cve,link,title,description,vendor,products,score,severity,epss,cisa,cisa_published,article,ransomware,exploited,poc,trended,trended_no_1,published,trended_score CVE-2024-43781,https://securityvulnerability.io/vulnerability/CVE-2024-43781,Insertion of Sensitive Information into Log File Vulnerability Affects SINUMERIK Systems,"A vulnerability has been identified in SINUMERIK 828D V4 (All versions < V4.95 SP3), SINUMERIK 840D sl V4 (All versions < V4.95 SP3 in connection with using Create MyConfig (CMC) <= V4.8 SP1 HF6), SINUMERIK ONE (All versions < V6.23 in connection with using Create MyConfig (CMC) <= V6.6), SINUMERIK ONE (All versions < V6.15 SP4 in connection with using Create MyConfig (CMC) <= V6.6). Affected systems, that have been provisioned with Create MyConfig (CMC), contain a Insertion of Sensitive Information into Log File vulnerability. This could allow a local authenticated user with low privileges to read sensitive information and thus circumvent access restrictions.",Siemens,"Sinumerik 828d V4,Sinumerik 840d Sl V4,Sinumerik One",5.5,MEDIUM,0.0004299999854993075,false,,false,false,false,,false,false,2024-09-10T09:36:51.143Z,0 CVE-2024-41171,https://securityvulnerability.io/vulnerability/CVE-2024-41171,SINUMERIK Devices Vulnerable to Privilege Escalation Attacks,"A vulnerability has been identified in various Siemens SINUMERIK products where access restrictions to scripts executed with elevated privileges are not properly enforced. This flaw affects devices including SINUMERIK 828D, SINUMERIK 840D sl, and SINUMERIK ONE, allowing an authenticated local attacker to escalate privileges, potentially leading to unauthorized control over the system. The issue exists across all versions of SINUMERIK 828D V4 and 840D sl V4, as well as versions of SINUMERIK ONE prior to V6.24, thus posing risks to operational integrity. For more information, visit the official Siemens CERT portal.",Siemens,"Sinumerik 828d V4,Sinumerik 828d V5,Sinumerik 840d Sl V4,Sinumerik One",8.8,HIGH,0.0004299999854993075,false,,false,false,false,,false,false,2024-09-10T09:36:46.244Z,0 CVE-2023-46280,https://securityvulnerability.io/vulnerability/CVE-2023-46280,Out of Bounds Read Vulnerability in SIMATIC and TIA Portal Products by Siemens,"An out of bounds read vulnerability has been identified in multiple Siemens products, including the SIMATIC and TIA Portal series. This flaw can potentially lead to the crashing of the Windows kernel, resulting in a Blue Screen of Death (BSOD) error. Attackers could exploit this vulnerability to destabilize systems, impacting operational efficiency and safety within industrial environments. It is crucial for users of these products to be aware of this vulnerability and to implement necessary mitigations as outlined by Siemens.",Siemens,"Security Configuration Tool (sct),Simatic Automation Tool,Simatic Batch V9.1,Simatic Net Pc Software V16,Simatic Net Pc Software V17,Simatic Net Pc Software V18,Simatic Net Pc Software V19,Simatic Pcs 7 V9.1,Simatic Pdm V9.2,Simatic Route Control V9.1,Simatic S7-pct,Simatic Step 7 V5,Simatic Wincc Oa V3.17,Simatic Wincc Oa V3.18,Simatic Wincc Oa V3.19,Simatic Wincc Runtime Advanced,Simatic Wincc Runtime Professional V16,Simatic Wincc Runtime Professional V17,Simatic Wincc Runtime Professional V18,Simatic Wincc Runtime Professional V19,Simatic Wincc V7.4,Simatic Wincc V7.5,Simatic Wincc V8.0,Sinamics Startdrive,Sinec Nms,Sinumerik One Virtual,Sinumerik Plc Programming Tool,Tia Portal Cloud Connector,Totally Integrated Automation Portal (tia Portal) V15.1,Totally Integrated Automation Portal (tia Portal) V16,Totally Integrated Automation Portal (tia Portal) V17,Totally Integrated Automation Portal (tia Portal) V18,Totally Integrated Automation Portal (tia Portal) V19",6.5,MEDIUM,0.00044999999227002263,false,,false,false,false,,false,false,2024-05-14T10:01:52.069Z,0 CVE-2023-46156,https://securityvulnerability.io/vulnerability/CVE-2023-46156,Denial of Service Vulnerability in Siemens Products,"Certain Siemens devices are vulnerable due to improper handling of specially crafted packets sent to TCP port 102. This loophole allows attackers to induce a denial of service condition, causing normal operations to cease. To restore functionality, a device restart is necessary.",Siemens,"Simatic Drive Controller Cpu 1504d Tf,Simatic Drive Controller Cpu 1507d Tf,Simatic Et 200sp Open Controller Cpu 1515sp Pc2 (incl. Siplus Variants),Simatic S7-1500 Cpu 1510sp F-1 Pn,Simatic S7-1500 Cpu 1510sp-1 Pn,Simatic S7-1500 Cpu 1511-1 Pn,Simatic S7-1500 Cpu 1511c-1 Pn,Simatic S7-1500 Cpu 1511f-1 Pn,Simatic S7-1500 Cpu 1511t-1 Pn,Simatic S7-1500 Cpu 1511tf-1 Pn,Simatic S7-1500 Cpu 1512c-1 Pn,Simatic S7-1500 Cpu 1512sp F-1 Pn,Simatic S7-1500 Cpu 1512sp-1 Pn,Simatic S7-1500 Cpu 1513-1 Pn,Simatic S7-1500 Cpu 1513f-1 Pn,Simatic S7-1500 Cpu 1513r-1 Pn,Simatic S7-1500 Cpu 1514sp F-2 Pn,Simatic S7-1500 Cpu 1514sp-2 Pn,Simatic S7-1500 Cpu 1514spt F-2 Pn,Simatic S7-1500 Cpu 1514spt-2 Pn,Simatic S7-1500 Cpu 1515-2 Pn,Simatic S7-1500 Cpu 1515f-2 Pn,Simatic S7-1500 Cpu 1515r-2 Pn,Simatic S7-1500 Cpu 1515t-2 Pn,Simatic S7-1500 Cpu 1515tf-2 Pn,Simatic S7-1500 Cpu 1516-3 Pn/dp,Simatic S7-1500 Cpu 1516f-3 Pn/dp,Simatic S7-1500 Cpu 1516t-3 Pn/dp,Simatic S7-1500 Cpu 1516tf-3 Pn/dp,Simatic S7-1500 Cpu 1517-3 Pn/dp,Simatic S7-1500 Cpu 1517f-3 Pn/dp,Simatic S7-1500 Cpu 1517h-3 Pn,Simatic S7-1500 Cpu 1517t-3 Pn/dp,Simatic S7-1500 Cpu 1517tf-3 Pn/dp,Simatic S7-1500 Cpu 1518-4 Pn/dp,Simatic S7-1500 Cpu 1518-4 Pn/dp Mfp,Simatic S7-1500 Cpu 1518f-4 Pn/dp,Simatic S7-1500 Cpu 1518f-4 Pn/dp Mfp,Simatic S7-1500 Cpu 1518hf-4 Pn,Simatic S7-1500 Cpu 1518t-4 Pn/dp,Simatic S7-1500 Cpu 1518tf-4 Pn/dp,Simatic S7-1500 Cpu S7-1518-4 Pn/dp Odk,Simatic S7-1500 Cpu S7-1518f-4 Pn/dp Odk,Simatic S7-1500 Et 200pro: Cpu 1513pro F-2 Pn,Simatic S7-1500 Et 200pro: Cpu 1513pro-2 Pn,Simatic S7-1500 Et 200pro: Cpu 1516pro F-2 Pn,Simatic S7-1500 Et 200pro: Cpu 1516pro-2 Pn,Simatic S7-1500 Software Controller,Simatic S7-plcsim Advanced,Sinumerik Mc,Sinumerik One,Siplus Et 200sp Cpu 1510sp F-1 Pn,Siplus Et 200sp Cpu 1510sp F-1 Pn Rail,Siplus Et 200sp Cpu 1510sp-1 Pn,Siplus Et 200sp Cpu 1510sp-1 Pn Rail,Siplus Et 200sp Cpu 1512sp F-1 Pn,Siplus Et 200sp Cpu 1512sp F-1 Pn Rail,Siplus Et 200sp Cpu 1512sp-1 Pn,Siplus Et 200sp Cpu 1512sp-1 Pn Rail,Siplus S7-1500 Cpu 1511-1 Pn,Siplus S7-1500 Cpu 1511-1 Pn T1 Rail,Siplus S7-1500 Cpu 1511-1 Pn Tx Rail,Siplus S7-1500 Cpu 1511f-1 Pn,Siplus S7-1500 Cpu 1513-1 Pn,Siplus S7-1500 Cpu 1513f-1 Pn,Siplus S7-1500 Cpu 1515f-2 Pn,Siplus S7-1500 Cpu 1515f-2 Pn Rail,Siplus S7-1500 Cpu 1515f-2 Pn T2 Rail,Siplus S7-1500 Cpu 1515r-2 Pn,Siplus S7-1500 Cpu 1515r-2 Pn Tx Rail,Siplus S7-1500 Cpu 1516-3 Pn/dp,Siplus S7-1500 Cpu 1516-3 Pn/dp Rail,Siplus S7-1500 Cpu 1516-3 Pn/dp Tx Rail,Siplus S7-1500 Cpu 1516f-3 Pn/dp,Siplus S7-1500 Cpu 1516f-3 Pn/dp Rail,Siplus S7-1500 Cpu 1517h-3 Pn,Siplus S7-1500 Cpu 1518-4 Pn/dp,Siplus S7-1500 Cpu 1518-4 Pn/dp Mfp,Siplus S7-1500 Cpu 1518f-4 Pn/dp,Siplus S7-1500 Cpu 1518hf-4 Pn",7.5,HIGH,0.00044999999227002263,false,,false,false,false,,false,false,2023-12-12T12:15:00.000Z,0 CVE-2023-28831,https://securityvulnerability.io/vulnerability/CVE-2023-28831,Integer Overflow Issue in Siemens OPC UA Implementations,"The OPC UA implementations in Siemens products harbor an integer overflow vulnerability that can lead to an infinite loop during the certificate validation process. This condition could be exploited by an unauthenticated remote attacker utilizing a specially crafted certificate, resulting in a denial of service that impacts application availability and reliability.",Siemens,"Simatic Braumat,Simatic Cloud Connect 7 Cc712,Simatic Cloud Connect 7 Cc716,Simatic Comfort/mobile Rt,Simatic Drive Controller Cpu 1504d Tf,Simatic Drive Controller Cpu 1507d Tf,Simatic Et 200sp Open Controller Cpu 1515sp Pc2 (incl. Siplus Variants),Simatic Ipc Diagmonitor,Simatic Net Pc Software V14,Simatic Net Pc Software V16,Simatic Net Pc Software V17,Simatic Net Pc Software V18,Simatic Pcs 7 V9.1,Simatic Pcs Neo V4.0,Simatic S7-1500 Cpu 1510sp F-1 Pn,Simatic S7-1500 Cpu 1510sp-1 Pn,Simatic S7-1500 Cpu 1511-1 Pn,Simatic S7-1500 Cpu 1511c-1 Pn,Simatic S7-1500 Cpu 1511f-1 Pn,Simatic S7-1500 Cpu 1511t-1 Pn,Simatic S7-1500 Cpu 1511tf-1 Pn,Simatic S7-1500 Cpu 1512c-1 Pn,Simatic S7-1500 Cpu 1512sp F-1 Pn,Simatic S7-1500 Cpu 1512sp-1 Pn,Simatic S7-1500 Cpu 1513-1 Pn,Simatic S7-1500 Cpu 1513f-1 Pn,Simatic S7-1500 Cpu 1514sp F-2 Pn,Simatic S7-1500 Cpu 1514sp-2 Pn,Simatic S7-1500 Cpu 1514spt F-2 Pn,Simatic S7-1500 Cpu 1514spt-2 Pn,Simatic S7-1500 Cpu 1515-2 Pn,Simatic S7-1500 Cpu 1515f-2 Pn,Simatic S7-1500 Cpu 1515t-2 Pn,Simatic S7-1500 Cpu 1515tf-2 Pn,Simatic S7-1500 Cpu 1516-3 Pn/dp,Simatic S7-1500 Cpu 1516f-3 Pn/dp,Simatic S7-1500 Cpu 1516t-3 Pn/dp,Simatic S7-1500 Cpu 1516tf-3 Pn/dp,Simatic S7-1500 Cpu 1517-3 Pn/dp,Simatic S7-1500 Cpu 1517f-3 Pn/dp,Simatic S7-1500 Cpu 1517t-3 Pn/dp,Simatic S7-1500 Cpu 1517tf-3 Pn/dp,Simatic S7-1500 Cpu 1518-4 Pn/dp,Simatic S7-1500 Cpu 1518-4 Pn/dp Mfp,Simatic S7-1500 Cpu 1518f-4 Pn/dp,Simatic S7-1500 Cpu 1518f-4 Pn/dp Mfp,Simatic S7-1500 Cpu 1518t-4 Pn/dp,Simatic S7-1500 Cpu 1518tf-4 Pn/dp,Simatic S7-1500 Cpu S7-1518-4 Pn/dp Odk,Simatic S7-1500 Cpu S7-1518f-4 Pn/dp Odk,Simatic S7-1500 Et 200pro: Cpu 1513pro F-2 Pn,Simatic S7-1500 Et 200pro: Cpu 1513pro-2 Pn,Simatic S7-1500 Et 200pro: Cpu 1516pro F-2 Pn,Simatic S7-1500 Et 200pro: Cpu 1516pro-2 Pn,Simatic S7-1500 Software Controller V2,Simatic S7-1500 Software Controller V3,Simatic S7-plcsim Advanced,Simatic Sistar,Simatic Wincc Oa V3.17,Simatic Wincc Oa V3.18,Simatic Wincc Oa V3.19,Simatic Wincc Opc Ua Client,Simatic Wincc Runtime Professional V16,Simatic Wincc Runtime Professional V17,Simatic Wincc Runtime Professional V18,Simatic Wincc Runtime Professional V19,Simatic Wincc Unified Opc Ua Server,Simatic Wincc V7.4,Simatic Wincc V7.5,Simatic Wincc V8.0,Sinumerik Mc,Sinumerik One,Siplus Et 200sp Cpu 1510sp F-1 Pn,Siplus Et 200sp Cpu 1510sp F-1 Pn Rail,Siplus Et 200sp Cpu 1510sp-1 Pn,Siplus Et 200sp Cpu 1510sp-1 Pn Rail,Siplus Et 200sp Cpu 1512sp F-1 Pn,Siplus Et 200sp Cpu 1512sp F-1 Pn Rail,Siplus Et 200sp Cpu 1512sp-1 Pn,Siplus Et 200sp Cpu 1512sp-1 Pn Rail,Siplus S7-1500 Cpu 1511-1 Pn,Siplus S7-1500 Cpu 1511-1 Pn T1 Rail,Siplus S7-1500 Cpu 1511-1 Pn Tx Rail,Siplus S7-1500 Cpu 1511f-1 Pn,Siplus S7-1500 Cpu 1513-1 Pn,Siplus S7-1500 Cpu 1513f-1 Pn,Siplus S7-1500 Cpu 1515f-2 Pn,Siplus S7-1500 Cpu 1515f-2 Pn Rail,Siplus S7-1500 Cpu 1515f-2 Pn T2 Rail,Siplus S7-1500 Cpu 1516-3 Pn/dp,Siplus S7-1500 Cpu 1516-3 Pn/dp Rail,Siplus S7-1500 Cpu 1516-3 Pn/dp Tx Rail,Siplus S7-1500 Cpu 1516f-3 Pn/dp,Siplus S7-1500 Cpu 1516f-3 Pn/dp Rail,Siplus S7-1500 Cpu 1518-4 Pn/dp,Siplus S7-1500 Cpu 1518-4 Pn/dp Mfp,Siplus S7-1500 Cpu 1518f-4 Pn/dp",7.5,HIGH,0.0005300000193528831,false,,false,false,false,,false,false,2023-09-12T10:15:00.000Z,0 CVE-2022-30694,https://securityvulnerability.io/vulnerability/CVE-2022-30694,Cross-Site Request Forgery Vulnerability in Siemens Web Services,"An issue in the login endpoint of Siemens web services permits inadequate origin checking, allowing authenticated remote attackers to potentially exploit this weakness. By leveraging this vulnerability, attackers can orchestrate cross-site request forgery (CSRF) attacks, which could enable them to track the activities of legitimate users without their consent.",Siemens,"Simatic Drive Controller Cpu 1504d Tf,Simatic Drive Controller Cpu 1507d Tf,Simatic Et 200pro Im154-8 Pn/dp Cpu,Simatic Et 200pro Im154-8f Pn/dp Cpu,Simatic Et 200pro Im154-8fx Pn/dp Cpu,Simatic Et 200s Im151-8 Pn/dp Cpu,Simatic Et 200s Im151-8f Pn/dp Cpu,Simatic Et 200sp Open Controller Cpu 1515sp Pc2 (incl. Siplus Variants),Simatic Pc Station,Simatic S7-1200 Cpu Family (incl. Siplus Variants),Simatic S7-1500 Cpu 1510sp F-1 Pn,Simatic S7-1500 Cpu 1510sp-1 Pn,Simatic S7-1500 Cpu 1511-1 Pn,Simatic S7-1500 Cpu 1511c-1 Pn,Simatic S7-1500 Cpu 1511f-1 Pn,Simatic S7-1500 Cpu 1511t-1 Pn,Simatic S7-1500 Cpu 1511tf-1 Pn,Simatic S7-1500 Cpu 1512c-1 Pn,Simatic S7-1500 Cpu 1512sp F-1 Pn,Simatic S7-1500 Cpu 1512sp-1 Pn,Simatic S7-1500 Cpu 1513-1 Pn,Simatic S7-1500 Cpu 1513f-1 Pn,Simatic S7-1500 Cpu 1513r-1 Pn,Simatic S7-1500 Cpu 1515-2 Pn,Simatic S7-1500 Cpu 1515f-2 Pn,Simatic S7-1500 Cpu 1515r-2 Pn,Simatic S7-1500 Cpu 1515t-2 Pn,Simatic S7-1500 Cpu 1515tf-2 Pn,Simatic S7-1500 Cpu 1516-3 Pn/dp,Simatic S7-1500 Cpu 1516f-3 Pn/dp,Simatic S7-1500 Cpu 1516t-3 Pn/dp,Simatic S7-1500 Cpu 1516tf-3 Pn/dp,Simatic S7-1500 Cpu 1517-3 Pn/dp,Simatic S7-1500 Cpu 1517f-3 Pn/dp,Simatic S7-1500 Cpu 1517h-3 Pn,Simatic S7-1500 Cpu 1517t-3 Pn/dp,Simatic S7-1500 Cpu 1517tf-3 Pn/dp,Simatic S7-1500 Cpu 1518-4 Pn/dp,Simatic S7-1500 Cpu 1518-4 Pn/dp Mfp,Simatic S7-1500 Cpu 1518f-4 Pn/dp,Simatic S7-1500 Cpu 1518f-4 Pn/dp Mfp,Simatic S7-1500 Cpu 1518hf-4 Pn,Simatic S7-1500 Cpu 1518t-4 Pn/dp,Simatic S7-1500 Cpu 1518tf-4 Pn/dp,Simatic S7-1500 Cpu S7-1518-4 Pn/dp Odk,Simatic S7-1500 Cpu S7-1518f-4 Pn/dp Odk,Simatic S7-1500 Et 200pro: Cpu 1513pro F-2 Pn,Simatic S7-1500 Et 200pro: Cpu 1513pro-2 Pn,Simatic S7-1500 Et 200pro: Cpu 1516pro F-2 Pn,Simatic S7-1500 Et 200pro: Cpu 1516pro-2 Pn,Simatic S7-1500 Software Controller V2,Simatic S7-300 Cpu 314c-2 Pn/dp,Simatic S7-300 Cpu 315-2 Pn/dp,Simatic S7-300 Cpu 315f-2 Pn/dp,Simatic S7-300 Cpu 315t-3 Pn/dp,Simatic S7-300 Cpu 317-2 Pn/dp,Simatic S7-300 Cpu 317f-2 Pn/dp,Simatic S7-300 Cpu 317t-3 Pn/dp,Simatic S7-300 Cpu 317tf-3 Pn/dp,Simatic S7-300 Cpu 319-3 Pn/dp,Simatic S7-300 Cpu 319f-3 Pn/dp,Simatic S7-400 Pn/dp V6 Cpu Family (incl. Siplus Variants),Simatic S7-400 Pn/dp V7 Cpu Family (incl. Siplus Variants),Simatic S7-plcsim Advanced,Simatic Wincc Runtime Advanced,Sinumerik One,Siplus Et 200s Im151-8 Pn/dp Cpu,Siplus Et 200s Im151-8f Pn/dp Cpu,Siplus Et 200sp Cpu 1510sp F-1 Pn,Siplus Et 200sp Cpu 1510sp F-1 Pn Rail,Siplus Et 200sp Cpu 1510sp-1 Pn,Siplus Et 200sp Cpu 1510sp-1 Pn Rail,Siplus Et 200sp Cpu 1512sp F-1 Pn,Siplus Et 200sp Cpu 1512sp F-1 Pn Rail,Siplus Et 200sp Cpu 1512sp-1 Pn,Siplus Et 200sp Cpu 1512sp-1 Pn Rail,Siplus S7-1500 Cpu 1511-1 Pn,Siplus S7-1500 Cpu 1511-1 Pn T1 Rail,Siplus S7-1500 Cpu 1511-1 Pn Tx Rail,Siplus S7-1500 Cpu 1511f-1 Pn,Siplus S7-1500 Cpu 1513-1 Pn,Siplus S7-1500 Cpu 1513f-1 Pn,Siplus S7-1500 Cpu 1515f-2 Pn,Siplus S7-1500 Cpu 1515f-2 Pn Rail,Siplus S7-1500 Cpu 1515f-2 Pn T2 Rail,Siplus S7-1500 Cpu 1515r-2 Pn,Siplus S7-1500 Cpu 1515r-2 Pn Tx Rail,Siplus S7-1500 Cpu 1516-3 Pn/dp,Siplus S7-1500 Cpu 1516-3 Pn/dp Rail,Siplus S7-1500 Cpu 1516-3 Pn/dp Tx Rail,Siplus S7-1500 Cpu 1516f-3 Pn/dp,Siplus S7-1500 Cpu 1516f-3 Pn/dp Rail,Siplus S7-1500 Cpu 1517h-3 Pn,Siplus S7-1500 Cpu 1518-4 Pn/dp,Siplus S7-1500 Cpu 1518-4 Pn/dp Mfp,Siplus S7-1500 Cpu 1518f-4 Pn/dp,Siplus S7-1500 Cpu 1518hf-4 Pn,Siplus S7-300 Cpu 314c-2 Pn/dp,Siplus S7-300 Cpu 315-2 Pn/dp,Siplus S7-300 Cpu 315f-2 Pn/dp,Siplus S7-300 Cpu 317-2 Pn/dp,Siplus S7-300 Cpu 317f-2 Pn/dp",6.5,MEDIUM,0.0004600000102072954,false,,false,false,false,,false,false,2022-11-08T00:00:00.000Z,0 CVE-2022-38465,https://securityvulnerability.io/vulnerability/CVE-2022-38465,Vulnerability in SIMATIC Drive Controllers and Related Products by Siemens,"A cryptographic vulnerability affects several product families within the Siemens SIMATIC range, most notably the SIMATIC Drive Controllers and various CPUs. The issue stems from inadequate protection of the built-in global private key, which is intended to secure sensitive configuration data and facilitate communications. This flaw permits potential offline attacks by enabling malicious actors to deduce the private key by exploiting a single compromised unit. Once obtained, the private key could lead to unauthorized access to confidential configuration data and disrupt legacy communications with PG/PC and HMI systems.",Siemens,"Simatic Drive Controller Family,Simatic Et 200sp Open Controller Cpu 1515sp Pc (incl. Siplus Variants),Simatic Et 200sp Open Controller Cpu 1515sp Pc2 (incl. Siplus Variants),Simatic S7-1200 Cpu Family (incl. Siplus Variants),Simatic S7-1500 Cpu Family (incl. Related Et200 Cpus And Siplus Variants),Simatic S7-1500 Software Controller,Simatic S7-plcsim Advanced,Sinumerik Mc,Sinumerik One",9.3,CRITICAL,0.0004400000034365803,false,,false,false,false,,false,false,2022-10-11T00:00:00.000Z,0 CVE-2022-24408,https://securityvulnerability.io/vulnerability/CVE-2022-24408,,"A vulnerability has been identified in SINUMERIK MC (All versions < V1.15 SP1), SINUMERIK ONE (All versions < V6.15 SP1). The sc SUID binary on affected devices provides several commands that are used to execute system commands or modify system files. A specific set of operations using sc could allow local attackers to escalate their privileges to root.",Siemens,"Sinumerik Mc,Sinumerik One",7.8,HIGH,0.0004199999966658652,false,,false,false,false,,false,false,2022-03-08T11:31:30.000Z,0 CVE-2020-15782,https://securityvulnerability.io/vulnerability/CVE-2020-15782,,"A vulnerability has been identified in SIMATIC Drive Controller family (All versions < V2.9.2), SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants) (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions < V21.9), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions < V4.5.0), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions < V2.9.2), SIMATIC S7-1500 Software Controller (All versions < V21.9), SIMATIC S7-PLCSIM Advanced (All versions < V4.0), SINAMICS PERFECT HARMONY GH180 Drives (Drives manufactured before 2021-08-13), SINUMERIK MC (All versions < V6.15), SINUMERIK ONE (All versions < V6.15). Affected devices are vulnerable to a memory protection bypass through a specific operation. A remote unauthenticated attacker with network access to port 102/tcp could potentially write arbitrary data and code to protected memory areas or read sensitive data to launch further attacks.",Siemens,"Simatic Drive Controller Family,Simatic Et 200sp Open Controller Cpu 1515sp Pc (incl. Siplus Variants),Simatic Et 200sp Open Controller Cpu 1515sp Pc2 (incl. Siplus Variants),Simatic S7-1200 Cpu Family (incl. Siplus Variants),Simatic S7-1500 Cpu Family (incl. Related Et200 Cpus And Siplus Variants),Simatic S7-1500 Software Controller,Simatic S7-plcsim Advanced,Sinamics Perfect Harmony Gh180 Drives,Sinumerik Mc,Sinumerik One",9.8,CRITICAL,0.004569999873638153,false,,false,false,false,,false,false,2021-05-28T16:10:10.000Z,0 CVE-2020-7580,https://securityvulnerability.io/vulnerability/CVE-2020-7580,,"A vulnerability has been identified in SIMATIC Automation Tool (All versions < V4 SP2), SIMATIC NET PC Software V14 (All versions < V14 SP1 Update 14), SIMATIC NET PC Software V15 (All versions), SIMATIC NET PC Software V16 (All versions < V16 Upd3), SIMATIC PCS neo (All versions < V3.0 SP1), SIMATIC ProSave (All versions < V17), SIMATIC S7-1500 Software Controller (All versions < V21.8), SIMATIC STEP 7 (TIA Portal) V13 (All versions < V13 SP2 Update 4), SIMATIC STEP 7 (TIA Portal) V14 (All versions < V14 SP1 Update 10), SIMATIC STEP 7 (TIA Portal) V15 (All versions < V15.1 Update 5), SIMATIC STEP 7 (TIA Portal) V16 (All versions < V16 Update 2), SIMATIC STEP 7 V5 (All versions < V5.6 SP2 HF3), SIMATIC WinCC OA V3.16 (All versions < V3.16 P018), SIMATIC WinCC OA V3.17 (All versions < V3.17 P003), SIMATIC WinCC Runtime Advanced (All versions < V16 Update 2), SIMATIC WinCC Runtime Professional V13 (All versions < V13 SP2 Update 4), SIMATIC WinCC Runtime Professional V14 (All versions < V14 SP1 Update 10), SIMATIC WinCC Runtime Professional V15 (All versions < V15.1 Update 5), SIMATIC WinCC Runtime Professional V16 (All versions < V16 Update 2), SIMATIC WinCC V7.4 (All versions < V7.4 SP1 Update 14), SIMATIC WinCC V7.5 (All versions < V7.5 SP1 Update 3), SINAMICS STARTER (All Versions < V5.4 HF2), SINAMICS Startdrive (All Versions < V16 Update 3), SINEC NMS (All versions < V1.0 SP2), SINEMA Server (All versions < V14 SP3), SINUMERIK ONE virtual (All Versions < V6.14), SINUMERIK Operate (All Versions < V6.14). A common component used by the affected applications regularly calls a helper binary with SYSTEM privileges while the call path is not quoted. This could allow a local attacker to execute arbitrary code with SYTEM privileges.",Siemens,"Simatic Automation Tool,Simatic Net Pc Software V14,Simatic Net Pc Software V15,Simatic Net Pc Software V16,Simatic Pcs Neo,Simatic Prosave,Simatic S7-1500 Software Controller,Simatic Step 7 (tia Portal) V13,Simatic Step 7 (tia Portal) V14,Simatic Step 7 (tia Portal) V15,Simatic Step 7 (tia Portal) V16,Simatic Step 7 V5,Simatic Wincc Oa V3.16,Simatic Wincc Oa V3.17,Simatic Wincc Runtime Advanced,Simatic Wincc Runtime Professional V13,Simatic Wincc Runtime Professional V14,Simatic Wincc Runtime Professional V15,Simatic Wincc Runtime Professional V16,Simatic Wincc V7.4,Simatic Wincc V7.5,Sinamics Starter,Sinamics Startdrive,Sinec Nms,Sinema Server,Sinumerik One Virtual,Sinumerik Operate",6.7,MEDIUM,0.0004600000102072954,false,,false,false,false,,false,false,2020-06-10T00:00:00.000Z,0