cve,link,title,description,vendor,products,score,severity,epss,cisa,cisa_published,article,ransomware,exploited,poc,trended,trended_no_1,published,trended_score CVE-2020-7581,https://securityvulnerability.io/vulnerability/CVE-2020-7581,,"A vulnerability has been identified in Opcenter Execution Discrete (All versions < V3.2), Opcenter Execution Foundation (All versions < V3.2), Opcenter Execution Process (All versions < V3.2), Opcenter Intelligence (All versions < V3.3), Opcenter Quality (All versions < V11.3), Opcenter RD&L (V8.0), SIMATIC Notifier Server for Windows (All versions), SIMATIC PCS neo (All versions < V3.0 SP1), SIMATIC STEP 7 (TIA Portal) V15 (All versions < V15.1 Update 5), SIMATIC STEP 7 (TIA Portal) V16 (All versions < V16 Update 2), SIMOCODE ES V15.1 (All versions < V15.1 Update 4), SIMOCODE ES V16 (All versions < V16 Update 1), Soft Starter ES V15.1 (All versions < V15.1 Update 3), Soft Starter ES V16 (All versions < V16 Update 1). A component within the affected application calls a helper binary with SYSTEM privileges during startup while the call path is not quoted. This could allow a local attacker with administrative privileges to execute code with SYSTEM level privileges.",Siemens,"Opcenter Execution Discrete,Opcenter Execution Foundation,Opcenter Execution Process,Opcenter Intelligence,Opcenter Quality,Opcenter Rd&l,Simatic Notifier Server For Windows,Simatic Pcs Neo,Simatic Step 7 (tia Portal) V15,Simatic Step 7 (tia Portal) V16,Simocode Es V15.1,Simocode Es V16,Soft Starter Es V15.1,Soft Starter Es V16",6.7,MEDIUM,0.0004199999966658652,false,,false,false,false,,false,false,2020-07-14T13:18:05.000Z,0 CVE-2020-7588,https://securityvulnerability.io/vulnerability/CVE-2020-7588,,"A vulnerability has been identified in Opcenter Execution Discrete (All versions < V3.2), Opcenter Execution Foundation (All versions < V3.2), Opcenter Execution Process (All versions < V3.2), Opcenter Intelligence (All versions < V3.3), Opcenter Quality (All versions < V11.3), Opcenter RD&L (V8.0), SIMATIC IT LMS (All versions < V2.6), SIMATIC IT Production Suite (All versions < V8.0), SIMATIC Notifier Server for Windows (All versions), SIMATIC PCS neo (All versions < V3.0 SP1), SIMATIC STEP 7 (TIA Portal) V15 (All versions < V15.1 Update 5), SIMATIC STEP 7 (TIA Portal) V16 (All versions < V16 Update 2), SIMOCODE ES V15.1 (All versions < V15.1 Update 4), SIMOCODE ES V16 (All versions < V16 Update 1), Soft Starter ES V15.1 (All versions < V15.1 Update 3), Soft Starter ES V16 (All versions < V16 Update 1). Sending a specially crafted packet to the affected service could cause a partial remote denial-of-service, that would cause the service to restart itself.",Siemens,"Opcenter Execution Discrete,Opcenter Execution Foundation,Opcenter Execution Process,Opcenter Intelligence,Opcenter Quality,Opcenter Rd&l,Simatic It Lms,Simatic It Production Suite,Simatic Notifier Server For Windows,Simatic Pcs Neo,Simatic Step 7 (tia Portal) V15,Simatic Step 7 (tia Portal) V16,Simocode Es V15.1,Simocode Es V16,Soft Starter Es V15.1,Soft Starter Es V16",5.3,MEDIUM,0.0010999999940395355,false,,false,false,false,,false,false,2020-07-14T13:18:05.000Z,0 CVE-2020-7587,https://securityvulnerability.io/vulnerability/CVE-2020-7587,,"A vulnerability has been identified in Opcenter Execution Discrete (All versions < V3.2), Opcenter Execution Foundation (All versions < V3.2), Opcenter Execution Process (All versions < V3.2), Opcenter Intelligence (All versions < V3.3), Opcenter Quality (All versions < V11.3), Opcenter RD&L (V8.0), SIMATIC IT LMS (All versions < V2.6), SIMATIC IT Production Suite (All versions < V8.0), SIMATIC Notifier Server for Windows (All versions), SIMATIC PCS neo (All versions < V3.0 SP1), SIMATIC STEP 7 (TIA Portal) V15 (All versions < V15.1 Update 5), SIMATIC STEP 7 (TIA Portal) V16 (All versions < V16 Update 2), SIMOCODE ES V15.1 (All versions < V15.1 Update 4), SIMOCODE ES V16 (All versions < V16 Update 1), Soft Starter ES V15.1 (All versions < V15.1 Update 3), Soft Starter ES V16 (All versions < V16 Update 1). Sending multiple specially crafted packets to the affected service could cause a partial remote denial-of-service, that would cause the service to restart itself. On some cases the vulnerability could leak random information from the remote service.",Siemens,"Opcenter Execution Discrete,Opcenter Execution Foundation,Opcenter Execution Process,Opcenter Intelligence,Opcenter Quality,Opcenter Rd&l,Simatic It Lms,Simatic It Production Suite,Simatic Notifier Server For Windows,Simatic Pcs Neo,Simatic Step 7 (tia Portal) V15,Simatic Step 7 (tia Portal) V16,Simocode Es V15.1,Simocode Es V16,Soft Starter Es V15.1,Soft Starter Es V16",8.2,HIGH,0.002460000105202198,false,,false,false,false,,false,false,2020-07-14T13:18:05.000Z,0