cve,link,title,description,vendor,products,score,severity,epss,cisa,cisa_published,article,ransomware,exploited,poc,trended,trended_no_1,published,trended_score CVE-2024-49775,https://securityvulnerability.io/vulnerability/CVE-2024-49775,Heap-Based Buffer Overflow in Siemens Automation Products,"CVE-2024-49775 identifies a critical heap-based buffer overflow vulnerability affecting multiple Siemens automation products, including the Opcenter suite and the Totally Integrated Automation Portal (TIA Portal). This vulnerability resides in the integrated UMC component and could allow an unauthenticated remote attacker to execute arbitrary code. Given the widespread use of these products in industrial environments, the implications of such exploitation could lead to severe operational disruptions. Siemens has acknowledged this vulnerability in all listed versions and it is imperative for users to assess their current configurations and apply necessary mitigations.",Siemens,"Opcenter Execution Foundation,Opcenter Intelligence,Opcenter Quality,Opcenter Rdl,Simatic Pcs Neo V4.0,Simatic Pcs Neo V4.1,Simatic Pcs Neo V5.0,Sinec Nms,Totally Integrated Automation Portal (tia Portal) V16,Totally Integrated Automation Portal (tia Portal) V17,Totally Integrated Automation Portal (tia Portal) V18,Totally Integrated Automation Portal (tia Portal) V19",9.8,CRITICAL,0.000910000002477318,false,,false,false,false,,false,false,2024-12-16T15:06:04.714Z,184 CVE-2024-52051,https://securityvulnerability.io/vulnerability/CVE-2024-52051,"{""Vulnerability in Siemens PLCs and SCADA Systems Could Allow Arbitrary Code Execution""}","A vulnerability exists in various Siemens products, including SIMATIC S7-PLCSIM and TIA Portal, due to improper sanitization of user-controllable input when processing user settings. This flaw could enable local attackers to execute arbitrary commands on the host operating system, leveraging the privileges of the user running the affected software. Organizations utilizing these products should prioritize updates and apply security measures to mitigate potential risks.",Siemens,"Simatic S7-plcsim V17,Simatic S7-plcsim V18,Simatic Step 7 Safety V17,Simatic Step 7 Safety V18,Simatic Step 7 Safety V19,Simatic Step 7 V17,Simatic Step 7 V18,Simatic Step 7 V19,Simatic Wincc Unified Pc Runtime V18,Simatic Wincc Unified Pc Runtime V19,Simatic Wincc Unified V17,Simatic Wincc Unified V18,Simatic Wincc Unified V19,Simatic Wincc V17,Simatic Wincc V18,Simatic Wincc V19,Simocode Es V17,Simocode Es V18,Simocode Es V19,Simotion Scout Tia V5.4 Sp3,Simotion Scout Tia V5.5 Sp1,Simotion Scout Tia V5.6 Sp1,Sinamics Startdrive V17,Sinamics Startdrive V18,Sinamics Startdrive V19,Sirius Safety Es V17 (tia Portal),Sirius Safety Es V18 (tia Portal),Sirius Safety Es V19 (tia Portal),Sirius Soft Starter Es V17 (tia Portal),Sirius Soft Starter Es V18 (tia Portal),Sirius Soft Starter Es V19 (tia Portal),Tia Portal Cloud V17,Tia Portal Cloud V18,Tia Portal Cloud V19",7.3,HIGH,0.0004299999854993075,false,,false,false,false,,false,false,2024-12-10T13:53:57.576Z,0 CVE-2024-49849,https://securityvulnerability.io/vulnerability/CVE-2024-49849,"{""Vulnerability in Siemens Products Could Allow Arbitrary Code Execution""}","A vulnerability has been identified across multiple versions and products within Siemens' SIMATIC and TIA Portal lines. The flaw involves inadequate sanitization of user-controllable input when parsing log files, potentially allowing an attacker to exploit this weakness. This exploitation may lead to type confusion and the execution of arbitrary code within the affected applications, compromising operational integrity and security.",Siemens,"Simatic S7-plcsim V16,Simatic S7-plcsim V17,Simatic Step 7 Safety V16,Simatic Step 7 Safety V17,Simatic Step 7 Safety V18,Simatic Step 7 Safety V19,Simatic Step 7 V16,Simatic Step 7 V17,Simatic Step 7 V18,Simatic Step 7 V19,Simatic Wincc Unified V16,Simatic Wincc Unified V17,Simatic Wincc Unified V18,Simatic Wincc Unified V19,Simatic Wincc V16,Simatic Wincc V17,Simatic Wincc V18,Simatic Wincc V19,Simocode Es V16,Simocode Es V17,Simocode Es V18,Simocode Es V19,Simotion Scout Tia V5.4 Sp1,Simotion Scout Tia V5.4 Sp3,Simotion Scout Tia V5.5 Sp1,Simotion Scout Tia V5.6 Sp1,Sinamics Startdrive V16,Sinamics Startdrive V17,Sinamics Startdrive V18,Sinamics Startdrive V19,Sirius Safety Es V17 (tia Portal),Sirius Safety Es V18 (tia Portal),Sirius Safety Es V19 (tia Portal),Sirius Soft Starter Es V17 (tia Portal),Sirius Soft Starter Es V18 (tia Portal),Sirius Soft Starter Es V19 (tia Portal),Tia Portal Cloud V16,Tia Portal Cloud V17,Tia Portal Cloud V18,Tia Portal Cloud V19",7.8,HIGH,0.0005300000193528831,false,,false,false,false,,false,false,2024-12-10T13:53:56.043Z,0 CVE-2023-32736,https://securityvulnerability.io/vulnerability/CVE-2023-32736,"{""Vulnerability in Siemens Products Could Allow Arbitrary Code Execution""}","A vulnerability exists in various Siemens automation products that fail to adequately sanitize user-controllable input, especially when processing user settings. This flaw could facilitate type confusion, potentially allowing an attacker to execute arbitrary code within the affected application. Affected software includes SIMATIC S7-PLCSIM, STEP 7, WinCC, and other associated tools, and users are advised to review the latest updates and apply necessary patches to mitigate this risk. For detailed information, refer to the provided reference.",Siemens,"Simatic S7-plcsim V16,Simatic S7-plcsim V17,Simatic Step 7 Safety V16,Simatic Step 7 Safety V17,Simatic Step 7 Safety V18,Simatic Step 7 V16,Simatic Step 7 V17,Simatic Step 7 V18,Simatic Wincc Unified V16,Simatic Wincc Unified V17,Simatic Wincc Unified V18,Simatic Wincc V16,Simatic Wincc V17,Simatic Wincc V18,Simocode Es V16,Simocode Es V17,Simocode Es V18,Simotion Scout Tia V5.4 Sp1,Simotion Scout Tia V5.4 Sp3,Simotion Scout Tia V5.5 Sp1,Sinamics Startdrive V16,Sinamics Startdrive V17,Sinamics Startdrive V18,Sirius Safety Es V17,Sirius Safety Es V18,Sirius Soft Starter Es V17,Sirius Soft Starter Es V18,Tia Portal Cloud V16,Tia Portal Cloud V17,Tia Portal Cloud V18",7.3,HIGH,0.0004299999854993075,false,,false,false,false,,false,false,2024-11-12T12:49:22.651Z,0 CVE-2024-33698,https://securityvulnerability.io/vulnerability/CVE-2024-33698,Heap-Based Buffer Overflow in Opcenter and SIMATIC Products by Siemens,"A critical security vulnerability exists within the integrated UMC component of various Siemens products, including Opcenter and SIMATIC series. This vulnerability is characterized as a heap-based buffer overflow, which could potentially enable an unauthenticated remote attacker to execute arbitrary code on the affected systems. This flaw underscores the importance of regular updates and security patch management to protect industrial applications from malicious exploitation.",Siemens,"Opcenter Execution Foundation,Opcenter Quality,Opcenter Rdl,Simatic Information Server 2022,Simatic Information Server 2024,Simatic Pcs Neo V4.0,Simatic Pcs Neo V4.1,Simatic Pcs Neo V5.0,Sinec Nms,Totally Integrated Automation Portal (tia Portal) V16,Totally Integrated Automation Portal (tia Portal) V17,Totally Integrated Automation Portal (tia Portal) V18,Totally Integrated Automation Portal (tia Portal) V19",9.8,CRITICAL,0.0004299999854993075,false,,false,false,false,,false,false,2024-09-10T09:36:31.009Z,0 CVE-2023-32735,https://securityvulnerability.io/vulnerability/CVE-2023-32735,"{""Siemens: Multiple Products Affected by Deserialization Vulnerability"",""Siemens: Simatic Safety and Motion Control"",""Siemens: Sinamics Drive Technologies"",""Siemens: Simotion Safety"",""Siemens: TIA Portal Cloud""}","A vulnerability exists in various Siemens products, including SIMATIC STEP 7, SIMATIC WinCC, and other related applications, that fails to properly restrict .NET BinaryFormatter during the deserialization of hardware configuration profiles. This imperfection may lead to type confusion, enabling an attacker to execute arbitrary code within affected applications. This could result in unauthorized actions or data manipulation, posing a significant risk to system integrity and operations.",Siemens,"Simatic Step 7 Safety V16,Simatic Step 7 Safety V17,Simatic Step 7 Safety V18,Simatic Step 7 V16,Simatic Step 7 V17,Simatic Step 7 V18,Simatic Wincc Unified V16,Simatic Wincc Unified V17,Simatic Wincc Unified V18,Simatic Wincc V16,Simatic Wincc V17,Simatic Wincc V18,Simocode Es V16,Simocode Es V17,Simocode Es V18,Simotion Scout Tia V5.4 Sp1,Simotion Scout Tia V5.4 Sp3,Simotion Scout Tia V5.5 Sp1,Sinamics Startdrive V16,Sinamics Startdrive V17,Sinamics Startdrive V18,Sirius Safety Es V17,Sirius Safety Es V18,Sirius Soft Starter Es V17,Sirius Soft Starter Es V18,Soft Starter Es V16,Tia Portal Cloud V3.0",6.5,MEDIUM,0.0004299999854993075,false,,false,false,false,,false,false,2024-07-09T12:04:26.871Z,0 CVE-2023-46280,https://securityvulnerability.io/vulnerability/CVE-2023-46280,Out of Bounds Read Vulnerability in SIMATIC and TIA Portal Products by Siemens,"An out of bounds read vulnerability has been identified in multiple Siemens products, including the SIMATIC and TIA Portal series. This flaw can potentially lead to the crashing of the Windows kernel, resulting in a Blue Screen of Death (BSOD) error. Attackers could exploit this vulnerability to destabilize systems, impacting operational efficiency and safety within industrial environments. It is crucial for users of these products to be aware of this vulnerability and to implement necessary mitigations as outlined by Siemens.",Siemens,"Security Configuration Tool (sct),Simatic Automation Tool,Simatic Batch V9.1,Simatic Net Pc Software V16,Simatic Net Pc Software V17,Simatic Net Pc Software V18,Simatic Net Pc Software V19,Simatic Pcs 7 V9.1,Simatic Pdm V9.2,Simatic Route Control V9.1,Simatic S7-pct,Simatic Step 7 V5,Simatic Wincc Oa V3.17,Simatic Wincc Oa V3.18,Simatic Wincc Oa V3.19,Simatic Wincc Runtime Advanced,Simatic Wincc Runtime Professional V16,Simatic Wincc Runtime Professional V17,Simatic Wincc Runtime Professional V18,Simatic Wincc Runtime Professional V19,Simatic Wincc V7.4,Simatic Wincc V7.5,Simatic Wincc V8.0,Sinamics Startdrive,Sinec Nms,Sinumerik One Virtual,Sinumerik Plc Programming Tool,Tia Portal Cloud Connector,Totally Integrated Automation Portal (tia Portal) V15.1,Totally Integrated Automation Portal (tia Portal) V16,Totally Integrated Automation Portal (tia Portal) V17,Totally Integrated Automation Portal (tia Portal) V18,Totally Integrated Automation Portal (tia Portal) V19",6.5,MEDIUM,0.00044999999227002263,false,,false,false,false,,false,false,2024-05-14T10:01:52.069Z,0 CVE-2023-46284,https://securityvulnerability.io/vulnerability/CVE-2023-46284,Out of Bounds Write Vulnerability in Siemens Automation Products,"A significant out of bounds write vulnerability exists in various Siemens automation products, including Opcenter Execution Foundation and the Totally Integrated Automation Portal. This vulnerability arises when specific requests are processed on designated TCP ports (4002 and 4004), leading to a potential application crash. The affected services are designed to auto-restart following a crash, which may allow an attacker to exploit the application further. Timely updates to the latest versions are crucial for mitigating this risk.",Siemens,"Opcenter Execution Foundation,Opcenter Quality,Simatic Pcs Neo,Sinec Nms,Totally Integrated Automation Portal (tia Portal) V14,Totally Integrated Automation Portal (tia Portal) V15.1,Totally Integrated Automation Portal (tia Portal) V16,Totally Integrated Automation Portal (tia Portal) V17,Totally Integrated Automation Portal (tia Portal) V18",7.5,HIGH,0.0004299999854993075,false,,false,false,false,,false,false,2023-12-12T12:15:00.000Z,0 CVE-2023-46283,https://securityvulnerability.io/vulnerability/CVE-2023-46283,Out of Bounds Write Vulnerability in Opcenter and TIA Portal by Siemens,"A vulnerability exists in various Siemens software products that allows for an out of bounds write, potentially leading an attacker to crash the application while processing specific requests on a designated TCP port. Following the crash, the affected service is configured to automatically restart, which could be exploited by an attacker for further malicious actions. It's crucial for users of Opcenter Execution Foundation, TIA Portal, and related products to ensure they are running the latest versions to mitigate this risk.",Siemens,"Opcenter Execution Foundation,Opcenter Quality,Simatic Pcs Neo,Sinec Nms,Totally Integrated Automation Portal (tia Portal) V14,Totally Integrated Automation Portal (tia Portal) V15.1,Totally Integrated Automation Portal (tia Portal) V16,Totally Integrated Automation Portal (tia Portal) V17,Totally Integrated Automation Portal (tia Portal) V18",7.5,HIGH,0.0004299999854993075,false,,false,false,false,,false,false,2023-12-12T12:15:00.000Z,0 CVE-2023-46282,https://securityvulnerability.io/vulnerability/CVE-2023-46282,Reflected Cross-Site Scripting Vulnerability in Siemens Automation Products,"A reflected cross-site scripting vulnerability has been found in various Siemens automation products, including the Opcenter Execution Foundation and the Totally Integrated Automation Portal. This flaw allows attackers to inject arbitrary JavaScript code into the web interface, which could subsequently be executed by another user, potentially compromising their session and leading to unauthorized actions. The affected versions span multiple platforms, necessitating immediate attention for users of these critical systems.",Siemens,"Opcenter Execution Foundation,Opcenter Quality,Simatic Pcs Neo,Sinec Nms,Totally Integrated Automation Portal (tia Portal) V14,Totally Integrated Automation Portal (tia Portal) V15.1,Totally Integrated Automation Portal (tia Portal) V16,Totally Integrated Automation Portal (tia Portal) V17,Totally Integrated Automation Portal (tia Portal) V18",6.1,MEDIUM,0.0006799999973736703,false,,false,false,false,,false,false,2023-12-12T12:15:00.000Z,0 CVE-2023-46281,https://securityvulnerability.io/vulnerability/CVE-2023-46281,CORS Misconfiguration in Siemens Web Interfaces,"A vulnerability exists in the web interfaces of several Siemens products, where an overly permissive CORS policy could allow an attacker to exploit this misconfiguration. By manipulating CORS settings, an attacker could deceive legitimate users into triggering unintended actions, which may compromise the security of the user's session or expose sensitive data.",Siemens,"Opcenter Execution Foundation,Opcenter Quality,Simatic Pcs Neo,Sinec Nms,Totally Integrated Automation Portal (tia Portal) V14,Totally Integrated Automation Portal (tia Portal) V15.1,Totally Integrated Automation Portal (tia Portal) V16,Totally Integrated Automation Portal (tia Portal) V17,Totally Integrated Automation Portal (tia Portal) V18",8.8,HIGH,0.0018500000005587935,false,,false,false,false,,false,false,2023-12-12T12:15:00.000Z,0 CVE-2023-46285,https://securityvulnerability.io/vulnerability/CVE-2023-46285,Input Validation Vulnerability in Siemens Automation Products,"An improper input validation vulnerability exists in various Siemens automation products. This flaw can be exploited by sending specially crafted messages to the service running on port 4004/tcp, potentially leading to a Denial-of-Service condition. Notably, the affected services are designed to auto-restart once a failure is detected, which may make detection of the attack more challenging.",Siemens,"Opcenter Execution Foundation,Opcenter Quality,Simatic Pcs Neo,Sinec Nms,Totally Integrated Automation Portal (tia Portal) V14,Totally Integrated Automation Portal (tia Portal) V15.1,Totally Integrated Automation Portal (tia Portal) V16,Totally Integrated Automation Portal (tia Portal) V17,Totally Integrated Automation Portal (tia Portal) V18",7.5,HIGH,0.0004299999854993075,false,,false,false,false,,false,false,2023-12-12T12:15:00.000Z,0 CVE-2022-46141,https://securityvulnerability.io/vulnerability/CVE-2022-46141,Information Disclosure Vulnerability in SIMATIC STEP 7 (TIA Portal) by Siemens,"An information disclosure issue has been found in SIMATIC STEP 7 (TIA Portal), affecting all versions prior to V19. This flaw allows a local attacker to access the access level password of the SIMATIC S7-1200 and S7-1500 CPUs. The vulnerability is triggered when a legitimate user enters their password during hardware configuration, potentially exposing sensitive credentials to unauthorized individuals.",Siemens,Simatic Step 7 (tia Portal),4.2,MEDIUM,0.0004199999966658652,false,,false,false,false,,false,false,2023-12-12T11:25:26.583Z,0 CVE-2023-30757,https://securityvulnerability.io/vulnerability/CVE-2023-30757,Know-How Protection Flaw in Siemens Totally Integrated Automation Portal Products,"A critical vulnerability exists within Siemens Totally Integrated Automation Portal products that impacts the know-how protection feature. When project files are updated, the encryption for existing program blocks is not properly refreshed, permitting attackers with access to the project files to retrieve older, unprotected versions of the project. This unauthorized access occurs without requiring the know-how protection password, posing a significant risk to the confidentiality and integrity of sensitive automation data.",Siemens,"Totally Integrated Automation Portal (tia Portal) V14,Totally Integrated Automation Portal (tia Portal) V15,Totally Integrated Automation Portal (tia Portal) V15.1,Totally Integrated Automation Portal (tia Portal) V16,Totally Integrated Automation Portal (tia Portal) V17,Totally Integrated Automation Portal (tia Portal) V18,Totally Integrated Automation Portal (tia Portal) V19,Totally Integrated Automation Portal (tia Portal) V20",5.5,MEDIUM,0.0004400000034365803,false,,false,false,false,,false,false,2023-06-13T09:15:00.000Z,0 CVE-2023-26293,https://securityvulnerability.io/vulnerability/CVE-2023-26293,Path Traversal Vulnerability in Siemens Totally Integrated Automation Portal,"A path traversal vulnerability has been discovered in Siemens' Totally Integrated Automation Portal, impacting various versions. This flaw could allow an attacker to write or modify arbitrary files within the engineering system. If users inadvertently open a compromised PC system configuration file, it may lead to unauthorized code execution, posing significant security risks.",Siemens,"Totally Integrated Automation Portal (tia Portal) V15,Totally Integrated Automation Portal (tia Portal) V16,Totally Integrated Automation Portal (tia Portal) V17,Totally Integrated Automation Portal (tia Portal) V18",7.3,HIGH,0.0006200000061653554,false,,false,false,false,,false,false,2023-04-11T10:15:00.000Z,0 CVE-2022-27194,https://securityvulnerability.io/vulnerability/CVE-2022-27194,,"A vulnerability has been identified in SIMATIC PCS neo (Administration Console) (All versions < V3.1 SP1), SINETPLAN (All versions), TIA Portal (V15, V15.1, V16 and V17). The affected system cannot properly process specially crafted packets sent to port 8888/tcp. A remote attacker could exploit this vulnerability to cause a Denial-of-Service condition. The affected devices must be restarted manually.",Siemens,"Simatic Pcs Neo (administration Console),Sinetplan,Tia Portal",7.5,HIGH,0.0017900000093504786,false,,false,false,false,,false,false,2022-04-12T09:07:59.000Z,0 CVE-2021-42029,https://securityvulnerability.io/vulnerability/CVE-2021-42029,,"A vulnerability has been identified in SIMATIC STEP 7 (TIA Portal) V15 (All versions), SIMATIC STEP 7 (TIA Portal) V16 (All versions < V16 Update 5), SIMATIC STEP 7 (TIA Portal) V17 (All versions < V17 Update 2). An attacker could achieve privilege escalation on the web server of certain devices due to improper access control vulnerability in the engineering system software. The attacker needs to have direct access to the impacted web server.",Siemens,"Simatic Step 7 (tia Portal) V15,Simatic Step 7 (tia Portal) V16,Simatic Step 7 (tia Portal) V17",7.8,HIGH,0.0004400000034365803,false,,false,false,false,,false,false,2022-04-12T09:07:30.000Z,0 CVE-2020-25238,https://securityvulnerability.io/vulnerability/CVE-2020-25238,,"A vulnerability has been identified in PCS neo (Administration Console) (All versions < V3.1), TIA Portal (V15, V15.1 and V16). Manipulating certain files in specific folders could allow a local attacker to execute code with SYSTEM privileges. The security vulnerability could be exploited by an attacker with a valid account and limited access rights on the system.",Siemens,"Pcs Neo (administration Console),Tia Portal",7.8,HIGH,0.0004299999854993075,false,,false,false,false,,false,false,2021-02-09T15:38:18.000Z,0 CVE-2020-7587,https://securityvulnerability.io/vulnerability/CVE-2020-7587,,"A vulnerability has been identified in Opcenter Execution Discrete (All versions < V3.2), Opcenter Execution Foundation (All versions < V3.2), Opcenter Execution Process (All versions < V3.2), Opcenter Intelligence (All versions < V3.3), Opcenter Quality (All versions < V11.3), Opcenter RD&L (V8.0), SIMATIC IT LMS (All versions < V2.6), SIMATIC IT Production Suite (All versions < V8.0), SIMATIC Notifier Server for Windows (All versions), SIMATIC PCS neo (All versions < V3.0 SP1), SIMATIC STEP 7 (TIA Portal) V15 (All versions < V15.1 Update 5), SIMATIC STEP 7 (TIA Portal) V16 (All versions < V16 Update 2), SIMOCODE ES V15.1 (All versions < V15.1 Update 4), SIMOCODE ES V16 (All versions < V16 Update 1), Soft Starter ES V15.1 (All versions < V15.1 Update 3), Soft Starter ES V16 (All versions < V16 Update 1). Sending multiple specially crafted packets to the affected service could cause a partial remote denial-of-service, that would cause the service to restart itself. On some cases the vulnerability could leak random information from the remote service.",Siemens,"Opcenter Execution Discrete,Opcenter Execution Foundation,Opcenter Execution Process,Opcenter Intelligence,Opcenter Quality,Opcenter Rd&l,Simatic It Lms,Simatic It Production Suite,Simatic Notifier Server For Windows,Simatic Pcs Neo,Simatic Step 7 (tia Portal) V15,Simatic Step 7 (tia Portal) V16,Simocode Es V15.1,Simocode Es V16,Soft Starter Es V15.1,Soft Starter Es V16",8.2,HIGH,0.002460000105202198,false,,false,false,false,,false,false,2020-07-14T13:18:05.000Z,0 CVE-2020-7588,https://securityvulnerability.io/vulnerability/CVE-2020-7588,,"A vulnerability has been identified in Opcenter Execution Discrete (All versions < V3.2), Opcenter Execution Foundation (All versions < V3.2), Opcenter Execution Process (All versions < V3.2), Opcenter Intelligence (All versions < V3.3), Opcenter Quality (All versions < V11.3), Opcenter RD&L (V8.0), SIMATIC IT LMS (All versions < V2.6), SIMATIC IT Production Suite (All versions < V8.0), SIMATIC Notifier Server for Windows (All versions), SIMATIC PCS neo (All versions < V3.0 SP1), SIMATIC STEP 7 (TIA Portal) V15 (All versions < V15.1 Update 5), SIMATIC STEP 7 (TIA Portal) V16 (All versions < V16 Update 2), SIMOCODE ES V15.1 (All versions < V15.1 Update 4), SIMOCODE ES V16 (All versions < V16 Update 1), Soft Starter ES V15.1 (All versions < V15.1 Update 3), Soft Starter ES V16 (All versions < V16 Update 1). Sending a specially crafted packet to the affected service could cause a partial remote denial-of-service, that would cause the service to restart itself.",Siemens,"Opcenter Execution Discrete,Opcenter Execution Foundation,Opcenter Execution Process,Opcenter Intelligence,Opcenter Quality,Opcenter Rd&l,Simatic It Lms,Simatic It Production Suite,Simatic Notifier Server For Windows,Simatic Pcs Neo,Simatic Step 7 (tia Portal) V15,Simatic Step 7 (tia Portal) V16,Simocode Es V15.1,Simocode Es V16,Soft Starter Es V15.1,Soft Starter Es V16",5.3,MEDIUM,0.0010999999940395355,false,,false,false,false,,false,false,2020-07-14T13:18:05.000Z,0 CVE-2020-7581,https://securityvulnerability.io/vulnerability/CVE-2020-7581,,"A vulnerability has been identified in Opcenter Execution Discrete (All versions < V3.2), Opcenter Execution Foundation (All versions < V3.2), Opcenter Execution Process (All versions < V3.2), Opcenter Intelligence (All versions < V3.3), Opcenter Quality (All versions < V11.3), Opcenter RD&L (V8.0), SIMATIC Notifier Server for Windows (All versions), SIMATIC PCS neo (All versions < V3.0 SP1), SIMATIC STEP 7 (TIA Portal) V15 (All versions < V15.1 Update 5), SIMATIC STEP 7 (TIA Portal) V16 (All versions < V16 Update 2), SIMOCODE ES V15.1 (All versions < V15.1 Update 4), SIMOCODE ES V16 (All versions < V16 Update 1), Soft Starter ES V15.1 (All versions < V15.1 Update 3), Soft Starter ES V16 (All versions < V16 Update 1). A component within the affected application calls a helper binary with SYSTEM privileges during startup while the call path is not quoted. This could allow a local attacker with administrative privileges to execute code with SYSTEM level privileges.",Siemens,"Opcenter Execution Discrete,Opcenter Execution Foundation,Opcenter Execution Process,Opcenter Intelligence,Opcenter Quality,Opcenter Rd&l,Simatic Notifier Server For Windows,Simatic Pcs Neo,Simatic Step 7 (tia Portal) V15,Simatic Step 7 (tia Portal) V16,Simocode Es V15.1,Simocode Es V16,Soft Starter Es V15.1,Soft Starter Es V16",6.7,MEDIUM,0.0004199999966658652,false,,false,false,false,,false,false,2020-07-14T13:18:05.000Z,0 CVE-2020-7580,https://securityvulnerability.io/vulnerability/CVE-2020-7580,,"A vulnerability has been identified in SIMATIC Automation Tool (All versions < V4 SP2), SIMATIC NET PC Software V14 (All versions < V14 SP1 Update 14), SIMATIC NET PC Software V15 (All versions), SIMATIC NET PC Software V16 (All versions < V16 Upd3), SIMATIC PCS neo (All versions < V3.0 SP1), SIMATIC ProSave (All versions < V17), SIMATIC S7-1500 Software Controller (All versions < V21.8), SIMATIC STEP 7 (TIA Portal) V13 (All versions < V13 SP2 Update 4), SIMATIC STEP 7 (TIA Portal) V14 (All versions < V14 SP1 Update 10), SIMATIC STEP 7 (TIA Portal) V15 (All versions < V15.1 Update 5), SIMATIC STEP 7 (TIA Portal) V16 (All versions < V16 Update 2), SIMATIC STEP 7 V5 (All versions < V5.6 SP2 HF3), SIMATIC WinCC OA V3.16 (All versions < V3.16 P018), SIMATIC WinCC OA V3.17 (All versions < V3.17 P003), SIMATIC WinCC Runtime Advanced (All versions < V16 Update 2), SIMATIC WinCC Runtime Professional V13 (All versions < V13 SP2 Update 4), SIMATIC WinCC Runtime Professional V14 (All versions < V14 SP1 Update 10), SIMATIC WinCC Runtime Professional V15 (All versions < V15.1 Update 5), SIMATIC WinCC Runtime Professional V16 (All versions < V16 Update 2), SIMATIC WinCC V7.4 (All versions < V7.4 SP1 Update 14), SIMATIC WinCC V7.5 (All versions < V7.5 SP1 Update 3), SINAMICS STARTER (All Versions < V5.4 HF2), SINAMICS Startdrive (All Versions < V16 Update 3), SINEC NMS (All versions < V1.0 SP2), SINEMA Server (All versions < V14 SP3), SINUMERIK ONE virtual (All Versions < V6.14), SINUMERIK Operate (All Versions < V6.14). A common component used by the affected applications regularly calls a helper binary with SYSTEM privileges while the call path is not quoted. This could allow a local attacker to execute arbitrary code with SYTEM privileges.",Siemens,"Simatic Automation Tool,Simatic Net Pc Software V14,Simatic Net Pc Software V15,Simatic Net Pc Software V16,Simatic Pcs Neo,Simatic Prosave,Simatic S7-1500 Software Controller,Simatic Step 7 (tia Portal) V13,Simatic Step 7 (tia Portal) V14,Simatic Step 7 (tia Portal) V15,Simatic Step 7 (tia Portal) V16,Simatic Step 7 V5,Simatic Wincc Oa V3.16,Simatic Wincc Oa V3.17,Simatic Wincc Runtime Advanced,Simatic Wincc Runtime Professional V13,Simatic Wincc Runtime Professional V14,Simatic Wincc Runtime Professional V15,Simatic Wincc Runtime Professional V16,Simatic Wincc V7.4,Simatic Wincc V7.5,Sinamics Starter,Sinamics Startdrive,Sinec Nms,Sinema Server,Sinumerik One Virtual,Sinumerik Operate",6.7,MEDIUM,0.0004600000102072954,false,,false,false,false,,false,false,2020-06-10T00:00:00.000Z,0 CVE-2019-19282,https://securityvulnerability.io/vulnerability/CVE-2019-19282,,"A vulnerability has been identified in OpenPCS 7 V8.1 (All versions), OpenPCS 7 V8.2 (All versions), OpenPCS 7 V9.0 (All versions < V9.0 Upd3), SIMATIC BATCH V8.1 (All versions), SIMATIC BATCH V8.2 (All versions < V8.2 Upd12), SIMATIC BATCH V9.0 (All versions < V9.0 SP1 Upd5), SIMATIC NET PC Software V14 (All versions < V14 SP1 Update 14), SIMATIC NET PC Software V15 (All versions), SIMATIC NET PC Software V16 (All versions < V16 Update 1), SIMATIC PCS 7 V8.1 (All versions), SIMATIC PCS 7 V8.2 (All versions), SIMATIC PCS 7 V9.0 (All versions < V9.0 SP3), SIMATIC Route Control V8.1 (All versions), SIMATIC Route Control V8.2 (All versions), SIMATIC Route Control V9.0 (All versions < V9.0 Upd4), SIMATIC WinCC (TIA Portal) V13 (All versions < V13 SP2), SIMATIC WinCC (TIA Portal) V14 (All versions < V14 SP1 Update 10), SIMATIC WinCC (TIA Portal) V15.1 (All versions < V15.1 Update 5), SIMATIC WinCC (TIA Portal) V16 (All versions < V16 Update 1), SIMATIC WinCC V7.3 (All versions), SIMATIC WinCC V7.4 (All versions < V7.4 SP1 Update 14), SIMATIC WinCC V7.5 (All versions < V7.5 SP1 Update 1). Through specially crafted messages, when encrypted communication is enabled, an attacker with network access could use the vulnerability to compromise the availability of the system by causing a Denial-of-Service condition. Successful exploitation requires no system privileges and no user interaction.",Siemens,"Openpcs 7 V8.1,Openpcs 7 V8.2,Openpcs 7 V9.0,Simatic Batch V8.1,Simatic Batch V8.2,Simatic Batch V9.0,Simatic Net Pc Software V14,Simatic Net Pc Software V15,Simatic Net Pc Software V16,Simatic Pcs 7 V8.1,Simatic Pcs 7 V8.2,Simatic Pcs 7 V9.0,Simatic Route Control V8.1,Simatic Route Control V8.2,Simatic Route Control V9.0,Simatic Wincc (tia Portal) V13,Simatic Wincc (tia Portal) V14,Simatic Wincc (tia Portal) V15.1,Simatic Wincc (tia Portal) V16,Simatic Wincc V7.3,Simatic Wincc V7.4,Simatic Wincc V7.5",7.5,HIGH,0.0010600000387057662,false,,false,false,false,,false,false,2020-03-10T19:16:17.000Z,0 CVE-2019-10934,https://securityvulnerability.io/vulnerability/CVE-2019-10934,,"A vulnerability has been identified in TIA Portal V14 (All versions), TIA Portal V15 (All versions < V15.1 Update 7), TIA Portal V16 (All versions < V16 Update 6), TIA Portal V17 (All versions < V17 Update 4). Changing the contents of a configuration file could allow an attacker to execute arbitrary code with SYSTEM privileges. The security vulnerability could be exploited by an attacker with a valid account and limited access rights on the system. No user interaction is required. At the time of advisory publication no public exploitation of this security vulnerability was known.",Siemens,"Tia Portal V14,Tia Portal V15,Tia Portal V16,Tia Portal V17",7.8,HIGH,0.0004400000034365803,false,,false,false,false,,false,false,2020-01-16T15:35:24.000Z,0 CVE-2019-10929,https://securityvulnerability.io/vulnerability/CVE-2019-10929,,"A vulnerability has been identified in SIMATIC CP 1626 (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants) (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions < V20.8), SIMATIC HMI Panel (incl. SIPLUS variants) (All versions), SIMATIC NET PC Software V14 (All versions < V14 SP1 Update 14), SIMATIC NET PC Software V15 (All versions), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions < V4.4.0), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions < V2.8.1), SIMATIC S7-1500 Software Controller (All versions < V20.8), SIMATIC S7-PLCSIM Advanced (All versions < V3.0), SIMATIC STEP 7 (TIA Portal) (All versions < V16), SIMATIC WinCC (TIA Portal) (All versions < V16), SIMATIC WinCC OA (All versions < V3.16 P013), SIMATIC WinCC Runtime Advanced (All versions < V16), SIMATIC WinCC Runtime Professional (All versions < V16), TIM 1531 IRC (incl. SIPLUS NET variants) (All versions < V2.1). Affected devices contain a message protection bypass vulnerability due to certain properties in the calculation used for integrity protection. This could allow an attacker in a Man-in-the-Middle position to modify network traffic sent on port 102/tcp to the affected devices.",Siemens,"Simatic Cp 1626,Simatic Et 200sp Open Controller Cpu 1515sp Pc (incl. Siplus Variants),Simatic Et 200sp Open Controller Cpu 1515sp Pc2 (incl. Siplus Variants),Simatic Hmi Panel (incl. Siplus Variants),Simatic Net Pc Software V14,Simatic Net Pc Software V15,Simatic S7-1200 Cpu Family (incl. Siplus Variants),Simatic S7-1500 Cpu Family (incl. Related Et200 Cpus And Siplus Variants),Simatic S7-1500 Software Controller,Simatic S7-plcsim Advanced,Simatic Step 7 (tia Portal),Simatic Wincc (tia Portal),Simatic Wincc Oa,Simatic Wincc Runtime Advanced,Simatic Wincc Runtime Professional,Tim 1531 Irc (incl. Siplus Net Variants)",5.9,MEDIUM,0.002360000042244792,false,,false,false,false,,false,false,2019-08-13T18:55:57.000Z,0