC WinCC Runtime Professional V13 (All versions < V13 SP2 Update 4), SIMATIC WinCC Runtime Professional V14 (All versions < V14 SP1 Update 10), SIMATIC WinCC Runtime Professional V15 (All versions < V15.1 Update 5), SIMATIC WinCC Runtime Professional V16 (All versions < V16 Update 2), SIMATIC WinCC V7.4 (All versions < V7.4 SP1 Update 14), SIMATIC WinCC V7.5 (All versions < V7.5 SP1 Update 3), SINAMICS STARTER (All Versions < V5.4 HF2), SINAMICS Startdrive (All Versions < V16 Update 3), SINEC NMS (All versions < V1.0 SP2), SINEMA Server (All versions < V14 SP3), SINUMERIK ONE virtual (All Versions < V6.14), SINUMERIK Operate (All Versions < V6.14). A common component used by the affected applications regularly calls a helper binary with SYSTEM privileges while the call path is not quoted. This could allow a local attacker to execute arbitrary code with SYTEM privileges.",Siemens,"Simatic Automation Tool,Simatic Net Pc Software V14,Simatic Net Pc Software V15,Simatic Net Pc Software V16,Simatic Pcs Neo,Simatic Prosave,Simatic S7-1500 Software Controller,Simatic Step 7 (tia Portal) V13,Simatic Step 7 (tia Portal) V14,Simatic Step 7 (tia Portal) V15,Simatic Step 7 (tia Portal) V16,Simatic Step 7 V5,Simatic Wincc Oa V3.16,Simatic Wincc Oa V3.17,Simatic Wincc Runtime Advanced,Simatic Wincc Runtime Professional V13,Simatic Wincc Runtime Professional V14,Simatic Wincc Runtime Professional V15,Simatic Wincc Runtime Professional V16,Simatic Wincc V7.4,Simatic Wincc V7.5,Sinamics Starter,Sinamics Startdrive,Sinec Nms,Sinema Server,Sinumerik One Virtual,Sinumerik Operate",6.7,MEDIUM,0.0004600000102072954,false,,false,false,false,,false,false,2020-06-10T00:00:00.000Z,0 CVE-2019-19282,https://securityvulnerability.io/vulnerability/CVE-2019-19282,,"A vulnerability has been identified in OpenPCS 7 V8.1 (All versions), OpenPCS 7 V8.2 (All versions), OpenPCS 7 V9.0 (All versions < V9.0 Upd3), SIMATIC BATCH V8.1 (All versions), SIMATIC BATCH V8.2 (All versions < V8.2 Upd12), SIMATIC BATCH V9.0 (All versions < V9.0 SP1 Upd5), SIMATIC NET PC Software V14 (All versions < V14 SP1 Update 14), SIMATIC NET PC Software V15 (All versions), SIMATIC NET PC Software V16 (All versions < V16 Update 1), SIMATIC PCS 7 V8.1 (All versions), SIMATIC PCS 7 V8.2 (All versions), SIMATIC PCS 7 V9.0 (All versions < V9.0 SP3), SIMATIC Route Control V8.1 (All versions), SIMATIC Route Control V8.2 (All versions), SIMATIC Route Control V9.0 (All versions < V9.0 Upd4), SIMATIC WinCC (TIA Portal) V13 (All versions < V13 SP2), SIMATIC WinCC (TIA Portal) V14 (All versions < V14 SP1 Update 10), SIMATIC WinCC (TIA Portal) V15.1 (All versions < V15.1 Update 5), SIMATIC WinCC (TIA Portal) V16 (All versions < V16 Update 1), SIMATIC WinCC V7.3 (All versions), SIMATIC WinCC V7.4 (All versions < V7.4 SP1 Update 14), SIMATIC WinCC V7.5 (All versions < V7.5 SP1 Update 1). Through specially crafted messages, when encrypted communication is enabled, an attacker with network access could use the vulnerability to compromise the availability of the system by causing a Denial-of-Service condition. Successful exploitation requires no system privileges and no user interaction.",Siemens,"Openpcs 7 V8.1,Openpcs 7 V8.2,Openpcs 7 V9.0,Simatic Batch V8.1,Simatic Batch V8.2,Simatic Batch V9.0,Simatic Net Pc Software V14,Simatic Net Pc Software V15,Simatic Net Pc Software V16,Simatic Pcs 7 V8.1,Simatic Pcs 7 V8.2,Simatic Pcs 7 V9.0,Simatic Route Control V8.1,Simatic Route Control V8.2,Simatic Route Control V9.0,Simatic Wincc (tia Portal) V13,Simatic Wincc (tia Portal) V14,Simatic Wincc (tia Portal) V15.1,Simatic Wincc (tia Portal) V16,Simatic Wincc V7.3,Simatic Wincc V7.4,Simatic Wincc V7.5",7.5,HIGH,0.0010600000387057662,false,,false,false,false,,false,false,2020-03-10T19:16:17.000Z,0