cve,link,title,description,vendor,products,score,severity,epss,cisa,cisa_published,article,ransomware,exploited,poc,trended,trended_no_1,published,trended_score CVE-2018-16563,https://securityvulnerability.io/vulnerability/CVE-2018-16563,,"A vulnerability has been identified in Firmware variant IEC 61850 for EN100 Ethernet module (All versions < V4.35), Firmware variant MODBUS TCP for EN100 Ethernet module (All versions), Firmware variant DNP3 TCP for EN100 Ethernet module (All versions), Firmware variant IEC104 for EN100 Ethernet module (All versions), Firmware variant Profinet IO for EN100 Ethernet module (All versions), SIPROTEC 5 relays with CPU variants CP300 and CP100 and the respective Ethernet communication modules (All versions < V7.82), SIPROTEC 5 relays with CPU variants CP200 and the respective Ethernet communication modules (All versions < V7.58). Specially crafted packets to port 102/tcp could cause a denial-of-service condition in the affected products. A manual restart is required to recover the EN100 module functionality of the affected devices. Successful exploitation requires an attacker with network access to send multiple packets to the affected products or modules. As a precondition the IEC 61850-MMS communication needs to be activated on the affected products or modules. No user interaction or privileges are required to exploit the vulnerability. The vulnerability could allow causing a Denial-of-Service condition of the network functionality of the device, compromising the availability of the system. At the time of advisory publication no public exploitation of this security vulnerability was known.",Siemens,"Firmware Variant Iec 61850 For En100 Ethernet Module,Firmware Variant Modbus Tcp For En100 Ethernet Module,Firmware Variant Dnp3 Tcp For En100 Ethernet Module,Firmware Variant Iec104 For En100 Ethernet Module,Firmware Variant Profinet Io For En100 Ethernet Module,Siprotec 5 Relays With Cpu Variants Cp300 And Cp100 And The Respective Ethernet Communication Modules,Siprotec 5 Relays With Cpu Variants Cp200 And The Respective Ethernet Communication Modules",5.9,MEDIUM,0.0010499999625608325,false,,false,false,false,,false,false,2019-03-21T14:57:36.000Z,0 CVE-2018-11451,https://securityvulnerability.io/vulnerability/CVE-2018-11451,,"A vulnerability has been identified in Firmware variant IEC 61850 for EN100 Ethernet module (All versions < V4.33), Firmware variant PROFINET IO for EN100 Ethernet module (All versions), Firmware variant Modbus TCP for EN100 Ethernet module (All versions), Firmware variant DNP3 TCP for EN100 Ethernet module (All versions), Firmware variant IEC104 for EN100 Ethernet module (All versions < V1.22), SIPROTEC 5 relays with CPU variants CP300 and CP100 and the respective Ethernet communication modules (All versions < V7.80), SIPROTEC 5 relays with CPU variants CP200 and the respective Ethernet communication modules (All versions < V7.58). Specially crafted packets to port 102/tcp could cause a denial-of-service condition in the affected products. A manual restart is required to recover the EN100 module functionality of the affected devices. Successful exploitation requires an attacker with network access to send multiple packets to the affected products or modules. As a precondition the IEC 61850-MMS communication needs to be activated on the affected products or modules. No user interaction or privileges are required to exploit the vulnerability. The vulnerability could allow causing a Denial-of-Service condition of the network functionality of the device, compromising the availability of the system. At the time of advisory publication no public exploitation of this security vulnerability was known.",Siemens,"Firmware Variant Iec 61850 For En100 Ethernet Module,Firmware Variant Profinet Io For En100 Ethernet Module,Firmware Variant Modbus Tcp For En100 Ethernet Module,Firmware Variant Dnp3 Tcp For En100 Ethernet Module,Firmware Variant Iec104 For En100 Ethernet Module,Siprotec 5 Relays With Cpu Variants Cp300 And Cp100 And The Respective Ethernet Communication Modules,Siprotec 5 Relays With Cpu Variants Cp200 And The Respective Ethernet Communication Modules",7.5,HIGH,0.002420000033453107,false,,false,false,false,,false,false,2018-07-23T21:00:00.000Z,0 CVE-2016-4785,https://securityvulnerability.io/vulnerability/CVE-2016-4785,,A vulnerability has been identified in Firmware variant PROFINET IO for EN100 Ethernet module : All versions < V1.04.01; Firmware variant Modbus TCP for EN100 Ethernet module : All versions < V1.11.00; Firmware variant DNP3 TCP for EN100 Ethernet module : All versions < V1.03; Firmware variant IEC 104 for EN100 Ethernet module : All versions < V1.21; EN100 Ethernet module included in SIPROTEC Merging Unit 6MU80 : All versions < 1.02.02. The integrated web server (port 80/tcp) of the affected devices could allow remote attackers to obtain a limited amount of device memory content if network access was obtained. This vulnerability only affects EN100 Ethernet module included in SIPROTEC4 and SIPROTEC Compact devices.,Siemens,Siprotec Firmware,5.3,MEDIUM,0.00394000019878149,false,,false,false,false,,false,false,2016-05-31T01:59:00.000Z,0 CVE-2016-4784,https://securityvulnerability.io/vulnerability/CVE-2016-4784,,A vulnerability has been identified in firmware variant PROFINET IO for EN100 Ethernet module : All versions < V1.04.01; Firmware variant Modbus TCP for EN100 Ethernet module : All versions < V1.11.00; Firmware variant DNP3 TCP for EN100 Ethernet module : All versions < V1.03; Firmware variant IEC 104 for EN100 Ethernet module : All versions < V1.21; EN100 Ethernet module included in SIPROTEC Merging Unit 6MU80 : All versions < 1.02.02; SIPROTEC 7SJ686 : All versions < V 4.83; SIPROTEC 7UT686 : All versions < V 4.01; SIPROTEC 7SD686 : All versions < V 4.03; SIPROTEC 7SJ66 : All versions < V 4.20. The integrated web server (port 80/tcp) of the affected devices could allow remote attackers to obtain sensitive device information if network access was obtained.,Siemens,Siprotec Firmware,5.3,MEDIUM,0.00394000019878149,false,,false,false,false,,false,false,2016-05-31T01:59:00.000Z,0 CVE-2015-5374,https://securityvulnerability.io/vulnerability/CVE-2015-5374,,A vulnerability has been identified in Firmware variant PROFINET IO for EN100 Ethernet module : All versions < V1.04.01; Firmware variant Modbus TCP for EN100 Ethernet module : All versions < V1.11.00; Firmware variant DNP3 TCP for EN100 Ethernet module : All versions < V1.03; Firmware variant IEC 104 for EN100 Ethernet module : All versions < V1.21; EN100 Ethernet module included in SIPROTEC Merging Unit 6MU80 : All versions < 1.02.02. Specially crafted packets sent to port 50000/UDP could cause a denial-of-service of the affected device. A manual reboot may be required to recover the service of the device.,Siemens,Siprotec Firmware,,,0.2024800032377243,false,,false,false,true,true,false,false,2015-07-18T10:59:00.000Z,0