cve,link,title,description,vendor,products,score,severity,epss,cisa,cisa_published,article,ransomware,exploited,poc,trended,trended_no_1,published,trended_score CVE-2024-52051,https://securityvulnerability.io/vulnerability/CVE-2024-52051,"{""Vulnerability in Siemens PLCs and SCADA Systems Could Allow Arbitrary Code Execution""}","A vulnerability exists in various Siemens products, including SIMATIC S7-PLCSIM and TIA Portal, due to improper sanitization of user-controllable input when processing user settings. This flaw could enable local attackers to execute arbitrary commands on the host operating system, leveraging the privileges of the user running the affected software. Organizations utilizing these products should prioritize updates and apply security measures to mitigate potential risks.",Siemens,"Simatic S7-plcsim V17,Simatic S7-plcsim V18,Simatic Step 7 Safety V17,Simatic Step 7 Safety V18,Simatic Step 7 Safety V19,Simatic Step 7 V17,Simatic Step 7 V18,Simatic Step 7 V19,Simatic Wincc Unified Pc Runtime V18,Simatic Wincc Unified Pc Runtime V19,Simatic Wincc Unified V17,Simatic Wincc Unified V18,Simatic Wincc Unified V19,Simatic Wincc V17,Simatic Wincc V18,Simatic Wincc V19,Simocode Es V17,Simocode Es V18,Simocode Es V19,Simotion Scout Tia V5.4 Sp3,Simotion Scout Tia V5.5 Sp1,Simotion Scout Tia V5.6 Sp1,Sinamics Startdrive V17,Sinamics Startdrive V18,Sinamics Startdrive V19,Sirius Safety Es V17 (tia Portal),Sirius Safety Es V18 (tia Portal),Sirius Safety Es V19 (tia Portal),Sirius Soft Starter Es V17 (tia Portal),Sirius Soft Starter Es V18 (tia Portal),Sirius Soft Starter Es V19 (tia Portal),Tia Portal Cloud V17,Tia Portal Cloud V18,Tia Portal Cloud V19",7.3,HIGH,0.0004299999854993075,false,,false,false,false,,false,false,2024-12-10T13:53:57.576Z,0 CVE-2024-49849,https://securityvulnerability.io/vulnerability/CVE-2024-49849,"{""Vulnerability in Siemens Products Could Allow Arbitrary Code Execution""}","A vulnerability has been identified across multiple versions and products within Siemens' SIMATIC and TIA Portal lines. The flaw involves inadequate sanitization of user-controllable input when parsing log files, potentially allowing an attacker to exploit this weakness. This exploitation may lead to type confusion and the execution of arbitrary code within the affected applications, compromising operational integrity and security.",Siemens,"Simatic S7-plcsim V16,Simatic S7-plcsim V17,Simatic Step 7 Safety V16,Simatic Step 7 Safety V17,Simatic Step 7 Safety V18,Simatic Step 7 Safety V19,Simatic Step 7 V16,Simatic Step 7 V17,Simatic Step 7 V18,Simatic Step 7 V19,Simatic Wincc Unified V16,Simatic Wincc Unified V17,Simatic Wincc Unified V18,Simatic Wincc Unified V19,Simatic Wincc V16,Simatic Wincc V17,Simatic Wincc V18,Simatic Wincc V19,Simocode Es V16,Simocode Es V17,Simocode Es V18,Simocode Es V19,Simotion Scout Tia V5.4 Sp1,Simotion Scout Tia V5.4 Sp3,Simotion Scout Tia V5.5 Sp1,Simotion Scout Tia V5.6 Sp1,Sinamics Startdrive V16,Sinamics Startdrive V17,Sinamics Startdrive V18,Sinamics Startdrive V19,Sirius Safety Es V17 (tia Portal),Sirius Safety Es V18 (tia Portal),Sirius Safety Es V19 (tia Portal),Sirius Soft Starter Es V17 (tia Portal),Sirius Soft Starter Es V18 (tia Portal),Sirius Soft Starter Es V19 (tia Portal),Tia Portal Cloud V16,Tia Portal Cloud V17,Tia Portal Cloud V18,Tia Portal Cloud V19",7.8,HIGH,0.0005300000193528831,false,,false,false,false,,false,false,2024-12-10T13:53:56.043Z,0 CVE-2023-32736,https://securityvulnerability.io/vulnerability/CVE-2023-32736,"{""Vulnerability in Siemens Products Could Allow Arbitrary Code Execution""}","A vulnerability exists in various Siemens automation products that fail to adequately sanitize user-controllable input, especially when processing user settings. This flaw could facilitate type confusion, potentially allowing an attacker to execute arbitrary code within the affected application. Affected software includes SIMATIC S7-PLCSIM, STEP 7, WinCC, and other associated tools, and users are advised to review the latest updates and apply necessary patches to mitigate this risk. For detailed information, refer to the provided reference.",Siemens,"Simatic S7-plcsim V16,Simatic S7-plcsim V17,Simatic Step 7 Safety V16,Simatic Step 7 Safety V17,Simatic Step 7 Safety V18,Simatic Step 7 V16,Simatic Step 7 V17,Simatic Step 7 V18,Simatic Wincc Unified V16,Simatic Wincc Unified V17,Simatic Wincc Unified V18,Simatic Wincc V16,Simatic Wincc V17,Simatic Wincc V18,Simocode Es V16,Simocode Es V17,Simocode Es V18,Simotion Scout Tia V5.4 Sp1,Simotion Scout Tia V5.4 Sp3,Simotion Scout Tia V5.5 Sp1,Sinamics Startdrive V16,Sinamics Startdrive V17,Sinamics Startdrive V18,Sirius Safety Es V17,Sirius Safety Es V18,Sirius Soft Starter Es V17,Sirius Soft Starter Es V18,Tia Portal Cloud V16,Tia Portal Cloud V17,Tia Portal Cloud V18",7.3,HIGH,0.0004299999854993075,false,,false,false,false,,false,false,2024-11-12T12:49:22.651Z,0 CVE-2023-32735,https://securityvulnerability.io/vulnerability/CVE-2023-32735,"{""Siemens: Multiple Products Affected by Deserialization Vulnerability"",""Siemens: Simatic Safety and Motion Control"",""Siemens: Sinamics Drive Technologies"",""Siemens: Simotion Safety"",""Siemens: TIA Portal Cloud""}","A vulnerability exists in various Siemens products, including SIMATIC STEP 7, SIMATIC WinCC, and other related applications, that fails to properly restrict .NET BinaryFormatter during the deserialization of hardware configuration profiles. This imperfection may lead to type confusion, enabling an attacker to execute arbitrary code within affected applications. This could result in unauthorized actions or data manipulation, posing a significant risk to system integrity and operations.",Siemens,"Simatic Step 7 Safety V16,Simatic Step 7 Safety V17,Simatic Step 7 Safety V18,Simatic Step 7 V16,Simatic Step 7 V17,Simatic Step 7 V18,Simatic Wincc Unified V16,Simatic Wincc Unified V17,Simatic Wincc Unified V18,Simatic Wincc V16,Simatic Wincc V17,Simatic Wincc V18,Simocode Es V16,Simocode Es V17,Simocode Es V18,Simotion Scout Tia V5.4 Sp1,Simotion Scout Tia V5.4 Sp3,Simotion Scout Tia V5.5 Sp1,Sinamics Startdrive V16,Sinamics Startdrive V17,Sinamics Startdrive V18,Sirius Safety Es V17,Sirius Safety Es V18,Sirius Soft Starter Es V17,Sirius Soft Starter Es V18,Soft Starter Es V16,Tia Portal Cloud V3.0",6.5,MEDIUM,0.0004299999854993075,false,,false,false,false,,false,false,2024-07-09T12:04:26.871Z,0 CVE-2023-27465,https://securityvulnerability.io/vulnerability/CVE-2023-27465,Debug Access Vulnerability in Siemens SIMOTION Products,"A security vulnerability has been discovered in various Siemens SIMOTION products that, when configured with a low security level, compromises access controls. Specifically, this flaw does not adequately secure certain services vital for debugging, enabling an unauthenticated attacker to retrieve sensitive technology object configurations from the affected devices. This raises significant security concerns for operational environments utilizing these systems.",Siemens,"SIMOTION C240,SIMOTION C240 PN,SIMOTION D410-2 DP,SIMOTION D410-2 DP/PN,SIMOTION D425-2 DP,SIMOTION D425-2 DP/PN,SIMOTION D435-2 DP,SIMOTION D435-2 DP/PN,SIMOTION D445-2 DP/PN,SIMOTION D455-2 DP/PN,SIMOTION P320-4 E,SIMOTION P320-4 S",4.6,MEDIUM,0.0005200000014156103,false,,false,false,false,,false,false,2023-06-13T09:15:00.000Z,0 CVE-2021-31890,https://securityvulnerability.io/vulnerability/CVE-2021-31890,,"A vulnerability has been identified in Capital Embedded AR Classic 431-422 (All versions), Capital Embedded AR Classic R20-11 (All versions < V2303), PLUSCONTROL 1st Gen (All versions), SIMOTICS CONNECT 400 (All versions < V0.5.0.0), SIMOTICS CONNECT 400 (All versions < V1.0.0.0). The total length of an TCP payload (set in the IP header) is unchecked. This may lead to various side effects, including Information Leak and Denial-of-Service conditions, depending on the network buffer organization in memory. (FSMD-2021-0017)",Siemens,"Capital Embedded Ar Classic 431-422,Capital Embedded Ar Classic R20-11,Pluscontrol 1st Gen,Simotics Connect 400",9.1,CRITICAL,0.012029999867081642,false,,false,false,false,,false,false,2021-11-09T11:32:02.000Z,0 CVE-2021-31889,https://securityvulnerability.io/vulnerability/CVE-2021-31889,,"A vulnerability has been identified in Capital Embedded AR Classic 431-422 (All versions), Capital Embedded AR Classic R20-11 (All versions < V2303), PLUSCONTROL 1st Gen (All versions), SIMOTICS CONNECT 400 (All versions < V0.5.0.0). Malformed TCP packets with a corrupted SACK option leads to Information Leaks and Denial-of-Service conditions. (FSMD-2021-0015)",Siemens,"Capital Embedded Ar Classic 431-422,Capital Embedded Ar Classic R20-11,Pluscontrol 1st Gen,Simotics Connect 400",9.1,CRITICAL,0.012029999867081642,false,,false,false,false,,false,false,2021-11-09T11:32:01.000Z,0 CVE-2021-31346,https://securityvulnerability.io/vulnerability/CVE-2021-31346,,"A vulnerability has been identified in Capital Embedded AR Classic 431-422 (All versions), Capital Embedded AR Classic R20-11 (All versions < V2303), PLUSCONTROL 1st Gen (All versions), SIMOTICS CONNECT 400 (All versions < V0.5.0.0), SIMOTICS CONNECT 400 (All versions < V1.0.0.0). The total length of an ICMP payload (set in the IP header) is unchecked. This may lead to various side effects, including Information Leak and Denial-of-Service conditions, depending on the network buffer organization in memory. (FSMD-2021-0007)",Siemens,"Capital Embedded Ar Classic 431-422,Capital Embedded Ar Classic R20-11,Pluscontrol 1st Gen,Simotics Connect 400",9.1,CRITICAL,0.012029999867081642,false,,false,false,false,,false,false,2021-11-09T11:31:53.000Z,0 CVE-2021-31344,https://securityvulnerability.io/vulnerability/CVE-2021-31344,,"A vulnerability has been identified in Capital Embedded AR Classic 431-422 (All versions), Capital Embedded AR Classic R20-11 (All versions < V2303), PLUSCONTROL 1st Gen (All versions), SIMOTICS CONNECT 400 (All versions < V0.5.0.0), SIMOTICS CONNECT 400 (All versions < V1.0.0.0). ICMP echo packets with fake IP options allow sending ICMP echo reply messages to arbitrary hosts on the network. (FSMD-2021-0004)",Siemens,"Capital Embedded Ar Classic 431-422,Capital Embedded Ar Classic R20-11,Pluscontrol 1st Gen,Simotics Connect 400",5.3,MEDIUM,0.005319999996572733,false,,false,false,false,,false,false,2021-11-09T11:31:51.000Z,0 CVE-2021-25677,https://securityvulnerability.io/vulnerability/CVE-2021-25677,,"A vulnerability has been identified in APOGEE PXC Compact (BACnet) (All versions < V3.5.5), APOGEE PXC Compact (P2 Ethernet) (All versions < V2.8.20), APOGEE PXC Modular (BACnet) (All versions < V3.5.5), APOGEE PXC Modular (P2 Ethernet) (All versions < V2.8.20), Nucleus NET (All versions), Nucleus ReadyStart V3 (All versions < V2017.02.3), Nucleus ReadyStart V3 (All versions < V2017.02.4), Nucleus ReadyStart V4 (All versions < V4.1.0), Nucleus Source Code (Versions including affected DNS modules), SIMOTICS CONNECT 400 (All versions < V0.5.0.0), SIMOTICS CONNECT 400 (All versions >= V0.5.0.0 < V1.0.0.0), TALON TC Compact (BACnet) (All versions < V3.5.5), TALON TC Modular (BACnet) (All versions < V3.5.5). The DNS client does not properly randomize DNS transaction IDs. That could allow an attacker to poison the DNS cache or spoof DNS resolving.",Siemens,"Apogee Pxc Compact (bacnet),Apogee Pxc Compact (p2 Ethernet),Apogee Pxc Modular (bacnet),Apogee Pxc Modular (p2 Ethernet),Nucleus Net,Nucleus Readystart V3,Nucleus Readystart V4,Nucleus Source Code,Simotics Connect 400,Talon Tc Compact (bacnet),Talon Tc Modular (bacnet)",5.3,MEDIUM,0.0010499999625608325,false,,false,false,false,,false,false,2021-04-22T20:42:21.000Z,0 CVE-2020-27738,https://securityvulnerability.io/vulnerability/CVE-2020-27738,,"A vulnerability has been identified in APOGEE PXC Compact (BACnet) (All versions < V3.5.5), APOGEE PXC Compact (P2 Ethernet) (All versions < V2.8.20), APOGEE PXC Modular (BACnet) (All versions < V3.5.5), APOGEE PXC Modular (P2 Ethernet) (All versions < V2.8.20), Nucleus NET (All versions), Nucleus ReadyStart V3 (All versions < V2017.02.3), Nucleus ReadyStart V4 (All versions < V4.1.0), Nucleus Source Code (Versions including affected DNS modules), SIMOTICS CONNECT 400 (All versions < V0.5.0.0), TALON TC Compact (BACnet) (All versions < V3.5.5), TALON TC Modular (BACnet) (All versions < V3.5.5). The DNS domain name record decompression functionality does not properly validate the pointer offset values. The parsing of malformed responses could result in a read access past the end of an allocated structure. An attacker with a privileged position in the network could leverage this vulnerability to cause a denial-of-service condition.",Siemens,"Apogee Pxc Compact (bacnet),Apogee Pxc Compact (p2 Ethernet),Apogee Pxc Modular (bacnet),Apogee Pxc Modular (p2 Ethernet),Nucleus Net,Nucleus Readystart V3,Nucleus Readystart V4,Nucleus Source Code,Simotics Connect 400,Talon Tc Compact (bacnet),Talon Tc Modular (bacnet)",6.5,MEDIUM,0.0028800000436604023,false,,false,false,false,,false,false,2021-04-22T20:42:20.000Z,0 CVE-2020-27737,https://securityvulnerability.io/vulnerability/CVE-2020-27737,,"A vulnerability has been identified in APOGEE PXC Compact (BACnet) (All versions < V3.5.5), APOGEE PXC Compact (P2 Ethernet) (All versions < V2.8.20), APOGEE PXC Modular (BACnet) (All versions < V3.5.5), APOGEE PXC Modular (P2 Ethernet) (All versions < V2.8.20), Nucleus NET (All versions), Nucleus ReadyStart V3 (All versions < V2017.02.3), Nucleus ReadyStart V4 (All versions < V4.1.0), Nucleus Source Code (Versions including affected DNS modules), SIMOTICS CONNECT 400 (All versions < V0.5.0.0), TALON TC Compact (BACnet) (All versions < V3.5.5), TALON TC Modular (BACnet) (All versions < V3.5.5). The DNS response parsing functionality does not properly validate various length and counts of the records. The parsing of malformed responses could result in a read past the end of an allocated structure. An attacker with a privileged position in the network could leverage this vulnerability to cause a denial-of-service condition or leak the memory past the allocated structure.",Siemens,"Apogee Pxc Compact (bacnet),Apogee Pxc Compact (p2 Ethernet),Apogee Pxc Modular (bacnet),Apogee Pxc Modular (p2 Ethernet),Nucleus Net,Nucleus Readystart V3,Nucleus Readystart V4,Nucleus Source Code,Simotics Connect 400,Talon Tc Compact (bacnet),Talon Tc Modular (bacnet)",6.5,MEDIUM,0.0016700000269338489,false,,false,false,false,,false,false,2021-04-22T20:42:19.000Z,0 CVE-2020-27736,https://securityvulnerability.io/vulnerability/CVE-2020-27736,,"A vulnerability has been identified in APOGEE PXC Compact (BACnet) (All versions < V3.5.5), APOGEE PXC Compact (P2 Ethernet) (All versions < V2.8.20), APOGEE PXC Modular (BACnet) (All versions < V3.5.5), APOGEE PXC Modular (P2 Ethernet) (All versions < V2.8.20), Nucleus NET (All versions), Nucleus ReadyStart V3 (All versions < V2017.02.3), Nucleus ReadyStart V4 (All versions < V4.1.0), Nucleus Source Code (Versions including affected DNS modules), SIMOTICS CONNECT 400 (All versions < V0.5.0.0), TALON TC Compact (BACnet) (All versions < V3.5.5), TALON TC Modular (BACnet) (All versions < V3.5.5). The DNS domain name label parsing functionality does not properly validate the null-terminated name in DNS-responses. The parsing of malformed responses could result in a read past the end of an allocated structure. An attacker with a privileged position in the network could leverage this vulnerability to cause a denial-of-service condition or leak the read memory.",Siemens,"Apogee Pxc Compact (bacnet),Apogee Pxc Compact (p2 Ethernet),Apogee Pxc Modular (bacnet),Apogee Pxc Modular (p2 Ethernet),Nucleus Net,Nucleus Readystart V3,Nucleus Readystart V4,Nucleus Source Code,Simotics Connect 400,Talon Tc Compact (bacnet),Talon Tc Modular (bacnet)",6.5,MEDIUM,0.0016700000269338489,false,,false,false,false,,false,false,2021-04-22T20:42:19.000Z,0 CVE-2019-13946,https://securityvulnerability.io/vulnerability/CVE-2019-13946,,"Profinet-IO (PNIO) stack versions prior V06.00 do not properly limit internal resource allocation when multiple legitimate diagnostic package requests are sent to the DCE-RPC interface. This could lead to a denial of service condition due to lack of memory for devices that include a vulnerable version of the stack. The security vulnerability could be exploited by an attacker with network access to an affected device. Successful exploitation requires no system privileges and no user interaction. An attacker could use the vulnerability to compromise the availability of the device.",Siemens,"Development/evaluation Kits For Profinet Io: Dk Standard Ethernet Controller,Development/evaluation Kits For Profinet Io: Ek-ertec 200,Development/evaluation Kits For Profinet Io: Ek-ertec 200p,Profinet Driver For Controller,Ruggedcom Rm1224 Family,Scalance M804pb,Scalance M812-1 Adsl-router,Scalance M816-1 Adsl-router,Scalance M826-2 Shdsl-router,Scalance M874-2,Scalance M874-3,Scalance M876-3,Scalance M876-3 (rok),Scalance M876-4 (eu),Scalance M876-4 (nam),Scalance S615 Lan-router,Scalance W-700 Ieee 802.11n Family,Scalance X200-4p Irt,Scalance X201-3p Irt,Scalance X201-3p Irt Pro,Scalance X202-2irt,Scalance X202-2p Irt,Scalance X202-2p Irt Pro,Scalance X204-2,Scalance X204-2fm,Scalance X204-2ld,Scalance X204-2ld Ts,Scalance X204-2ts,Scalance X204irt,Scalance X204irt Pro,Scalance X206-1,Scalance X206-1ld,Scalance X208,Scalance X208pro,Scalance X212-2,Scalance X212-2ld,Scalance X216,Scalance X224,Scalance X302-7 Eec (230v, Coated),Scalance X302-7 Eec (230v),Scalance X302-7 Eec (24v, Coated),Scalance X302-7 Eec (24v),Scalance X302-7 Eec (2x 230v, Coated),Scalance X302-7 Eec (2x 230v),Scalance X302-7 Eec (2x 24v, Coated),Scalance X302-7 Eec (2x 24v),Scalance X304-2fe,Scalance X306-1ld Fe,Scalance X307-2 Eec (230v, Coated),Scalance X307-2 Eec (230v),Scalance X307-2 Eec (24v, Coated),Scalance X307-2 Eec (24v),Scalance X307-2 Eec (2x 230v, Coated),Scalance X307-2 Eec (2x 230v),Scalance X307-2 Eec (2x 24v, Coated),Scalance X307-2 Eec (2x 24v),Scalance X307-3,Scalance X307-3ld,Scalance X308-2,Scalance X308-2ld,Scalance X308-2lh,Scalance X308-2lh+,Scalance X308-2m,Scalance X308-2m Poe,Scalance X308-2m Ts,Scalance X310,Scalance X310fe,Scalance X320-1 Fe,Scalance X320-1-2ld Fe,Scalance X408-2,Scalance Xb-200 Family,Scalance Xc-200,Scalance Xf-200ba,Scalance Xf201-3p Irt,Scalance Xf202-2p Irt,Scalance Xf204,Scalance Xf204-2,Scalance Xf204-2ba Irt,Scalance Xf204irt,Scalance Xf206-1,Scalance Xf208,Scalance Xm-400 Family,Scalance Xp-200,Scalance Xr-300wg Family,Scalance Xr-500 Family,Scalance Xr324-12m (230v, Ports On Front),Scalance Xr324-12m (230v, Ports On Rear),Scalance Xr324-12m (24v, Ports On Front),Scalance Xr324-12m (24v, Ports On Rear),Scalance Xr324-12m Ts (24v),Scalance Xr324-4m Eec (100-240vac/60-250vdc, Ports On Front),Scalance Xr324-4m Eec (100-240vac/60-250vdc, Ports On Rear),Scalance Xr324-4m Eec (24v, Ports On Front),Scalance Xr324-4m Eec (24v, Ports On Rear),Scalance Xr324-4m Eec (2x 100-240vac/60-250vdc, Ports On Front),Scalance Xr324-4m Eec (2x 100-240vac/60-250vdc, Ports On Rear),Scalance Xr324-4m Eec (2x 24v, Ports On Front),Scalance Xr324-4m Eec (2x 24v, Ports On Rear),Scalance Xr324-4m Poe (230v, Ports On Front),Scalance Xr324-4m Poe (230v, Ports On Rear),Scalance Xr324-4m Poe (24v, Ports On Front),Scalance Xr324-4m Poe (24v, Ports On Rear),Scalance Xr324-4m Poe Ts (24v, Ports On Front),Simatic Cp 1616 And Cp 1604,Simatic Cp 343-1,Simatic Cp 343-1 Advanced,Simatic Cp 343-1 Erpc,Simatic Cp 343-1 Lean,Simatic Cp 443-1,Simatic Cp 443-1 Advanced,Simatic Cp 443-1 Opc Ua,Simatic Et 200al Im 157-1 Pn,Simatic Et 200m Im 153-4 Pn Io Hf (incl. Siplus Variants),Simatic Et 200m Im 153-4 Pn Io St (incl. Siplus Variants),Simatic Et 200mp Im 155-5 Pn Hf,Simatic Et 200mp Im 155-5 Pn St,Simatic Et 200pro Im 154-3 Pn Hf,Simatic Et 200pro Im 154-4 Pn Hf,Simatic Et 200sp Im 155-6 Pn Ba,Simatic Et 200sp Im 155-6 Pn Hf,Simatic Et 200sp Im 155-6 Pn St,Simatic Et 200sp Im 155-6 Pn St Ba,Simatic Et200ecopn, 16di, Dc24v, 8xm12,Simatic Et200ecopn, 16do Dc24v/1,3a, 8xm12,Simatic Et200ecopn, 4ao U/i 4xm12,Simatic Et200ecopn, 8 Dio, Dc24v/1,3a, 8xm12,Simatic Et200ecopn, 8 Do, Dc24v/2a, 8xm12,Simatic Et200ecopn, 8ai Rtd/tc 8xm12,Simatic Et200ecopn, 8ai; 4 U/i; 4 Rtd/tc 8xm12,Simatic Et200ecopn, 8di, Dc24v, 4xm12,Simatic Et200ecopn, 8di, Dc24v, 8xm12,Simatic Et200ecopn, 8do, Dc24v/0,5a, 4xm12,Simatic Et200ecopn, 8do, Dc24v/1,3a, 4xm12,Simatic Et200ecopn, 8do, Dc24v/1,3a, 8xm12,Simatic Et200ecopn: Io-link Master,Simatic Et200s (incl. Siplus Variants),Simatic Ipc Support, Package For Vxworks,Simatic Mv420 Sr-b,Simatic Mv420 Sr-b Body,Simatic Mv420 Sr-p,Simatic Mv420 Sr-p Body,Simatic Mv440 Hr,Simatic Mv440 Sr,Simatic Mv440 Ur,Simatic Pn/pn Coupler (incl. Siplus Net Variants),Simatic Rf180c,Simatic Rf182c,Simatic Rf600r Family,Simotion C,Simotion D,Simotion P,Sinamics Dcp,Siplus Et 200mp Im 155-5 Pn Hf,Siplus Et 200mp Im 155-5 Pn Hf T1 Rail,Siplus Et 200mp Im 155-5 Pn St,Siplus Et 200mp Im 155-5 Pn St Tx Rail,Siplus Et 200sp Im 155-6 Pn Hf,Siplus Et 200sp Im 155-6 Pn Hf T1 Rail,Siplus Et 200sp Im 155-6 Pn St,Siplus Et 200sp Im 155-6 Pn St Ba,Siplus Et 200sp Im 155-6 Pn St Ba Tx Rail,Siplus Et 200sp Im 155-6 Pn St Tx Rail,Siplus Net Cp 343-1,Siplus Net Cp 343-1 Advanced,Siplus Net Cp 343-1 Lean,Siplus Net Cp 443-1,Siplus Net Cp 443-1 Advanced,Siplus Net Scalance X308-2,Softnet-ie Pnio",7.5,HIGH,0.0012000000569969416,false,,false,false,false,,false,false,2020-02-11T15:36:10.000Z,0 CVE-2019-13939,https://securityvulnerability.io/vulnerability/CVE-2019-13939,,"A vulnerability has been identified in APOGEE MEC/MBC/PXC (P2) (All versions < V2.8.2), APOGEE PXC Series (BACnet) (All versions < V3.5.3), APOGEE PXC Series (P2) (All versions >= V2.8.2 and < V2.8.19), Desigo PXC00-E.D (All versions >= V2.3x and < V6.00.327), Desigo PXC00-U (All versions >= V2.3x and < V6.00.327), Desigo PXC001-E.D (All versions >= V2.3x and < V6.00.327), Desigo PXC100-E.D (All versions >= V2.3x and < V6.00.327), Desigo PXC12-E.D (All versions >= V2.3x and < V6.00.327), Desigo PXC128-U (All versions >= V2.3x and < V6.00.327), Desigo PXC200-E.D (All versions >= V2.3x and < V6.00.327), Desigo PXC22-E.D (All versions >= V2.3x and < V6.00.327), Desigo PXC22.1-E.D (All versions >= V2.3x and < V6.00.327), Desigo PXC36.1-E.D (All versions >= V2.3x and < V6.00.327), Desigo PXC50-E.D (All versions >= V2.3x and < V6.00.327), Desigo PXC64-U (All versions >= V2.3x and < V6.00.327), Desigo PXM20-E (All versions >= V2.3x and < V6.00.327), Nucleus NET (All versions), Nucleus RTOS (All versions), Nucleus ReadyStart for ARM, MIPS, and PPC (All versions < V2017.02.2 with patch ""Nucleus 2017.02.02 Nucleus NET Patch""), Nucleus SafetyCert (All versions), Nucleus Source Code (All versions), SIMOTICS CONNECT 400 (All versions < V0.3.0.330), TALON TC Series (BACnet) (All versions < V3.5.3), VSTAR (All versions). By sending specially crafted DHCP packets to a device where the DHCP client is enabled, an attacker could change the IP address of the device to an invalid value. The vulnerability could affect availability and integrity of the device. Adjacent network access is required, but no authentication and no user interaction is needed to conduct an attack.",Siemens,"Apogee Mec/mbc/pxc (p2),Apogee Pxc Series (bacnet),Apogee Pxc Series (p2),Desigo Pxc00-e.d,Desigo Pxc00-u,Desigo Pxc001-e.d,Desigo Pxc100-e.d,Desigo Pxc12-e.d,Desigo Pxc128-u,Desigo Pxc200-e.d,Desigo Pxc22-e.d,Desigo Pxc22.1-e.d,Desigo Pxc36.1-e.d,Desigo Pxc50-e.d,Desigo Pxc64-u,Desigo Pxm20-e,Nucleus Net,Nucleus Rtos,Nucleus Readystart For Arm, Mips, And Ppc,Nucleus Safetycert,Nucleus Source Code,Simotics Connect 400,Talon Tc Series (bacnet),Vstar",7.1,HIGH,0.002259999979287386,false,,false,false,false,,false,false,2020-01-16T15:35:24.000Z,0 CVE-2019-10923,https://securityvulnerability.io/vulnerability/CVE-2019-10923,,An attacker with network access to an affected product may cause a denial of service condition by breaking the real-time synchronization (IRT) of the affected installation.,Siemens,"Development/evaluation Kits For Profinet Io: Dk Standard Ethernet Controller,Development/evaluation Kits For Profinet Io: Ek-ertec 200,Development/evaluation Kits For Profinet Io: Ek-ertec 200p,Scalance X-200irt Family (incl. Siplus Net Variants),Simatic Et 200m (incl. Siplus Variants),Simatic Et 200mp Im 155-5 Pn Hf,Simatic Et 200mp Im 155-5 Pn St,Simatic Et 200pro Im 154-3 Pn Hf,Simatic Et 200pro Im 154-4 Pn Hf,Simatic Et 200pro Im 154-8 Pn/dp Cpu,Simatic Et 200pro Im 154-8f Pn/dp Cpu,Simatic Et 200pro Im 154-8fx Pn/dp Cpu,Simatic Et 200s Im 151-8 Pn/dp Cpu,Simatic Et 200s Im 151-8f Pn/dp Cpu,Simatic Et 200sp Im 155-6 Pn Hf,Simatic Et 200sp Im 155-6 Pn St,Simatic Et 200sp Im 155-6 Pn St Ba,Simatic Et200ecopn, 16di, Dc24v, 8xm12,Simatic Et200ecopn, 16do Dc24v/1,3a, 8xm12,Simatic Et200ecopn, 4ao U/i 4xm12,Simatic Et200ecopn, 8 Dio, Dc24v/1,3a, 8xm12,Simatic Et200ecopn, 8 Do, Dc24v/2a, 8xm12,Simatic Et200ecopn, 8ai Rtd/tc 8xm12,Simatic Et200ecopn, 8ai; 4 U/i; 4 Rtd/tc 8xm12,Simatic Et200ecopn, 8di, Dc24v, 4xm12,Simatic Et200ecopn, 8di, Dc24v, 8xm12,Simatic Et200ecopn, 8do, Dc24v/0,5a, 4xm12,Simatic Et200ecopn, 8do, Dc24v/1,3a, 4xm12,Simatic Et200ecopn, 8do, Dc24v/1,3a, 8xm12,Simatic Et200ecopn: Io-link Master,Simatic Et200s (incl. Siplus Variants),Simatic Net Cp 1604,Simatic Net Cp 1616,Simatic Pn/pn Coupler (incl. Siplus Net Variants),Simatic S7-300 Cpu 314c-2 Pn/dp,Simatic S7-300 Cpu 315-2 Pn/dp,Simatic S7-300 Cpu 315f-2 Pn/dp,Simatic S7-300 Cpu 315t-3 Pn/dp,Simatic S7-300 Cpu 317-2 Pn/dp,Simatic S7-300 Cpu 317f-2 Pn/dp,Simatic S7-300 Cpu 317t-3 Pn/dp,Simatic S7-300 Cpu 317tf-3 Pn/dp,Simatic S7-300 Cpu 319-3 Pn/dp,Simatic S7-300 Cpu 319f-3 Pn/dp,Simatic S7-400 Cpu 412-2 Pn V7,Simatic S7-400 Cpu 414-3 Pn/dp V7,Simatic S7-400 Cpu 414f-3 Pn/dp V7,Simatic S7-400 Cpu 416-3 Pn/dp V7,Simatic S7-400 Cpu 416f-3 Pn/dp V7,Simatic S7-400 Pn/dp V6 And Below Cpu Family (incl. Siplus Variants),Simatic Winac Rtx 2010,Simatic Winac Rtx F 2010,Simotion,Sinamics Dcm,Sinamics Dcp,Sinamics G110m V4.7 Control Unit,Sinamics G120 V4.7 Control Unit (incl. Siplus Variants),Sinamics G130 V4.7 Control Unit,Sinamics G150 Control Unit,Sinamics Gh150 V4.7 Control Unit,Sinamics Gl150 V4.7 Control Unit,Sinamics Gm150 V4.7 Control Unit,Sinamics S110 Control Unit,Sinamics S120 V4.7 Control Unit And Cbe20 (incl. Siplus Variants),Sinamics S150 Control Unit,Sinamics Sl150 V4.7 Control Unit,Sinamics Sm120 V4.7 Control Unit,Sinumerik 828d,Sinumerik 840d Sl,Siplus Et 200mp Im 155-5 Pn Hf,Siplus Et 200mp Im 155-5 Pn Hf T1 Rail,Siplus Et 200mp Im 155-5 Pn St,Siplus Et 200mp Im 155-5 Pn St Tx Rail,Siplus Et 200s Im 151-8 Pn/dp Cpu,Siplus Et 200s Im 151-8f Pn/dp Cpu,Siplus Et 200sp Im 155-6 Pn Hf,Siplus Et 200sp Im 155-6 Pn Hf T1 Rail,Siplus Et 200sp Im 155-6 Pn St,Siplus Et 200sp Im 155-6 Pn St Ba,Siplus Et 200sp Im 155-6 Pn St Ba Tx Rail,Siplus Et 200sp Im 155-6 Pn St Tx Rail,Siplus S7-300 Cpu 314c-2 Pn/dp,Siplus S7-300 Cpu 315-2 Pn/dp,Siplus S7-300 Cpu 315f-2 Pn/dp,Siplus S7-300 Cpu 317-2 Pn/dp,Siplus S7-300 Cpu 317f-2 Pn/dp,Siplus S7-400 Cpu 414-3 Pn/dp V7,Siplus S7-400 Cpu 416-3 Pn/dp V7",7.5,HIGH,0.0012000000569969416,false,,false,false,false,,false,false,2019-10-10T13:49:24.000Z,0 CVE-2017-12741,https://securityvulnerability.io/vulnerability/CVE-2017-12741,,Specially crafted packets sent to port 161/udp could cause a denial of service condition. The affected devices must be restarted manually.,Siemens,"Development/evaluation Kits For Profinet Io: Dk Standard Ethernet Controller,Development/evaluation Kits For Profinet Io: Ek-ertec 200,Development/evaluation Kits For Profinet Io: Ek-ertec 200p,Simatic Compact Field Unit,Simatic Et 200al Im 157-1 Pn,Simatic Et 200m (incl. Siplus Variants),Simatic Et 200mp Im 155-5 Pn Ba,Simatic Et 200mp Im 155-5 Pn Hf,Simatic Et 200mp Im 155-5 Pn St,Simatic Et 200pro Im 154-3 Pn Hf,Simatic Et 200pro Im 154-4 Pn Hf,Simatic Et 200sp Im 155-6 Pn Ba,Simatic Et 200sp Im 155-6 Pn Ha (incl. Siplus Variants),Simatic Et 200sp Im 155-6 Pn Hf,Simatic Et 200sp Im 155-6 Pn Hs,Simatic Et 200sp Im 155-6 Pn St,Simatic Et 200sp Im 155-6 Pn St Ba,Simatic Et200ecopn, 16di, Dc24v, 8xm12,Simatic Et200ecopn, 16do Dc24v/1,3a, 8xm12,Simatic Et200ecopn, 4ao U/i 4xm12,Simatic Et200ecopn, 8 Dio, Dc24v/1,3a, 8xm12,Simatic Et200ecopn, 8 Do, Dc24v/2a, 8xm12,Simatic Et200ecopn, 8ai Rtd/tc 8xm12,Simatic Et200ecopn, 8ai; 4 U/i; 4 Rtd/tc 8xm12,Simatic Et200ecopn, 8di, Dc24v, 4xm12,Simatic Et200ecopn, 8di, Dc24v, 8xm12,Simatic Et200ecopn, 8do, Dc24v/0,5a, 4xm12,Simatic Et200ecopn, 8do, Dc24v/1,3a, 4xm12,Simatic Et200ecopn, 8do, Dc24v/1,3a, 8xm12,Simatic Et200ecopn: Io-link Master,Simatic Et200s (incl. Siplus Variants),Simatic Pn/pn Coupler (incl. Siplus Net Variants),Simatic S7-1200 Cpu Family (incl. Siplus Variants),Simatic S7-1500 Cpu Family (incl. Related Et200 Cpus And Siplus Variants),Simatic S7-1500 Software Controller,Simatic S7-200 Smart,Simatic S7-300 Cpu Family (incl. Related Et200 Cpus And Siplus Variants),Simatic S7-400 H V6 and Below cpu Family (incl. Siplus Variants),Simatic S7-400 Pn/dp V6 And Below Cpu Family (incl. Siplus Variants),Simatic S7-400 Pn/dp V7 Cpu Family (incl. Siplus Variants),Simatic S7-410 V8 Cpu Family (incl. Siplus Variants),Simatic Tdc Cp51m1,Simatic Tdc Cpu555,Simatic Winac Rtx 2010,Simatic Winac Rtx F 2010,Simocode Pro V Profinet (incl. Siplus Variants),Simotion C,Simotion D,Simotion D4xx V4.4 For Sinamics Sm150i-2 W. Profinet (incl. Siplus Variants),Simotion P V4.4 And V4.5,Simotion P V5,Sinamics Dcm W. Pn,Sinamics Dcp W. Pn,Sinamics G110m W. Pn,Sinamics G120(c/p/d) W. Pn (incl. Siplus Variants),Sinamics G130 V4.7 W. Pn,Sinamics G130 V4.8 W. Pn,Sinamics G150 V4.7 W. Pn,Sinamics G150 V4.8 W. Pn,Sinamics Gh150 V4.7 W. Profinet,Sinamics Gl150 V4.7 W. Profinet,Sinamics Gm150 V4.7 W. Profinet,Sinamics S110 W. Pn,Sinamics S120 Prior To V4.7 W. Pn (incl. Siplus Variants),Sinamics S120 V4.7 Sp1 W. Pn (incl. Siplus Variants),Sinamics S120 V4.7 W. Pn (incl. Siplus Variants),Sinamics S120 V4.8 W. Pn (incl. Siplus Variants),Sinamics S150 V4.7 W. Pn,Sinamics S150 V4.8 W. Pn,Sinamics Sl150 V4.7.0 W. Profinet,Sinamics Sl150 V4.7.4 W. Profinet,Sinamics Sl150 V4.7.5 W. Profinet,Sinamics Sm120 V4.7 W. Profinet,Sinamics V90 W. Pn,Sinumerik 840d Sl,Siplus Et 200mp Im 155-5 Pn Hf,Siplus Et 200mp Im 155-5 Pn Hf T1 Rail,Siplus Et 200mp Im 155-5 Pn St,Siplus Et 200mp Im 155-5 Pn St Tx Rail,Siplus Et 200sp Im 155-6 Pn Hf,Siplus Et 200sp Im 155-6 Pn Hf T1 Rail,Siplus Et 200sp Im 155-6 Pn St,Siplus Et 200sp Im 155-6 Pn St Ba,Siplus Et 200sp Im 155-6 Pn St Ba Tx Rail,Siplus Et 200sp Im 155-6 Pn St Tx Rail,Sirius Soft Starter 3rw44 Pn",7.5,HIGH,0.004639999940991402,false,,false,false,false,,false,false,2017-12-26T04:00:00.000Z,0 CVE-2017-2681,https://securityvulnerability.io/vulnerability/CVE-2017-2681,,Specially crafted PROFINET DCP packets sent on a local Ethernet segment (Layer 2) to an affected product could cause a denial of service condition of that product. Human interaction is required to recover the system. PROFIBUS interfaces are not affected.,Siemens,"Development/evaluation Kits For Profinet Io: Dk Standard Ethernet Controller,Development/evaluation Kits For Profinet Io: Ek-ertec 200,Development/evaluation Kits For Profinet Io: Ek-ertec 200p,Ie/as-i Link Pn Io,Ie/pb-link (incl. Siplus Net Variants),Scalance M-800 Family (incl. S615, Mum-800 And Rm1224),Scalance W-700 Ieee 802.11n Family,Scalance X-200 Family (incl. Siplus Net Variants),Scalance X-200irt Family (incl. Siplus Net Variants),Scalance X-300 Family (incl. X408 And Siplus Net Variants),Scalance X408 Family,Scalance X414,Scalance Xm-400 Family,Scalance Xr-500 Family,Simatic Cm 1542-1,Simatic Cm 1542sp-1,Simatic Cp 1243-1 (incl. Siplus Variants),Simatic Cp 1243-1 Dnp3 (incl. Siplus Variants),Simatic Cp 1243-1 Iec (incl. Siplus Variants),Simatic Cp 1243-8 Irc,Simatic Cp 1542sp-1 Irc (incl. Siplus Variants),Simatic Cp 1543-1 (incl. Siplus Variants),Simatic Cp 1543sp-1 (incl. Siplus Variants),Simatic Cp 1604,Simatic Cp 1616,Simatic Cp 343-1 (incl. Siplus Variants),Simatic Cp 343-1 Advanced (incl. Siplus Variants),Simatic Cp 343-1 Lean (incl. Siplus Variants),Simatic Cp 443-1 (incl. Siplus Variants),Simatic Cp 443-1 Advanced (incl. Siplus Variants),Simatic Cp 443-1 Opc Ua,Simatic Dk-16xx Pn Io,Simatic Et 200al Im 157-1 Pn,Simatic Et 200m (incl. Siplus Variants),Simatic Et 200mp Im 155-5 Pn Ba,Simatic Et 200mp Im 155-5 Pn Hf,Simatic Et 200mp Im 155-5 Pn St,Simatic Et 200pro Im 154-3 Pn Hf,Simatic Et 200pro Im 154-4 Pn Hf,Simatic Et 200sp Im 155-6 Pn Ba,Simatic Et 200sp Im 155-6 Pn Hf,Simatic Et 200sp Im 155-6 Pn Hs,Simatic Et 200sp Im 155-6 Pn St,Simatic Et 200sp Im 155-6 Pn St Ba,Simatic Et200ecopn, 16di, Dc24v, 8xm12,Simatic Et200ecopn, 16do Dc24v/1,3a, 8xm12,Simatic Et200ecopn, 4ao U/i 4xm12,Simatic Et200ecopn, 8 Dio, Dc24v/1,3a, 8xm12,Simatic Et200ecopn, 8 Do, Dc24v/2a, 8xm12,Simatic Et200ecopn, 8ai Rtd/tc 8xm12,Simatic Et200ecopn, 8ai; 4 U/i; 4 Rtd/tc 8xm12,Simatic Et200ecopn, 8di, Dc24v, 4xm12,Simatic Et200ecopn, 8di, Dc24v, 8xm12,Simatic Et200ecopn, 8do, Dc24v/0,5a, 4xm12,Simatic Et200ecopn, 8do, Dc24v/1,3a, 4xm12,Simatic Et200ecopn, 8do, Dc24v/1,3a, 8xm12,Simatic Et200ecopn: Io-link Master,Simatic Et200s (incl. Siplus Variants),Simatic Hmi Comfort Panels, Hmi Multi Panels, Hmi Mobile Panels (incl. Siplus Variants),Simatic Mv420 Sr-b,Simatic Mv420 Sr-b Body,Simatic Mv420 Sr-p,Simatic Mv420 Sr-p Body,Simatic Mv440 Hr,Simatic Mv440 Sr,Simatic Mv440 Ur,Simatic Pn/pn Coupler (incl. Siplus Net Variants),Simatic Rf650r,Simatic Rf680r,Simatic Rf685r,Simatic S7-1200 Cpu Family (incl. Siplus Variants),Simatic S7-1500 Cpu Family (incl. Related Et200 Cpus And Siplus Variants),Simatic S7-1500 Software Controller,Simatic S7-200 Smart,Simatic S7-300 Cpu Family (incl. Related Et200 Cpus And Siplus Variants),Simatic S7-400 H V6 Cpu Family (incl. Siplus Variants),Simatic S7-400 Pn/dp V6 Cpu Family (incl. Siplus Variants),Simatic S7-400 Pn/dp V7 Cpu Family (incl. Siplus Variants),Simatic S7-410 Cpu Family (incl. Siplus Variants),Simatic Tdc Cp51m1,Simatic Tdc Cpu555,Simatic Teleservice Adapter Ie Advanced,Simatic Teleservice Adapter Ie Basic,Simatic Teleservice Adapter Ie Standard,Simatic Winac Rtx 2010,Simatic Winac Rtx F 2010,Simocode Pro V Profinet (incl. Siplus Variants),Simotion,Sinamics Dcm W. Pn,Sinamics Dcp W. Pn,Sinamics G110m W. Pn,Sinamics G120(c/p/d) W. Pn (incl. Siplus Variants),Sinamics G130 V4.7 W. Pn,Sinamics G130 V4.8 W. Pn,Sinamics G150 V4.7 W. Pn,Sinamics G150 V4.8 W. Pn,Sinamics S110 W. Pn,Sinamics S120 Prior To V4.7 W. Pn (incl. Siplus Variants),Sinamics S120 V4.7 Sp1 W. Pn (incl. Siplus Variants),Sinamics S120 V4.7 W. Pn (incl. Siplus Variants),Sinamics S120 V4.8 W. Pn (incl. Siplus Variants),Sinamics S150 V4.7 W. Pn,Sinamics S150 V4.8 W. Pn,Sinamics V90 W. Pn,Sinumerik 828d V4.5 And Prior,Sinumerik 828d V4.7,Sinumerik 840d Sl V4.5 And Prior,Sinumerik 840d Sl V4.7,Siplus Et 200mp Im 155-5 Pn Hf,Siplus Et 200mp Im 155-5 Pn Hf T1 Rail,Siplus Et 200mp Im 155-5 Pn St,Siplus Et 200mp Im 155-5 Pn St Tx Rail,Siplus Et 200sp Im 155-6 Pn Hf,Siplus Et 200sp Im 155-6 Pn Hf T1 Rail,Siplus Et 200sp Im 155-6 Pn St,Siplus Et 200sp Im 155-6 Pn St Ba,Siplus Et 200sp Im 155-6 Pn St Ba Tx Rail,Siplus Et 200sp Im 155-6 Pn St Tx Rail,Sirius Act 3su1 Interface Module Profinet,Sirius Motor Starter M200d Profinet,Sirius Soft Starter 3rw44 Pn,Sitop Psu8600 Profinet,Sitop Ups1600 Profinet (incl. Siplus Variants),Softnet Profinet Io For Pc-based Windows Systems",6.5,MEDIUM,0.0019399999873712659,false,,false,false,false,,false,false,2017-05-11T10:00:00.000Z,0 CVE-2017-2680,https://securityvulnerability.io/vulnerability/CVE-2017-2680,,Specially crafted PROFINET DCP broadcast packets could cause a denial of service condition of affected products on a local Ethernet segment (Layer 2). Human interaction is required to recover the systems. PROFIBUS interfaces are not affected.,Siemens,"Development/evaluation Kits For Profinet Io: Dk Standard Ethernet Controller,Development/evaluation Kits For Profinet Io: Ek-ertec 200,Development/evaluation Kits For Profinet Io: Ek-ertec 200p,Extension Unit 12"" Profinet,Extension Unit 15"" Profinet,Extension Unit 19"" Profinet,Extension Unit 22"" Profinet,Ie/as-i Link Pn Io,Ie/pb-link (incl. Siplus Net Variants),Scalance M-800 Family (incl. S615, Mum-800 And Rm1224),Scalance W-700 Ieee 802.11n Family,Scalance X-200 Family (incl. Siplus Net Variants),Scalance X-200irt Family (incl. Siplus Net Variants),Scalance X-300 Family (incl. X408 And Siplus Net Variants),Scalance X408 Family,Scalance X414,Scalance Xm-400 Family,Scalance Xr-500 Family,Simatic Cm 1542-1,Simatic Cm 1542sp-1,Simatic Cp 1242-7 V2 (incl. Siplus Variants),Simatic Cp 1243-1 (incl. Siplus Variants),Simatic Cp 1243-1 Dnp3 (incl. Siplus Variants),Simatic Cp 1243-1 Iec (incl. Siplus Variants),Simatic Cp 1243-7 Lte Us,Simatic Cp 1243-8 Irc,Simatic Cp 1542sp-1 Irc (incl. Siplus Variants),Simatic Cp 1543-1 (incl. Siplus Variants),Simatic Cp 1543sp-1 (incl. Siplus Variants),Simatic Cp 1604,Simatic Cp 1616,Simatic Cp 1626,Simatic Cp 343-1 (incl. Siplus Variants),Simatic Cp 343-1 Advanced (incl. Siplus Variants),Simatic Cp 343-1 Lean (incl. Siplus Variants),Simatic Cp 443-1 (incl. Siplus Variants),Simatic Cp 443-1 Advanced (incl. Siplus Variants),Simatic Cp 443-1 Opc Ua,Simatic Dk-16xx Pn Io,Simatic Et 200al Im 157-1 Pn,Simatic Et 200m (incl. Siplus Variants),Simatic Et 200mp Im 155-5 Pn Ba,Simatic Et 200mp Im 155-5 Pn Hf,Simatic Et 200mp Im 155-5 Pn St,Simatic Et 200pro Im 154-3 Pn Hf,Simatic Et 200pro Im 154-4 Pn Hf,Simatic Et 200sp Im 155-6 Pn Ba,Simatic Et 200sp Im 155-6 Pn Hf,Simatic Et 200sp Im 155-6 Pn Hs,Simatic Et 200sp Im 155-6 Pn St,Simatic Et 200sp Im 155-6 Pn St Ba,Simatic Et200ecopn, 16di, Dc24v, 8xm12,Simatic Et200ecopn, 16do Dc24v/1,3a, 8xm12,Simatic Et200ecopn, 4ao U/i 4xm12,Simatic Et200ecopn, 8 Dio, Dc24v/1,3a, 8xm12,Simatic Et200ecopn, 8 Do, Dc24v/2a, 8xm12,Simatic Et200ecopn, 8ai Rtd/tc 8xm12,Simatic Et200ecopn, 8ai; 4 U/i; 4 Rtd/tc 8xm12,Simatic Et200ecopn, 8di, Dc24v, 4xm12,Simatic Et200ecopn, 8di, Dc24v, 8xm12,Simatic Et200ecopn, 8do, Dc24v/0,5a, 4xm12,Simatic Et200ecopn, 8do, Dc24v/1,3a, 4xm12,Simatic Et200ecopn, 8do, Dc24v/1,3a, 8xm12,Simatic Et200ecopn: Io-link Master,Simatic Et200s (incl. Siplus Variants),Simatic Hmi Comfort Panels, Hmi Multi Panels, Hmi Mobile Panels (incl. Siplus Variants),Simatic Mv420 Sr-b,Simatic Mv420 Sr-b Body,Simatic Mv420 Sr-p,Simatic Mv420 Sr-p Body,Simatic Mv440 Hr,Simatic Mv440 Sr,Simatic Mv440 Ur,Simatic Pn/pn Coupler (incl. Siplus Net Variants),Simatic Rf650r,Simatic Rf680r,Simatic Rf685r,Simatic S7-1200 Cpu Family (incl. Siplus Variants),Simatic S7-1500 Cpu Family (incl. Related Et200 Cpus And Siplus Variants),Simatic S7-1500 Software Controller,Simatic S7-200 Smart,Simatic S7-300 Cpu Family (incl. Related Et200 Cpus And Siplus Variants),Simatic S7-400 H V6 Cpu Family (incl. Siplus Variants),Simatic S7-400 Pn/dp V6 Cpu Family (incl. Siplus Variants),Simatic S7-400 Pn/dp V7 Cpu Family (incl. Siplus Variants),Simatic S7-410 Cpu Family (incl. Siplus Variants),Simatic Tdc Cp51m1,Simatic Tdc Cpu555,Simatic Teleservice Adapter Ie Advanced,Simatic Teleservice Adapter Ie Basic,Simatic Teleservice Adapter Ie Standard,Simatic Winac Rtx 2010,Simatic Winac Rtx F 2010,Simocode Pro V Profinet (incl. Siplus Variants),Simotion,Simotion D4xx V4.4 For Sinamics Sm150i-2 W. Profinet (incl. Siplus Variants),Sinamics Dcm W. Pn,Sinamics Dcp W. Pn,Sinamics G110m W. Pn,Sinamics G120(c/p/d) W. Pn (incl. Siplus Variants),Sinamics G130 V4.7 W. Pn,Sinamics G130 V4.8 W. Pn,Sinamics G150 V4.7 W. Pn,Sinamics G150 V4.8 W. Pn,Sinamics Gh150 V4.7 W. Profinet,Sinamics Gl150 V4.7 W. Profinet,Sinamics Gm150 V4.7 W. Profinet,Sinamics S110 W. Pn,Sinamics S120 Prior To V4.7 W. Pn (incl. Siplus Variants),Sinamics S120 V4.7 Sp1 W. Pn (incl. Siplus Variants),Sinamics S120 V4.7 W. Pn (incl. Siplus Variants),Sinamics S120 V4.8 W. Pn (incl. Siplus Variants),Sinamics S150 V4.7 W. Pn,Sinamics S150 V4.8 W. Pn,Sinamics Sl150 V4.7.0 W. Profinet,Sinamics Sl150 V4.7.4 W. Profinet,Sinamics Sl150 V4.7.5 W. Profinet,Sinamics Sm120 V4.7 W. Profinet,Sinamics V90 W. Pn,Sinumerik 828d V4.5 And Prior,Sinumerik 828d V4.7,Sinumerik 840d Sl V4.5 And Prior,Sinumerik 840d Sl V4.7,Siplus Et 200mp Im 155-5 Pn Hf,Siplus Et 200mp Im 155-5 Pn Hf T1 Rail,Siplus Et 200mp Im 155-5 Pn St,Siplus Et 200mp Im 155-5 Pn St Tx Rail,Siplus Et 200sp Im 155-6 Pn Hf,Siplus Et 200sp Im 155-6 Pn Hf T1 Rail,Siplus Et 200sp Im 155-6 Pn St,Siplus Et 200sp Im 155-6 Pn St Ba,Siplus Et 200sp Im 155-6 Pn St Ba Tx Rail,Siplus Et 200sp Im 155-6 Pn St Tx Rail,Sirius Act 3su1 Interface Module Profinet,Sirius Motor Starter M200d Profinet,Sirius Soft Starter 3rw44 Pn,Sitop Psu8600 Profinet,Sitop Ups1600 Profinet (incl. Siplus Variants),Softnet Profinet Io For Pc-based Windows Systems",6.5,MEDIUM,0.0024999999441206455,false,,false,false,false,,false,false,2017-05-11T01:00:00.000Z,0