cve,link,title,description,vendor,products,score,severity,epss,cisa,cisa_published,article,ransomware,exploited,poc,trended,trended_no_1,published,trended_score CVE-2024-35783,https://securityvulnerability.io/vulnerability/CVE-2024-35783,Elevated Privileges Vulnerability Affects Siemens' Industrial Automation Products,"A vulnerability affects various Siemens SIMATIC products, specifically allowing the database server to operate with elevated privileges. This situation provides a potential opportunity for authenticated attackers to execute arbitrary operating system commands, posing a significant security risk to the affected systems. Products including SIMATIC BATCH, SIMATIC Information Server, and multiple versions of SIMATIC WinCC have been identified as vulnerable. Proper mitigation measures should be employed to safeguard against potential exploitation.",Siemens,"Simatic Batch V9.1,Simatic Information Server 2020,Simatic Information Server 2022,Simatic Pcs 7 V9.1,Simatic Process Historian 2020,Simatic Process Historian 2022,Simatic Wincc Runtime Professional V18,Simatic Wincc Runtime Professional V19,Simatic Wincc V7.4,Simatic Wincc V7.5,Simatic Wincc V8.0",9.1,CRITICAL,0.0004299999854993075,false,,false,false,false,,false,false,2024-09-10T09:36:32.225Z,0 CVE-2024-30321,https://securityvulnerability.io/vulnerability/CVE-2024-30321,Information Disclosure in Siemens SIMATIC Products,"A vulnerability has been identified in specific versions of Siemens SIMATIC PCS 7, WinCC Runtime Professional, and WinCC products. The issue arises due to improper handling of certain requests within their web applications, potentially allowing unauthenticated remote attackers to access sensitive information, such as user credentials. This poses significant risks to organizations utilizing these systems, emphasizing the need for immediate updates to the latest patches.",Siemens,"Simatic Pcs 7 V9.1,Simatic Wincc Runtime Professional V18,Simatic Wincc Runtime Professional V19,Simatic Wincc V7.4,Simatic Wincc V7.5,Simatic Wincc V8.0",5.9,MEDIUM,0.0004299999854993075,false,,false,false,false,,false,false,2024-07-09T12:15:00.000Z,0 CVE-2023-46280,https://securityvulnerability.io/vulnerability/CVE-2023-46280,Out of Bounds Read Vulnerability in SIMATIC and TIA Portal Products by Siemens,"An out of bounds read vulnerability has been identified in multiple Siemens products, including the SIMATIC and TIA Portal series. This flaw can potentially lead to the crashing of the Windows kernel, resulting in a Blue Screen of Death (BSOD) error. Attackers could exploit this vulnerability to destabilize systems, impacting operational efficiency and safety within industrial environments. It is crucial for users of these products to be aware of this vulnerability and to implement necessary mitigations as outlined by Siemens.",Siemens,"Security Configuration Tool (sct),Simatic Automation Tool,Simatic Batch V9.1,Simatic Net Pc Software V16,Simatic Net Pc Software V17,Simatic Net Pc Software V18,Simatic Net Pc Software V19,Simatic Pcs 7 V9.1,Simatic Pdm V9.2,Simatic Route Control V9.1,Simatic S7-pct,Simatic Step 7 V5,Simatic Wincc Oa V3.17,Simatic Wincc Oa V3.18,Simatic Wincc Oa V3.19,Simatic Wincc Runtime Advanced,Simatic Wincc Runtime Professional V16,Simatic Wincc Runtime Professional V17,Simatic Wincc Runtime Professional V18,Simatic Wincc Runtime Professional V19,Simatic Wincc V7.4,Simatic Wincc V7.5,Simatic Wincc V8.0,Sinamics Startdrive,Sinec Nms,Sinumerik One Virtual,Sinumerik Plc Programming Tool,Tia Portal Cloud Connector,Totally Integrated Automation Portal (tia Portal) V15.1,Totally Integrated Automation Portal (tia Portal) V16,Totally Integrated Automation Portal (tia Portal) V17,Totally Integrated Automation Portal (tia Portal) V18,Totally Integrated Automation Portal (tia Portal) V19",6.5,MEDIUM,0.00044999999227002263,false,,false,false,false,,false,false,2024-05-14T10:01:52.069Z,0 CVE-2023-48364,https://securityvulnerability.io/vulnerability/CVE-2023-48364,Remote Procedure Call Vulnerability in OpenPCS and SIMATIC Products by Siemens,"A vulnerability exists in certain Siemens OpenPCS and SIMATIC products due to improper handling of malformed Remote Procedure Call (RPC) messages. This oversight could allow an attacker to exploit the vulnerability, leading to a denial of service condition in the RPC server, thereby impacting the availability and functionality of the affected systems. It is crucial for users to apply the updates provided by Siemens to mitigate potential risks associated with this vulnerability.",Siemens,"Openpcs 7 V9.1,Simatic Batch V9.1,Simatic Pcs 7 V9.1,Simatic Route Control V9.1,Simatic Wincc Runtime Professional V18,Simatic Wincc Runtime Professional V19,Simatic Wincc V7.4,Simatic Wincc V7.5,Simatic Wincc V8.0",6.5,MEDIUM,0.0004400000034365803,false,,false,false,false,,false,false,2024-02-13T08:59:56.648Z,0 CVE-2023-48363,https://securityvulnerability.io/vulnerability/CVE-2023-48363,Remote Procedure Call Vulnerability in Siemens OpenPCS and SIMATIC Products,"A vulnerability exists in certain versions of Siemens OpenPCS and SIMATIC products due to improper handling of specific unorganized Remote Procedure Call (RPC) messages. This flaw can be exploited by an attacker to trigger a denial of service condition in the RPC server, potentially disrupting operations across affected systems. Timely updates to the latest service packs are recommended to mitigate this risk.",Siemens,"Openpcs 7 V9.1,Simatic Batch V9.1,Simatic Pcs 7 V9.1,Simatic Route Control V9.1,Simatic Wincc Runtime Professional V18,Simatic Wincc Runtime Professional V19,Simatic Wincc V7.4,Simatic Wincc V7.5,Simatic Wincc V8.0",6.5,MEDIUM,0.0004400000034365803,false,,false,false,false,,false,false,2024-02-13T08:59:55.432Z,0 CVE-2023-28831,https://securityvulnerability.io/vulnerability/CVE-2023-28831,Integer Overflow Issue in Siemens OPC UA Implementations,"The OPC UA implementations in Siemens products harbor an integer overflow vulnerability that can lead to an infinite loop during the certificate validation process. This condition could be exploited by an unauthenticated remote attacker utilizing a specially crafted certificate, resulting in a denial of service that impacts application availability and reliability.",Siemens,"Simatic Braumat,Simatic Cloud Connect 7 Cc712,Simatic Cloud Connect 7 Cc716,Simatic Comfort/mobile Rt,Simatic Drive Controller Cpu 1504d Tf,Simatic Drive Controller Cpu 1507d Tf,Simatic Et 200sp Open Controller Cpu 1515sp Pc2 (incl. Siplus Variants),Simatic Ipc Diagmonitor,Simatic Net Pc Software V14,Simatic Net Pc Software V16,Simatic Net Pc Software V17,Simatic Net Pc Software V18,Simatic Pcs 7 V9.1,Simatic Pcs Neo V4.0,Simatic S7-1500 Cpu 1510sp F-1 Pn,Simatic S7-1500 Cpu 1510sp-1 Pn,Simatic S7-1500 Cpu 1511-1 Pn,Simatic S7-1500 Cpu 1511c-1 Pn,Simatic S7-1500 Cpu 1511f-1 Pn,Simatic S7-1500 Cpu 1511t-1 Pn,Simatic S7-1500 Cpu 1511tf-1 Pn,Simatic S7-1500 Cpu 1512c-1 Pn,Simatic S7-1500 Cpu 1512sp F-1 Pn,Simatic S7-1500 Cpu 1512sp-1 Pn,Simatic S7-1500 Cpu 1513-1 Pn,Simatic S7-1500 Cpu 1513f-1 Pn,Simatic S7-1500 Cpu 1514sp F-2 Pn,Simatic S7-1500 Cpu 1514sp-2 Pn,Simatic S7-1500 Cpu 1514spt F-2 Pn,Simatic S7-1500 Cpu 1514spt-2 Pn,Simatic S7-1500 Cpu 1515-2 Pn,Simatic S7-1500 Cpu 1515f-2 Pn,Simatic S7-1500 Cpu 1515t-2 Pn,Simatic S7-1500 Cpu 1515tf-2 Pn,Simatic S7-1500 Cpu 1516-3 Pn/dp,Simatic S7-1500 Cpu 1516f-3 Pn/dp,Simatic S7-1500 Cpu 1516t-3 Pn/dp,Simatic S7-1500 Cpu 1516tf-3 Pn/dp,Simatic S7-1500 Cpu 1517-3 Pn/dp,Simatic S7-1500 Cpu 1517f-3 Pn/dp,Simatic S7-1500 Cpu 1517t-3 Pn/dp,Simatic S7-1500 Cpu 1517tf-3 Pn/dp,Simatic S7-1500 Cpu 1518-4 Pn/dp,Simatic S7-1500 Cpu 1518-4 Pn/dp Mfp,Simatic S7-1500 Cpu 1518f-4 Pn/dp,Simatic S7-1500 Cpu 1518f-4 Pn/dp Mfp,Simatic S7-1500 Cpu 1518t-4 Pn/dp,Simatic S7-1500 Cpu 1518tf-4 Pn/dp,Simatic S7-1500 Cpu S7-1518-4 Pn/dp Odk,Simatic S7-1500 Cpu S7-1518f-4 Pn/dp Odk,Simatic S7-1500 Et 200pro: Cpu 1513pro F-2 Pn,Simatic S7-1500 Et 200pro: Cpu 1513pro-2 Pn,Simatic S7-1500 Et 200pro: Cpu 1516pro F-2 Pn,Simatic S7-1500 Et 200pro: Cpu 1516pro-2 Pn,Simatic S7-1500 Software Controller V2,Simatic S7-1500 Software Controller V3,Simatic S7-plcsim Advanced,Simatic Sistar,Simatic Wincc Oa V3.17,Simatic Wincc Oa V3.18,Simatic Wincc Oa V3.19,Simatic Wincc Opc Ua Client,Simatic Wincc Runtime Professional V16,Simatic Wincc Runtime Professional V17,Simatic Wincc Runtime Professional V18,Simatic Wincc Runtime Professional V19,Simatic Wincc Unified Opc Ua Server,Simatic Wincc V7.4,Simatic Wincc V7.5,Simatic Wincc V8.0,Sinumerik Mc,Sinumerik One,Siplus Et 200sp Cpu 1510sp F-1 Pn,Siplus Et 200sp Cpu 1510sp F-1 Pn Rail,Siplus Et 200sp Cpu 1510sp-1 Pn,Siplus Et 200sp Cpu 1510sp-1 Pn Rail,Siplus Et 200sp Cpu 1512sp F-1 Pn,Siplus Et 200sp Cpu 1512sp F-1 Pn Rail,Siplus Et 200sp Cpu 1512sp-1 Pn,Siplus Et 200sp Cpu 1512sp-1 Pn Rail,Siplus S7-1500 Cpu 1511-1 Pn,Siplus S7-1500 Cpu 1511-1 Pn T1 Rail,Siplus S7-1500 Cpu 1511-1 Pn Tx Rail,Siplus S7-1500 Cpu 1511f-1 Pn,Siplus S7-1500 Cpu 1513-1 Pn,Siplus S7-1500 Cpu 1513f-1 Pn,Siplus S7-1500 Cpu 1515f-2 Pn,Siplus S7-1500 Cpu 1515f-2 Pn Rail,Siplus S7-1500 Cpu 1515f-2 Pn T2 Rail,Siplus S7-1500 Cpu 1516-3 Pn/dp,Siplus S7-1500 Cpu 1516-3 Pn/dp Rail,Siplus S7-1500 Cpu 1516-3 Pn/dp Tx Rail,Siplus S7-1500 Cpu 1516f-3 Pn/dp,Siplus S7-1500 Cpu 1516f-3 Pn/dp Rail,Siplus S7-1500 Cpu 1518-4 Pn/dp,Siplus S7-1500 Cpu 1518-4 Pn/dp Mfp,Siplus S7-1500 Cpu 1518f-4 Pn/dp",7.5,HIGH,0.0005300000193528831,false,,false,false,false,,false,false,2023-09-12T10:15:00.000Z,0 CVE-2022-24287,https://securityvulnerability.io/vulnerability/CVE-2022-24287,Vulnerability in Siemens SIMATIC Products Allows Kiosk Mode Escape,"A security flaw in Siemens' SIMATIC products allows an authenticated attacker to bypass the Kiosk Mode due to a missing printer configuration on the host. This vulnerability affects various versions of the SIMATIC PCS 7 and WinCC products, which could potentially lead to unauthorized access and manipulation of the systems. It is critical for users to ensure correct printer configurations to mitigate this risk effectively.",Siemens,"Simatic Pcs 7 V8.2,Simatic Pcs 7 V9.0,Simatic Pcs 7 V9.1,Simatic Wincc Runtime Professional V16 And Earlier,Simatic Wincc Runtime Professional V17,Simatic Wincc V7.3,Simatic Wincc V7.4,Simatic Wincc V7.5",7.8,HIGH,0.0004400000034365803,false,,false,false,false,,false,false,2022-05-20T13:15:00.000Z,0 CVE-2021-40363,https://securityvulnerability.io/vulnerability/CVE-2021-40363,,"A vulnerability has been identified in SIMATIC PCS 7 V8.2 (All versions), SIMATIC PCS 7 V9.0 (All versions), SIMATIC PCS 7 V9.1 (All versions < V9.1 SP1), SIMATIC WinCC V15 and earlier (All versions < V15 SP1 Update 7), SIMATIC WinCC V16 (All versions < V16 Update 5), SIMATIC WinCC V17 (All versions < V17 Update 2), SIMATIC WinCC V17 (All versions <= V17 Update 4), SIMATIC WinCC V7.4 (All versions < V7.4 SP1 Update 19), SIMATIC WinCC V7.5 (All versions < V7.5 SP2 Update 6). The affected component stores the credentials of a local system account in a potentially publicly accessible project file using an outdated cipher algorithm. An attacker may use this to brute force the credentials and take over the system.",Siemens,"Simatic Pcs 7 V8.2,Simatic Pcs 7 V9.0,Simatic Pcs 7 V9.1,Simatic Wincc V15 And Earlier,Simatic Wincc V16,Simatic Wincc V17,Simatic Wincc V7.4,Simatic Wincc V7.5",7.8,HIGH,0.0004400000034365803,false,,false,false,false,,false,false,2022-02-09T15:17:04.000Z,0 CVE-2021-40360,https://securityvulnerability.io/vulnerability/CVE-2021-40360,,"A vulnerability has been identified in SIMATIC PCS 7 V8.2 (All versions), SIMATIC PCS 7 V9.0 (All versions), SIMATIC PCS 7 V9.1 (All versions < V9.1 SP1), SIMATIC WinCC V15 and earlier (All versions < V15 SP1 Update 7), SIMATIC WinCC V16 (All versions < V16 Update 5), SIMATIC WinCC V17 (All versions < V17 Update 2), SIMATIC WinCC V7.4 (All versions < V7.4 SP1 Update 19), SIMATIC WinCC V7.5 (All versions < V7.5 SP2 Update 6). The password hash of a local user account in the remote server could be granted via public API to a user on the affected system. An authenticated attacker could brute force the password hash and use it to login to the server.",Siemens,"Simatic Pcs 7 V8.2,Simatic Pcs 7 V9.0,Simatic Pcs 7 V9.1,Simatic Wincc V15 And Earlier,Simatic Wincc V16,Simatic Wincc V17,Simatic Wincc V7.4,Simatic Wincc V7.5",8.8,HIGH,0.0008800000068731606,false,,false,false,false,,false,false,2022-02-09T15:17:03.000Z,0 CVE-2021-40364,https://securityvulnerability.io/vulnerability/CVE-2021-40364,,"A vulnerability has been identified in SIMATIC PCS 7 V8.2 (All versions), SIMATIC PCS 7 V9.0 (All versions < V9.0 SP3 UC04), SIMATIC PCS 7 V9.1 (All versions < V9.1 SP1), SIMATIC WinCC V15 and earlier (All versions < V15 SP1 Update 7), SIMATIC WinCC V16 (All versions < V16 Update 5), SIMATIC WinCC V17 (All versions < V17 Update 2), SIMATIC WinCC V7.4 (All versions < V7.4 SP1 Update 19), SIMATIC WinCC V7.5 (All versions < V7.5 SP2 Update 5). The affected systems store sensitive information in log files. An attacker with access to the log files could publicly expose the information or reuse it to develop further attacks on the system.",Siemens,"Simatic Pcs 7 V8.2,Simatic Pcs 7 V9.0,Simatic Pcs 7 V9.1,Simatic Wincc V15 And Earlier,Simatic Wincc V16,Simatic Wincc V17,Simatic Wincc V7.4,Simatic Wincc V7.5",5.5,MEDIUM,0.00139999995008111,false,,false,false,false,,false,false,2021-11-09T11:32:06.000Z,0 CVE-2021-40359,https://securityvulnerability.io/vulnerability/CVE-2021-40359,,"A vulnerability has been identified in OpenPCS 7 V8.2 (All versions), OpenPCS 7 V9.0 (All versions < V9.0 Upd4), OpenPCS 7 V9.1 (All versions), SIMATIC BATCH V8.2 (All versions), SIMATIC BATCH V9.0 (All versions), SIMATIC BATCH V9.1 (All versions), SIMATIC NET PC Software V14 (All versions), SIMATIC NET PC Software V15 (All versions), SIMATIC NET PC Software V16 (All versions < V16 Update 6), SIMATIC NET PC Software V17 (All versions < V17 SP1), SIMATIC PCS 7 V8.2 (All versions), SIMATIC PCS 7 V9.0 (All versions < V9.0 SP3 UC04), SIMATIC PCS 7 V9.1 (All versions < V9.1 SP1), SIMATIC Route Control V8.2 (All versions), SIMATIC Route Control V9.0 (All versions), SIMATIC Route Control V9.1 (All versions), SIMATIC WinCC V15 and earlier (All versions < V15 SP1 Update 7), SIMATIC WinCC V16 (All versions < V16 Update 5), SIMATIC WinCC V17 (All versions < V17 Update 2), SIMATIC WinCC V7.4 (All versions < V7.4 SP1 Update 19), SIMATIC WinCC V7.5 (All versions < V7.5 SP2 Update 5). When downloading files, the affected systems do not properly neutralize special elements within the pathname. An attacker could then cause the pathname to resolve to a location outside of the restricted directory on the server and read unexpected critical files.",Siemens,"Openpcs 7 V8.2,Openpcs 7 V9.0,Openpcs 7 V9.1,Simatic Batch V8.2,Simatic Batch V9.0,Simatic Batch V9.1,Simatic Net Pc Software V14,Simatic Net Pc Software V15,Simatic Net Pc Software V16,Simatic Net Pc Software V17,Simatic Pcs 7 V8.2,Simatic Pcs 7 V9.0,Simatic Pcs 7 V9.1,Simatic Route Control V8.2,Simatic Route Control V9.0,Simatic Route Control V9.1,Simatic Wincc V15 And Earlier,Simatic Wincc V16,Simatic Wincc V17,Simatic Wincc V7.4,Simatic Wincc V7.5",7.7,HIGH,0.0021299999207258224,false,,false,false,false,,false,false,2021-11-09T11:32:05.000Z,0 CVE-2021-40358,https://securityvulnerability.io/vulnerability/CVE-2021-40358,,"A vulnerability has been identified in SIMATIC PCS 7 V8.2 (All versions), SIMATIC PCS 7 V9.0 (All versions < V9.0 SP3 UC04), SIMATIC PCS 7 V9.1 (All versions < V9.1 SP1), SIMATIC WinCC V15 and earlier (All versions < V15 SP1 Update 7), SIMATIC WinCC V16 (All versions < V16 Update 5), SIMATIC WinCC V17 (All versions < V17 Update 2), SIMATIC WinCC V7.4 (All versions < V7.4 SP1 Update 19), SIMATIC WinCC V7.5 (All versions < V7.5 SP2 Update 5). Legitimate file operations on the web server of the affected systems do not properly neutralize special elements within the pathname. An attacker could then cause the pathname to resolve to a location outside of the restricted directory on the server and read, write or delete unexpected critical files.",Siemens,"Simatic Pcs 7 V8.2,Simatic Pcs 7 V9.0,Simatic Pcs 7 V9.1,Simatic Wincc V15 And Earlier,Simatic Wincc V16,Simatic Wincc V17,Simatic Wincc V7.4,Simatic Wincc V7.5",9.9,CRITICAL,0.002460000105202198,false,,false,false,false,,false,false,2021-11-09T11:32:04.000Z,0 CVE-2020-7580,https://securityvulnerability.io/vulnerability/CVE-2020-7580,,"A vulnerability has been identified in SIMATIC Automation Tool (All versions < V4 SP2), SIMATIC NET PC Software V14 (All versions < V14 SP1 Update 14), SIMATIC NET PC Software V15 (All versions), SIMATIC NET PC Software V16 (All versions < V16 Upd3), SIMATIC PCS neo (All versions < V3.0 SP1), SIMATIC ProSave (All versions < V17), SIMATIC S7-1500 Software Controller (All versions < V21.8), SIMATIC STEP 7 (TIA Portal) V13 (All versions < V13 SP2 Update 4), SIMATIC STEP 7 (TIA Portal) V14 (All versions < V14 SP1 Update 10), SIMATIC STEP 7 (TIA Portal) V15 (All versions < V15.1 Update 5), SIMATIC STEP 7 (TIA Portal) V16 (All versions < V16 Update 2), SIMATIC STEP 7 V5 (All versions < V5.6 SP2 HF3), SIMATIC WinCC OA V3.16 (All versions < V3.16 P018), SIMATIC WinCC OA V3.17 (All versions < V3.17 P003), SIMATIC WinCC Runtime Advanced (All versions < V16 Update 2), SIMATIC WinCC Runtime Professional V13 (All versions < V13 SP2 Update 4), SIMATIC WinCC Runtime Professional V14 (All versions < V14 SP1 Update 10), SIMATIC WinCC Runtime Professional V15 (All versions < V15.1 Update 5), SIMATIC WinCC Runtime Professional V16 (All versions < V16 Update 2), SIMATIC WinCC V7.4 (All versions < V7.4 SP1 Update 14), SIMATIC WinCC V7.5 (All versions < V7.5 SP1 Update 3), SINAMICS STARTER (All Versions < V5.4 HF2), SINAMICS Startdrive (All Versions < V16 Update 3), SINEC NMS (All versions < V1.0 SP2), SINEMA Server (All versions < V14 SP3), SINUMERIK ONE virtual (All Versions < V6.14), SINUMERIK Operate (All Versions < V6.14). A common component used by the affected applications regularly calls a helper binary with SYSTEM privileges while the call path is not quoted. This could allow a local attacker to execute arbitrary code with SYTEM privileges.",Siemens,"Simatic Automation Tool,Simatic Net Pc Software V14,Simatic Net Pc Software V15,Simatic Net Pc Software V16,Simatic Pcs Neo,Simatic Prosave,Simatic S7-1500 Software Controller,Simatic Step 7 (tia Portal) V13,Simatic Step 7 (tia Portal) V14,Simatic Step 7 (tia Portal) V15,Simatic Step 7 (tia Portal) V16,Simatic Step 7 V5,Simatic Wincc Oa V3.16,Simatic Wincc Oa V3.17,Simatic Wincc Runtime Advanced,Simatic Wincc Runtime Professional V13,Simatic Wincc Runtime Professional V14,Simatic Wincc Runtime Professional V15,Simatic Wincc Runtime Professional V16,Simatic Wincc V7.4,Simatic Wincc V7.5,Sinamics Starter,Sinamics Startdrive,Sinec Nms,Sinema Server,Sinumerik One Virtual,Sinumerik Operate",6.7,MEDIUM,0.0004600000102072954,false,,false,false,false,,false,false,2020-06-10T00:00:00.000Z,0 CVE-2019-19282,https://securityvulnerability.io/vulnerability/CVE-2019-19282,,"A vulnerability has been identified in OpenPCS 7 V8.1 (All versions), OpenPCS 7 V8.2 (All versions), OpenPCS 7 V9.0 (All versions < V9.0 Upd3), SIMATIC BATCH V8.1 (All versions), SIMATIC BATCH V8.2 (All versions < V8.2 Upd12), SIMATIC BATCH V9.0 (All versions < V9.0 SP1 Upd5), SIMATIC NET PC Software V14 (All versions < V14 SP1 Update 14), SIMATIC NET PC Software V15 (All versions), SIMATIC NET PC Software V16 (All versions < V16 Update 1), SIMATIC PCS 7 V8.1 (All versions), SIMATIC PCS 7 V8.2 (All versions), SIMATIC PCS 7 V9.0 (All versions < V9.0 SP3), SIMATIC Route Control V8.1 (All versions), SIMATIC Route Control V8.2 (All versions), SIMATIC Route Control V9.0 (All versions < V9.0 Upd4), SIMATIC WinCC (TIA Portal) V13 (All versions < V13 SP2), SIMATIC WinCC (TIA Portal) V14 (All versions < V14 SP1 Update 10), SIMATIC WinCC (TIA Portal) V15.1 (All versions < V15.1 Update 5), SIMATIC WinCC (TIA Portal) V16 (All versions < V16 Update 1), SIMATIC WinCC V7.3 (All versions), SIMATIC WinCC V7.4 (All versions < V7.4 SP1 Update 14), SIMATIC WinCC V7.5 (All versions < V7.5 SP1 Update 1). Through specially crafted messages, when encrypted communication is enabled, an attacker with network access could use the vulnerability to compromise the availability of the system by causing a Denial-of-Service condition. Successful exploitation requires no system privileges and no user interaction.",Siemens,"Openpcs 7 V8.1,Openpcs 7 V8.2,Openpcs 7 V9.0,Simatic Batch V8.1,Simatic Batch V8.2,Simatic Batch V9.0,Simatic Net Pc Software V14,Simatic Net Pc Software V15,Simatic Net Pc Software V16,Simatic Pcs 7 V8.1,Simatic Pcs 7 V8.2,Simatic Pcs 7 V9.0,Simatic Route Control V8.1,Simatic Route Control V8.2,Simatic Route Control V9.0,Simatic Wincc (tia Portal) V13,Simatic Wincc (tia Portal) V14,Simatic Wincc (tia Portal) V15.1,Simatic Wincc (tia Portal) V16,Simatic Wincc V7.3,Simatic Wincc V7.4,Simatic Wincc V7.5",7.5,HIGH,0.0010600000387057662,false,,false,false,false,,false,false,2020-03-10T19:16:17.000Z,0 CVE-2019-10935,https://securityvulnerability.io/vulnerability/CVE-2019-10935,,"A vulnerability has been identified in SIMATIC PCS 7 V8.0 and earlier (All versions), SIMATIC PCS 7 V8.1 (All versions < V8.1 with WinCC V7.3 Upd 19), SIMATIC PCS 7 V8.2 (All versions < V8.2 SP1 with WinCC V7.4 SP1 Upd 11), SIMATIC PCS 7 V9.0 (All versions < V9.0 SP2 with WinCC V7.4 SP1 Upd11), SIMATIC WinCC Professional (TIA Portal V13) (All versions), SIMATIC WinCC Professional (TIA Portal V14) (All versions < V14 SP1 Upd 9), SIMATIC WinCC Professional (TIA Portal V15) (All versions < V15.1 Upd 3), SIMATIC WinCC Runtime Professional V13 (All versions), SIMATIC WinCC Runtime Professional V14 (All versions < V14.1 Upd 8), SIMATIC WinCC Runtime Professional V15 (All versions < V15.1 Upd 3), SIMATIC WinCC V7.2 and earlier (All versions), SIMATIC WinCC V7.3 (All versions < V7.3 Upd 19), SIMATIC WinCC V7.4 (All versions < V7.4 SP1 Upd 11), SIMATIC WinCC V7.5 (All versions < V7.5 Upd 3). The SIMATIC WinCC DataMonitor web application of the affected products allows to upload arbitrary ASPX code. The security vulnerability could be exploited by an authenticated attacker with network access to the WinCC DataMonitor application. No user interaction is required to exploit this vulnerability. The vulnerability impacts confidentiality, integrity, and availability of the affected device. At the stage of publishing this security advisory no public exploitation is known.",Siemens Ag,"Simatic Pcs 7 V8.0 And Earlier,Simatic Pcs 7 V8.1,Simatic Pcs 7 V8.2,Simatic Pcs 7 V9.0,Simatic Wincc Professional (tia Portal V13),Simatic Wincc Professional (tia Portal V14),Simatic Wincc Professional (tia Portal V15),Simatic Wincc Runtime Professional V13,Simatic Wincc Runtime Professional V14,Simatic Wincc Runtime Professional V15,Simatic Wincc V7.2 And Earlier,Simatic Wincc V7.3,Simatic Wincc V7.4,Simatic Wincc V7.5",7.2,HIGH,0.0009200000204145908,false,,false,false,false,,false,false,2019-07-11T21:17:47.000Z,0 CVE-2019-10918,https://securityvulnerability.io/vulnerability/CVE-2019-10918,,"A vulnerability has been identified in SIMATIC PCS 7 V8.0 and earlier (All versions), SIMATIC PCS 7 V8.1 (All versions < V8.1 with WinCC V7.3 Upd 19), SIMATIC PCS 7 V8.2 (All versions < V8.2 SP1 with WinCC V7.4 SP1 Upd11), SIMATIC PCS 7 V9.0 (All versions < V9.0 SP2 with WinCC V7.4 SP1 Upd11), SIMATIC WinCC (TIA Portal) V13 (All versions), SIMATIC WinCC (TIA Portal) V14 (All versions < V14 SP1 Upd 9), SIMATIC WinCC (TIA Portal) V15 (All versions < V15.1 Upd 3), SIMATIC WinCC Runtime Professional V13 (All versions), SIMATIC WinCC Runtime Professional V14 (All versions < V14.1 Upd 8), SIMATIC WinCC Runtime Professional V15 (All versions < V15.1 Upd 3), SIMATIC WinCC V7.2 and earlier (All versions), SIMATIC WinCC V7.3 (All versions < V7.3 Upd 19), SIMATIC WinCC V7.4 (All versions < V7.4 SP1 Upd 11), SIMATIC WinCC V7.5 (All versions < V7.5 Upd 3). An authenticatd attacker with network access to the DCOM interface could execute arbitrary commands with SYSTEM privileges. The vulnerability could be exploited by an attacker with network access to the affected system. Successful exploitation requires authentication with a low-privileged user account and no user interaction. An attacker could use the vulnerability to compromise confidentiality and integrity and availability of the affected system. At the time of advisory publication no public exploitation of this security vulnerability was known.",Siemens Ag,"Simatic Pcs 7 V8.0 And Earlier,Simatic Pcs 7 V8.1,Simatic Pcs 7 V8.2,Simatic Pcs 7 V9.0,Simatic Wincc (tia Portal) V13,Simatic Wincc (tia Portal) V14,Simatic Wincc (tia Portal) V15,Simatic Wincc Runtime Professional V13,Simatic Wincc Runtime Professional V14,Simatic Wincc Runtime Professional V15,Simatic Wincc V7.2 And Earlier,Simatic Wincc V7.3,Simatic Wincc V7.4,Simatic Wincc V7.5",8.8,HIGH,0.0009500000160187483,false,,false,false,false,,false,false,2019-05-14T19:54:48.000Z,0 CVE-2019-10917,https://securityvulnerability.io/vulnerability/CVE-2019-10917,,"A vulnerability has been identified in SIMATIC PCS 7 V8.0 and earlier (All versions), SIMATIC PCS 7 V8.1 (All versions < V8.1 with WinCC V7.3 Upd 19), SIMATIC PCS 7 V8.2 (All versions < V8.2 SP1 with WinCC V7.4 SP1 Upd11), SIMATIC PCS 7 V9.0 (All versions < V9.0 SP2 with WinCC V7.4 SP1 Upd11), SIMATIC WinCC (TIA Portal) V13 (All versions), SIMATIC WinCC (TIA Portal) V14 (All versions < V14 SP1 Upd 9), SIMATIC WinCC (TIA Portal) V15 (All versions < V15.1 Upd 3), SIMATIC WinCC Runtime Professional V13 (All versions), SIMATIC WinCC Runtime Professional V14 (All versions < V14.1 Upd 8), SIMATIC WinCC Runtime Professional V15 (All versions < V15.1 Upd 3), SIMATIC WinCC V7.2 and earlier (All versions), SIMATIC WinCC V7.3 (All versions < V7.3 Upd 19), SIMATIC WinCC V7.4 (All versions < V7.4 SP1 Upd 11), SIMATIC WinCC V7.5 (All versions < V7.5 Upd 3). An attacker with local access to the project file could cause a Denial-of-Service condition on the affected product while the project file is loaded. Successful exploitation requires access to the project file. An attacker could use the vulnerability to compromise availability of the affected system. At the time of advisory publication no public exploitation of this security vulnerability was known.",Siemens Ag,"Simatic Pcs 7 V8.0 And Earlier,Simatic Pcs 7 V8.1,Simatic Pcs 7 V8.2,Simatic Pcs 7 V9.0,Simatic Wincc (tia Portal) V13,Simatic Wincc (tia Portal) V14,Simatic Wincc (tia Portal) V15,Simatic Wincc Runtime Professional V13,Simatic Wincc Runtime Professional V14,Simatic Wincc Runtime Professional V15,Simatic Wincc V7.2 And Earlier,Simatic Wincc V7.3,Simatic Wincc V7.4,Simatic Wincc V7.5",5.5,MEDIUM,0.0004199999966658652,false,,false,false,false,,false,false,2019-05-14T19:54:48.000Z,0 CVE-2019-10916,https://securityvulnerability.io/vulnerability/CVE-2019-10916,,"A vulnerability has been identified in SIMATIC PCS 7 V8.0 and earlier (All versions), SIMATIC PCS 7 V8.1 (All versions < V8.1 with WinCC V7.3 Upd 19), SIMATIC PCS 7 V8.2 (All versions < V8.2 SP1 with WinCC V7.4 SP1 Upd11), SIMATIC PCS 7 V9.0 (All versions < V9.0 SP2 with WinCC V7.4 SP1 Upd11), SIMATIC WinCC (TIA Portal) V13 (All versions), SIMATIC WinCC (TIA Portal) V14 (All versions < V14 SP1 Upd 9), SIMATIC WinCC (TIA Portal) V15 (All versions < V15.1 Upd 3), SIMATIC WinCC Runtime Professional V13 (All versions), SIMATIC WinCC Runtime Professional V14 (All versions < V14.1 Upd 8), SIMATIC WinCC Runtime Professional V15 (All versions < V15.1 Upd 3), SIMATIC WinCC V7.2 and earlier (All versions), SIMATIC WinCC V7.3 (All versions < V7.3 Upd 19), SIMATIC WinCC V7.4 (All versions < V7.4 SP1 Upd 11), SIMATIC WinCC V7.5 (All versions < V7.5 Upd 3). An attacker with access to the project file could run arbitrary system commands with the privileges of the local database server. The vulnerability could be exploited by an attacker with access to the project file. The vulnerability does impact the confidentiality, integrity, and availability of the affected system. At the time of advisory publication no public exploitation of this security vulnerability was known.",Siemens Ag,"Simatic Pcs 7 V8.0 And Earlier,Simatic Pcs 7 V8.1,Simatic Pcs 7 V8.2,Simatic Pcs 7 V9.0,Simatic Wincc (tia Portal) V13,Simatic Wincc (tia Portal) V14,Simatic Wincc (tia Portal) V15,Simatic Wincc Runtime Professional V13,Simatic Wincc Runtime Professional V14,Simatic Wincc Runtime Professional V15,Simatic Wincc V7.2 And Earlier,Simatic Wincc V7.3,Simatic Wincc V7.4,Simatic Wincc V7.5",8.8,HIGH,0.0009699999936856329,false,,false,false,false,,false,false,2019-05-14T19:54:48.000Z,0 CVE-2018-4832,https://securityvulnerability.io/vulnerability/CVE-2018-4832,,"A vulnerability has been identified in OpenPCS 7 V7.1 and earlier (All versions), OpenPCS 7 V8.0 (All versions), OpenPCS 7 V8.1 (All versions < V8.1 Upd5), OpenPCS 7 V8.2 (All versions), OpenPCS 7 V9.0 (All versions < V9.0 Upd1), SIMATIC BATCH V7.1 and earlier (All versions), SIMATIC BATCH V8.0 (All versions < V8.0 SP1 Upd21), SIMATIC BATCH V8.1 (All versions < V8.1 SP1 Upd16), SIMATIC BATCH V8.2 (All versions < V8.2 Upd10), SIMATIC BATCH V9.0 (All versions < V9.0 SP1), SIMATIC NET PC Software V14 (All versions < V14 SP1 Update 14), SIMATIC NET PC Software V15 (All versions < 15 SP1), SIMATIC PCS 7 V7.1 and earlier (All versions), SIMATIC PCS 7 V8.0 (All versions), SIMATIC PCS 7 V8.1 (All versions), SIMATIC PCS 7 V8.2 (All versions < V8.2 SP1), SIMATIC PCS 7 V9.0 (All versions < V9.0 SP1), SIMATIC Route Control V7.1 and earlier (All versions), SIMATIC Route Control V8.0 (All versions), SIMATIC Route Control V8.1 (All versions), SIMATIC Route Control V8.2 (All versions), SIMATIC Route Control V9.0 (All versions < V9.0 Upd1), SIMATIC WinCC Runtime Professional V13 (All versions < V13 SP2 Upd2), SIMATIC WinCC Runtime Professional V14 (All versions < V14 SP1 Upd5), SIMATIC WinCC V7.2 and earlier (All versions < WinCC 7.2 Upd 15), SIMATIC WinCC V7.3 (All versions < WinCC 7.3 Upd 16), SIMATIC WinCC V7.4 (All versions < V7.4 SP1 Upd 4), SPPA-T3000 Application Server (All versions < Service Pack R8.2 SP2). Specially crafted messages sent to the RPC service of the affected products could cause a Denial-of-Service condition on the remote and local communication functionality of the affected products. A reboot of the system is required to recover the remote and local communication functionality. Please note that an attacker needs to have network access to the Application Server in order to exploit this vulnerability. At the time of advisory publication no public exploitation of this security vulnerability was known.",Siemens,"Openpcs 7 V7.1 And Earlier,Openpcs 7 V8.0,Openpcs 7 V8.1,Openpcs 7 V8.2,Openpcs 7 V9.0,Simatic Batch V7.1 And Earlier,Simatic Batch V8.0,Simatic Batch V8.1,Simatic Batch V8.2,Simatic Batch V9.0,Simatic Net Pc Software V14,Simatic Net Pc Software V15,Simatic Pcs 7 V7.1 And Earlier,Simatic Pcs 7 V8.0,Simatic Pcs 7 V8.1,Simatic Pcs 7 V8.2,Simatic Pcs 7 V9.0,Simatic Route Control V7.1 And Earlier,Simatic Route Control V8.0,Simatic Route Control V8.1,Simatic Route Control V8.2,Simatic Route Control V9.0,Simatic Wincc Runtime Professional V13,Simatic Wincc Runtime Professional V14,Simatic Wincc V7.2 And Earlier,Simatic Wincc V7.3,Simatic Wincc V7.4,Sppa-t3000 Application Server",7.5,HIGH,0.004120000172406435,false,,false,false,false,,false,false,2018-04-24T17:00:00.000Z,0 CVE-2017-6865,https://securityvulnerability.io/vulnerability/CVE-2017-6865,,"A vulnerability has been identified in Primary Setup Tool (PST) (All versions < V4.2 HF1), SIMATIC Automation Tool (All versions < V3.0), SIMATIC NET PC-Software (All versions < V14 SP1), SIMATIC PCS 7 V8.1 (All versions), SIMATIC PCS 7 V8.2 (All versions < V8.2 SP1), SIMATIC STEP 7 (TIA Portal) V13 (All versions < V13 SP2), SIMATIC STEP 7 (TIA Portal) V14 (All versions < V14 SP1), SIMATIC STEP 7 V5.X (All versions < V5.6), SIMATIC WinAC RTX 2010 SP2 (All versions), SIMATIC WinAC RTX F 2010 SP2 (All versions), SIMATIC WinCC (TIA Portal) V13 (All versions < V13 SP2), SIMATIC WinCC (TIA Portal) V14 (All versions < V14 SP1), SIMATIC WinCC V7.2 and prior (All versions), SIMATIC WinCC V7.3 (All versions < V7.3 Update 15), SIMATIC WinCC V7.4 (All versions < V7.4 SP1 Upd1), SIMATIC WinCC flexible 2008 (All versions < flexible 2008 SP5), SINAUT ST7CC (All versions installed in conjunction with SIMATIC WinCC < V7.3 Update 15), SINEMA Server (All versions < V14), SINUMERIK 808D Programming Tool (All versions < V4.7 SP4 HF2), SMART PC Access (All versions < V2.3), STEP 7 - Micro/WIN SMART (All versions < V2.3), Security Configuration Tool (SCT) (All versions < V5.0). Specially crafted PROFINET DCP broadcast packets sent to the affected products on a local Ethernet segment (Layer 2) could cause a Denial-of-Service condition of some services. The services require manual restart to recover.",Siemens,"Primary Setup Tool (pst),Simatic Automation Tool,Simatic Net Pc-software,Simatic Pcs 7 V8.1,Simatic Pcs 7 V8.2,Simatic Step 7 (tia Portal) V13,Simatic Step 7 (tia Portal) V14,Simatic Step 7 V5.x,Simatic Winac Rtx 2010 Sp2,Simatic Winac Rtx F 2010 Sp2,Simatic Wincc (tia Portal) V13,Simatic Wincc (tia Portal) V14,Simatic Wincc V7.2 And Prior,Simatic Wincc V7.3,Simatic Wincc V7.4,Simatic Wincc Flexible 2008,Sinaut St7cc,Sinema Server,Sinumerik 808d Programming Tool,Smart Pc Access,Step 7 - Micro/win Smart,Security Configuration Tool (sct)",6.5,MEDIUM,0.0006799999973736703,false,,false,false,false,,false,false,2017-05-11T10:00:00.000Z,0