cve,link,title,description,vendor,products,score,severity,epss,cisa,cisa_published,article,ransomware,exploited,poc,trended,trended_no_1,published,trended_score CVE-2024-52051,https://securityvulnerability.io/vulnerability/CVE-2024-52051,"{""Vulnerability in Siemens PLCs and SCADA Systems Could Allow Arbitrary Code Execution""}","A vulnerability exists in various Siemens products, including SIMATIC S7-PLCSIM and TIA Portal, due to improper sanitization of user-controllable input when processing user settings. This flaw could enable local attackers to execute arbitrary commands on the host operating system, leveraging the privileges of the user running the affected software. Organizations utilizing these products should prioritize updates and apply security measures to mitigate potential risks.",Siemens,"Simatic S7-plcsim V17,Simatic S7-plcsim V18,Simatic Step 7 Safety V17,Simatic Step 7 Safety V18,Simatic Step 7 Safety V19,Simatic Step 7 V17,Simatic Step 7 V18,Simatic Step 7 V19,Simatic Wincc Unified Pc Runtime V18,Simatic Wincc Unified Pc Runtime V19,Simatic Wincc Unified V17,Simatic Wincc Unified V18,Simatic Wincc Unified V19,Simatic Wincc V17,Simatic Wincc V18,Simatic Wincc V19,Simocode Es V17,Simocode Es V18,Simocode Es V19,Simotion Scout Tia V5.4 Sp3,Simotion Scout Tia V5.5 Sp1,Simotion Scout Tia V5.6 Sp1,Sinamics Startdrive V17,Sinamics Startdrive V18,Sinamics Startdrive V19,Sirius Safety Es V17 (tia Portal),Sirius Safety Es V18 (tia Portal),Sirius Safety Es V19 (tia Portal),Sirius Soft Starter Es V17 (tia Portal),Sirius Soft Starter Es V18 (tia Portal),Sirius Soft Starter Es V19 (tia Portal),Tia Portal Cloud V17,Tia Portal Cloud V18,Tia Portal Cloud V19",7.3,HIGH,0.0004299999854993075,false,,false,false,false,,false,false,2024-12-10T13:53:57.576Z,0 CVE-2024-49849,https://securityvulnerability.io/vulnerability/CVE-2024-49849,"{""Vulnerability in Siemens Products Could Allow Arbitrary Code Execution""}","A vulnerability has been identified across multiple versions and products within Siemens' SIMATIC and TIA Portal lines. The flaw involves inadequate sanitization of user-controllable input when parsing log files, potentially allowing an attacker to exploit this weakness. This exploitation may lead to type confusion and the execution of arbitrary code within the affected applications, compromising operational integrity and security.",Siemens,"Simatic S7-plcsim V16,Simatic S7-plcsim V17,Simatic Step 7 Safety V16,Simatic Step 7 Safety V17,Simatic Step 7 Safety V18,Simatic Step 7 Safety V19,Simatic Step 7 V16,Simatic Step 7 V17,Simatic Step 7 V18,Simatic Step 7 V19,Simatic Wincc Unified V16,Simatic Wincc Unified V17,Simatic Wincc Unified V18,Simatic Wincc Unified V19,Simatic Wincc V16,Simatic Wincc V17,Simatic Wincc V18,Simatic Wincc V19,Simocode Es V16,Simocode Es V17,Simocode Es V18,Simocode Es V19,Simotion Scout Tia V5.4 Sp1,Simotion Scout Tia V5.4 Sp3,Simotion Scout Tia V5.5 Sp1,Simotion Scout Tia V5.6 Sp1,Sinamics Startdrive V16,Sinamics Startdrive V17,Sinamics Startdrive V18,Sinamics Startdrive V19,Sirius Safety Es V17 (tia Portal),Sirius Safety Es V18 (tia Portal),Sirius Safety Es V19 (tia Portal),Sirius Soft Starter Es V17 (tia Portal),Sirius Soft Starter Es V18 (tia Portal),Sirius Soft Starter Es V19 (tia Portal),Tia Portal Cloud V16,Tia Portal Cloud V17,Tia Portal Cloud V18,Tia Portal Cloud V19",7.8,HIGH,0.0005300000193528831,false,,false,false,false,,false,false,2024-12-10T13:53:56.043Z,0 CVE-2023-32736,https://securityvulnerability.io/vulnerability/CVE-2023-32736,"{""Vulnerability in Siemens Products Could Allow Arbitrary Code Execution""}","A vulnerability exists in various Siemens automation products that fail to adequately sanitize user-controllable input, especially when processing user settings. This flaw could facilitate type confusion, potentially allowing an attacker to execute arbitrary code within the affected application. Affected software includes SIMATIC S7-PLCSIM, STEP 7, WinCC, and other associated tools, and users are advised to review the latest updates and apply necessary patches to mitigate this risk. For detailed information, refer to the provided reference.",Siemens,"Simatic S7-plcsim V16,Simatic S7-plcsim V17,Simatic Step 7 Safety V16,Simatic Step 7 Safety V17,Simatic Step 7 Safety V18,Simatic Step 7 V16,Simatic Step 7 V17,Simatic Step 7 V18,Simatic Wincc Unified V16,Simatic Wincc Unified V17,Simatic Wincc Unified V18,Simatic Wincc V16,Simatic Wincc V17,Simatic Wincc V18,Simocode Es V16,Simocode Es V17,Simocode Es V18,Simotion Scout Tia V5.4 Sp1,Simotion Scout Tia V5.4 Sp3,Simotion Scout Tia V5.5 Sp1,Sinamics Startdrive V16,Sinamics Startdrive V17,Sinamics Startdrive V18,Sirius Safety Es V17,Sirius Safety Es V18,Sirius Soft Starter Es V17,Sirius Soft Starter Es V18,Tia Portal Cloud V16,Tia Portal Cloud V17,Tia Portal Cloud V18",7.3,HIGH,0.0004299999854993075,false,,false,false,false,,false,false,2024-11-12T12:49:22.651Z,0 CVE-2023-32735,https://securityvulnerability.io/vulnerability/CVE-2023-32735,"{""Siemens: Multiple Products Affected by Deserialization Vulnerability"",""Siemens: Simatic Safety and Motion Control"",""Siemens: Sinamics Drive Technologies"",""Siemens: Simotion Safety"",""Siemens: TIA Portal Cloud""}","A vulnerability exists in various Siemens products, including SIMATIC STEP 7, SIMATIC WinCC, and other related applications, that fails to properly restrict .NET BinaryFormatter during the deserialization of hardware configuration profiles. This imperfection may lead to type confusion, enabling an attacker to execute arbitrary code within affected applications. This could result in unauthorized actions or data manipulation, posing a significant risk to system integrity and operations.",Siemens,"Simatic Step 7 Safety V16,Simatic Step 7 Safety V17,Simatic Step 7 Safety V18,Simatic Step 7 V16,Simatic Step 7 V17,Simatic Step 7 V18,Simatic Wincc Unified V16,Simatic Wincc Unified V17,Simatic Wincc Unified V18,Simatic Wincc V16,Simatic Wincc V17,Simatic Wincc V18,Simocode Es V16,Simocode Es V17,Simocode Es V18,Simotion Scout Tia V5.4 Sp1,Simotion Scout Tia V5.4 Sp3,Simotion Scout Tia V5.5 Sp1,Sinamics Startdrive V16,Sinamics Startdrive V17,Sinamics Startdrive V18,Sirius Safety Es V17,Sirius Safety Es V18,Sirius Soft Starter Es V17,Sirius Soft Starter Es V18,Soft Starter Es V16,Tia Portal Cloud V3.0",6.5,MEDIUM,0.0004299999854993075,false,,false,false,false,,false,false,2024-07-09T12:04:26.871Z,0 CVE-2023-46280,https://securityvulnerability.io/vulnerability/CVE-2023-46280,Out of Bounds Read Vulnerability in SIMATIC and TIA Portal Products by Siemens,"An out of bounds read vulnerability has been identified in multiple Siemens products, including the SIMATIC and TIA Portal series. This flaw can potentially lead to the crashing of the Windows kernel, resulting in a Blue Screen of Death (BSOD) error. Attackers could exploit this vulnerability to destabilize systems, impacting operational efficiency and safety within industrial environments. It is crucial for users of these products to be aware of this vulnerability and to implement necessary mitigations as outlined by Siemens.",Siemens,"Security Configuration Tool (sct),Simatic Automation Tool,Simatic Batch V9.1,Simatic Net Pc Software V16,Simatic Net Pc Software V17,Simatic Net Pc Software V18,Simatic Net Pc Software V19,Simatic Pcs 7 V9.1,Simatic Pdm V9.2,Simatic Route Control V9.1,Simatic S7-pct,Simatic Step 7 V5,Simatic Wincc Oa V3.17,Simatic Wincc Oa V3.18,Simatic Wincc Oa V3.19,Simatic Wincc Runtime Advanced,Simatic Wincc Runtime Professional V16,Simatic Wincc Runtime Professional V17,Simatic Wincc Runtime Professional V18,Simatic Wincc Runtime Professional V19,Simatic Wincc V7.4,Simatic Wincc V7.5,Simatic Wincc V8.0,Sinamics Startdrive,Sinec Nms,Sinumerik One Virtual,Sinumerik Plc Programming Tool,Tia Portal Cloud Connector,Totally Integrated Automation Portal (tia Portal) V15.1,Totally Integrated Automation Portal (tia Portal) V16,Totally Integrated Automation Portal (tia Portal) V17,Totally Integrated Automation Portal (tia Portal) V18,Totally Integrated Automation Portal (tia Portal) V19",6.5,MEDIUM,0.00044999999227002263,false,,false,false,false,,false,false,2024-05-14T10:01:52.069Z,0 CVE-2020-7580,https://securityvulnerability.io/vulnerability/CVE-2020-7580,,"A vulnerability has been identified in SIMATIC Automation Tool (All versions < V4 SP2), SIMATIC NET PC Software V14 (All versions < V14 SP1 Update 14), SIMATIC NET PC Software V15 (All versions), SIMATIC NET PC Software V16 (All versions < V16 Upd3), SIMATIC PCS neo (All versions < V3.0 SP1), SIMATIC ProSave (All versions < V17), SIMATIC S7-1500 Software Controller (All versions < V21.8), SIMATIC STEP 7 (TIA Portal) V13 (All versions < V13 SP2 Update 4), SIMATIC STEP 7 (TIA Portal) V14 (All versions < V14 SP1 Update 10), SIMATIC STEP 7 (TIA Portal) V15 (All versions < V15.1 Update 5), SIMATIC STEP 7 (TIA Portal) V16 (All versions < V16 Update 2), SIMATIC STEP 7 V5 (All versions < V5.6 SP2 HF3), SIMATIC WinCC OA V3.16 (All versions < V3.16 P018), SIMATIC WinCC OA V3.17 (All versions < V3.17 P003), SIMATIC WinCC Runtime Advanced (All versions < V16 Update 2), SIMATIC WinCC Runtime Professional V13 (All versions < V13 SP2 Update 4), SIMATIC WinCC Runtime Professional V14 (All versions < V14 SP1 Update 10), SIMATIC WinCC Runtime Professional V15 (All versions < V15.1 Update 5), SIMATIC WinCC Runtime Professional V16 (All versions < V16 Update 2), SIMATIC WinCC V7.4 (All versions < V7.4 SP1 Update 14), SIMATIC WinCC V7.5 (All versions < V7.5 SP1 Update 3), SINAMICS STARTER (All Versions < V5.4 HF2), SINAMICS Startdrive (All Versions < V16 Update 3), SINEC NMS (All versions < V1.0 SP2), SINEMA Server (All versions < V14 SP3), SINUMERIK ONE virtual (All Versions < V6.14), SINUMERIK Operate (All Versions < V6.14). A common component used by the affected applications regularly calls a helper binary with SYSTEM privileges while the call path is not quoted. This could allow a local attacker to execute arbitrary code with SYTEM privileges.",Siemens,"Simatic Automation Tool,Simatic Net Pc Software V14,Simatic Net Pc Software V15,Simatic Net Pc Software V16,Simatic Pcs Neo,Simatic Prosave,Simatic S7-1500 Software Controller,Simatic Step 7 (tia Portal) V13,Simatic Step 7 (tia Portal) V14,Simatic Step 7 (tia Portal) V15,Simatic Step 7 (tia Portal) V16,Simatic Step 7 V5,Simatic Wincc Oa V3.16,Simatic Wincc Oa V3.17,Simatic Wincc Runtime Advanced,Simatic Wincc Runtime Professional V13,Simatic Wincc Runtime Professional V14,Simatic Wincc Runtime Professional V15,Simatic Wincc Runtime Professional V16,Simatic Wincc V7.4,Simatic Wincc V7.5,Sinamics Starter,Sinamics Startdrive,Sinec Nms,Sinema Server,Sinumerik One Virtual,Sinumerik Operate",6.7,MEDIUM,0.0004600000102072954,false,,false,false,false,,false,false,2020-06-10T00:00:00.000Z,0 CVE-2019-19282,https://securityvulnerability.io/vulnerability/CVE-2019-19282,,"A vulnerability has been identified in OpenPCS 7 V8.1 (All versions), OpenPCS 7 V8.2 (All versions), OpenPCS 7 V9.0 (All versions < V9.0 Upd3), SIMATIC BATCH V8.1 (All versions), SIMATIC BATCH V8.2 (All versions < V8.2 Upd12), SIMATIC BATCH V9.0 (All versions < V9.0 SP1 Upd5), SIMATIC NET PC Software V14 (All versions < V14 SP1 Update 14), SIMATIC NET PC Software V15 (All versions), SIMATIC NET PC Software V16 (All versions < V16 Update 1), SIMATIC PCS 7 V8.1 (All versions), SIMATIC PCS 7 V8.2 (All versions), SIMATIC PCS 7 V9.0 (All versions < V9.0 SP3), SIMATIC Route Control V8.1 (All versions), SIMATIC Route Control V8.2 (All versions), SIMATIC Route Control V9.0 (All versions < V9.0 Upd4), SIMATIC WinCC (TIA Portal) V13 (All versions < V13 SP2), SIMATIC WinCC (TIA Portal) V14 (All versions < V14 SP1 Update 10), SIMATIC WinCC (TIA Portal) V15.1 (All versions < V15.1 Update 5), SIMATIC WinCC (TIA Portal) V16 (All versions < V16 Update 1), SIMATIC WinCC V7.3 (All versions), SIMATIC WinCC V7.4 (All versions < V7.4 SP1 Update 14), SIMATIC WinCC V7.5 (All versions < V7.5 SP1 Update 1). Through specially crafted messages, when encrypted communication is enabled, an attacker with network access could use the vulnerability to compromise the availability of the system by causing a Denial-of-Service condition. Successful exploitation requires no system privileges and no user interaction.",Siemens,"Openpcs 7 V8.1,Openpcs 7 V8.2,Openpcs 7 V9.0,Simatic Batch V8.1,Simatic Batch V8.2,Simatic Batch V9.0,Simatic Net Pc Software V14,Simatic Net Pc Software V15,Simatic Net Pc Software V16,Simatic Pcs 7 V8.1,Simatic Pcs 7 V8.2,Simatic Pcs 7 V9.0,Simatic Route Control V8.1,Simatic Route Control V8.2,Simatic Route Control V9.0,Simatic Wincc (tia Portal) V13,Simatic Wincc (tia Portal) V14,Simatic Wincc (tia Portal) V15.1,Simatic Wincc (tia Portal) V16,Simatic Wincc V7.3,Simatic Wincc V7.4,Simatic Wincc V7.5",7.5,HIGH,0.0010600000387057662,false,,false,false,false,,false,false,2020-03-10T19:16:17.000Z,0 CVE-2019-10929,https://securityvulnerability.io/vulnerability/CVE-2019-10929,,"A vulnerability has been identified in SIMATIC CP 1626 (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants) (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions < V20.8), SIMATIC HMI Panel (incl. SIPLUS variants) (All versions), SIMATIC NET PC Software V14 (All versions < V14 SP1 Update 14), SIMATIC NET PC Software V15 (All versions), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions < V4.4.0), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions < V2.8.1), SIMATIC S7-1500 Software Controller (All versions < V20.8), SIMATIC S7-PLCSIM Advanced (All versions < V3.0), SIMATIC STEP 7 (TIA Portal) (All versions < V16), SIMATIC WinCC (TIA Portal) (All versions < V16), SIMATIC WinCC OA (All versions < V3.16 P013), SIMATIC WinCC Runtime Advanced (All versions < V16), SIMATIC WinCC Runtime Professional (All versions < V16), TIM 1531 IRC (incl. SIPLUS NET variants) (All versions < V2.1). Affected devices contain a message protection bypass vulnerability due to certain properties in the calculation used for integrity protection. This could allow an attacker in a Man-in-the-Middle position to modify network traffic sent on port 102/tcp to the affected devices.",Siemens,"Simatic Cp 1626,Simatic Et 200sp Open Controller Cpu 1515sp Pc (incl. Siplus Variants),Simatic Et 200sp Open Controller Cpu 1515sp Pc2 (incl. Siplus Variants),Simatic Hmi Panel (incl. Siplus Variants),Simatic Net Pc Software V14,Simatic Net Pc Software V15,Simatic S7-1200 Cpu Family (incl. Siplus Variants),Simatic S7-1500 Cpu Family (incl. Related Et200 Cpus And Siplus Variants),Simatic S7-1500 Software Controller,Simatic S7-plcsim Advanced,Simatic Step 7 (tia Portal),Simatic Wincc (tia Portal),Simatic Wincc Oa,Simatic Wincc Runtime Advanced,Simatic Wincc Runtime Professional,Tim 1531 Irc (incl. Siplus Net Variants)",5.9,MEDIUM,0.002360000042244792,false,,false,false,false,,false,false,2019-08-13T18:55:57.000Z,0 CVE-2019-10935,https://securityvulnerability.io/vulnerability/CVE-2019-10935,,"A vulnerability has been identified in SIMATIC PCS 7 V8.0 and earlier (All versions), SIMATIC PCS 7 V8.1 (All versions < V8.1 with WinCC V7.3 Upd 19), SIMATIC PCS 7 V8.2 (All versions < V8.2 SP1 with WinCC V7.4 SP1 Upd 11), SIMATIC PCS 7 V9.0 (All versions < V9.0 SP2 with WinCC V7.4 SP1 Upd11), SIMATIC WinCC Professional (TIA Portal V13) (All versions), SIMATIC WinCC Professional (TIA Portal V14) (All versions < V14 SP1 Upd 9), SIMATIC WinCC Professional (TIA Portal V15) (All versions < V15.1 Upd 3), SIMATIC WinCC Runtime Professional V13 (All versions), SIMATIC WinCC Runtime Professional V14 (All versions < V14.1 Upd 8), SIMATIC WinCC Runtime Professional V15 (All versions < V15.1 Upd 3), SIMATIC WinCC V7.2 and earlier (All versions), SIMATIC WinCC V7.3 (All versions < V7.3 Upd 19), SIMATIC WinCC V7.4 (All versions < V7.4 SP1 Upd 11), SIMATIC WinCC V7.5 (All versions < V7.5 Upd 3). The SIMATIC WinCC DataMonitor web application of the affected products allows to upload arbitrary ASPX code. The security vulnerability could be exploited by an authenticated attacker with network access to the WinCC DataMonitor application. No user interaction is required to exploit this vulnerability. The vulnerability impacts confidentiality, integrity, and availability of the affected device. At the stage of publishing this security advisory no public exploitation is known.",Siemens Ag,"Simatic Pcs 7 V8.0 And Earlier,Simatic Pcs 7 V8.1,Simatic Pcs 7 V8.2,Simatic Pcs 7 V9.0,Simatic Wincc Professional (tia Portal V13),Simatic Wincc Professional (tia Portal V14),Simatic Wincc Professional (tia Portal V15),Simatic Wincc Runtime Professional V13,Simatic Wincc Runtime Professional V14,Simatic Wincc Runtime Professional V15,Simatic Wincc V7.2 And Earlier,Simatic Wincc V7.3,Simatic Wincc V7.4,Simatic Wincc V7.5",7.2,HIGH,0.0009200000204145908,false,,false,false,false,,false,false,2019-07-11T21:17:47.000Z,0 CVE-2019-10917,https://securityvulnerability.io/vulnerability/CVE-2019-10917,,"A vulnerability has been identified in SIMATIC PCS 7 V8.0 and earlier (All versions), SIMATIC PCS 7 V8.1 (All versions < V8.1 with WinCC V7.3 Upd 19), SIMATIC PCS 7 V8.2 (All versions < V8.2 SP1 with WinCC V7.4 SP1 Upd11), SIMATIC PCS 7 V9.0 (All versions < V9.0 SP2 with WinCC V7.4 SP1 Upd11), SIMATIC WinCC (TIA Portal) V13 (All versions), SIMATIC WinCC (TIA Portal) V14 (All versions < V14 SP1 Upd 9), SIMATIC WinCC (TIA Portal) V15 (All versions < V15.1 Upd 3), SIMATIC WinCC Runtime Professional V13 (All versions), SIMATIC WinCC Runtime Professional V14 (All versions < V14.1 Upd 8), SIMATIC WinCC Runtime Professional V15 (All versions < V15.1 Upd 3), SIMATIC WinCC V7.2 and earlier (All versions), SIMATIC WinCC V7.3 (All versions < V7.3 Upd 19), SIMATIC WinCC V7.4 (All versions < V7.4 SP1 Upd 11), SIMATIC WinCC V7.5 (All versions < V7.5 Upd 3). An attacker with local access to the project file could cause a Denial-of-Service condition on the affected product while the project file is loaded. Successful exploitation requires access to the project file. An attacker could use the vulnerability to compromise availability of the affected system. At the time of advisory publication no public exploitation of this security vulnerability was known.",Siemens Ag,"Simatic Pcs 7 V8.0 And Earlier,Simatic Pcs 7 V8.1,Simatic Pcs 7 V8.2,Simatic Pcs 7 V9.0,Simatic Wincc (tia Portal) V13,Simatic Wincc (tia Portal) V14,Simatic Wincc (tia Portal) V15,Simatic Wincc Runtime Professional V13,Simatic Wincc Runtime Professional V14,Simatic Wincc Runtime Professional V15,Simatic Wincc V7.2 And Earlier,Simatic Wincc V7.3,Simatic Wincc V7.4,Simatic Wincc V7.5",5.5,MEDIUM,0.0004199999966658652,false,,false,false,false,,false,false,2019-05-14T19:54:48.000Z,0 CVE-2019-10916,https://securityvulnerability.io/vulnerability/CVE-2019-10916,,"A vulnerability has been identified in SIMATIC PCS 7 V8.0 and earlier (All versions), SIMATIC PCS 7 V8.1 (All versions < V8.1 with WinCC V7.3 Upd 19), SIMATIC PCS 7 V8.2 (All versions < V8.2 SP1 with WinCC V7.4 SP1 Upd11), SIMATIC PCS 7 V9.0 (All versions < V9.0 SP2 with WinCC V7.4 SP1 Upd11), SIMATIC WinCC (TIA Portal) V13 (All versions), SIMATIC WinCC (TIA Portal) V14 (All versions < V14 SP1 Upd 9), SIMATIC WinCC (TIA Portal) V15 (All versions < V15.1 Upd 3), SIMATIC WinCC Runtime Professional V13 (All versions), SIMATIC WinCC Runtime Professional V14 (All versions < V14.1 Upd 8), SIMATIC WinCC Runtime Professional V15 (All versions < V15.1 Upd 3), SIMATIC WinCC V7.2 and earlier (All versions), SIMATIC WinCC V7.3 (All versions < V7.3 Upd 19), SIMATIC WinCC V7.4 (All versions < V7.4 SP1 Upd 11), SIMATIC WinCC V7.5 (All versions < V7.5 Upd 3). An attacker with access to the project file could run arbitrary system commands with the privileges of the local database server. The vulnerability could be exploited by an attacker with access to the project file. The vulnerability does impact the confidentiality, integrity, and availability of the affected system. At the time of advisory publication no public exploitation of this security vulnerability was known.",Siemens Ag,"Simatic Pcs 7 V8.0 And Earlier,Simatic Pcs 7 V8.1,Simatic Pcs 7 V8.2,Simatic Pcs 7 V9.0,Simatic Wincc (tia Portal) V13,Simatic Wincc (tia Portal) V14,Simatic Wincc (tia Portal) V15,Simatic Wincc Runtime Professional V13,Simatic Wincc Runtime Professional V14,Simatic Wincc Runtime Professional V15,Simatic Wincc V7.2 And Earlier,Simatic Wincc V7.3,Simatic Wincc V7.4,Simatic Wincc V7.5",8.8,HIGH,0.0009699999936856329,false,,false,false,false,,false,false,2019-05-14T19:54:48.000Z,0 CVE-2019-10918,https://securityvulnerability.io/vulnerability/CVE-2019-10918,,"A vulnerability has been identified in SIMATIC PCS 7 V8.0 and earlier (All versions), SIMATIC PCS 7 V8.1 (All versions < V8.1 with WinCC V7.3 Upd 19), SIMATIC PCS 7 V8.2 (All versions < V8.2 SP1 with WinCC V7.4 SP1 Upd11), SIMATIC PCS 7 V9.0 (All versions < V9.0 SP2 with WinCC V7.4 SP1 Upd11), SIMATIC WinCC (TIA Portal) V13 (All versions), SIMATIC WinCC (TIA Portal) V14 (All versions < V14 SP1 Upd 9), SIMATIC WinCC (TIA Portal) V15 (All versions < V15.1 Upd 3), SIMATIC WinCC Runtime Professional V13 (All versions), SIMATIC WinCC Runtime Professional V14 (All versions < V14.1 Upd 8), SIMATIC WinCC Runtime Professional V15 (All versions < V15.1 Upd 3), SIMATIC WinCC V7.2 and earlier (All versions), SIMATIC WinCC V7.3 (All versions < V7.3 Upd 19), SIMATIC WinCC V7.4 (All versions < V7.4 SP1 Upd 11), SIMATIC WinCC V7.5 (All versions < V7.5 Upd 3). An authenticatd attacker with network access to the DCOM interface could execute arbitrary commands with SYSTEM privileges. The vulnerability could be exploited by an attacker with network access to the affected system. Successful exploitation requires authentication with a low-privileged user account and no user interaction. An attacker could use the vulnerability to compromise confidentiality and integrity and availability of the affected system. At the time of advisory publication no public exploitation of this security vulnerability was known.",Siemens Ag,"Simatic Pcs 7 V8.0 And Earlier,Simatic Pcs 7 V8.1,Simatic Pcs 7 V8.2,Simatic Pcs 7 V9.0,Simatic Wincc (tia Portal) V13,Simatic Wincc (tia Portal) V14,Simatic Wincc (tia Portal) V15,Simatic Wincc Runtime Professional V13,Simatic Wincc Runtime Professional V14,Simatic Wincc Runtime Professional V15,Simatic Wincc V7.2 And Earlier,Simatic Wincc V7.3,Simatic Wincc V7.4,Simatic Wincc V7.5",8.8,HIGH,0.0009500000160187483,false,,false,false,false,,false,false,2019-05-14T19:54:48.000Z,0 CVE-2019-6572,https://securityvulnerability.io/vulnerability/CVE-2019-6572,,"A vulnerability has been identified in SIMATIC HMI Comfort Panels 4"" - 22"" (All versions < V15.1 Update 1), SIMATIC HMI Comfort Outdoor Panels 7"" & 15"" (All versions < V15.1 Update 1), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 und KTP900F (All versions < V15.1 Update 1), SIMATIC WinCC Runtime Advanced (All versions < V15.1 Update 1), SIMATIC WinCC Runtime Professional (All versions < V15.1 Update 1), SIMATIC WinCC (TIA Portal) (All versions < V15.1 Update 1), SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel) (All versions). The affected device offered SNMP read and write capacities with a publicly know hardcoded community string. The security vulnerability could be exploited by an attacker with network access to the affected device. Successful exploitation requires no system privileges and no user interaction. An attacker could use the vulnerability to compromise confidentiality and integrity of the affected system. At the time of advisory publication no public exploitation of this security vulnerability was known.",Siemens,"Simatic Hmi Comfort Panels 4"" - 22"",Simatic Hmi Comfort Outdoor Panels 7"" & 15"",Simatic Hmi Ktp Mobile Panels Ktp400f, Ktp700, Ktp700f, Ktp900 Und Ktp900f,Simatic Wincc Runtime Advanced,Simatic Wincc Runtime Professional,Simatic Wincc (tia Portal),Simatic Hmi Classic Devices (tp/mp/op/mp Mobile Panel)",9.1,CRITICAL,0.003800000064074993,false,,false,false,false,,false,false,2019-05-14T19:54:48.000Z,0 CVE-2019-6577,https://securityvulnerability.io/vulnerability/CVE-2019-6577,,"A vulnerability has been identified in SIMATIC HMI Comfort Panels 4"" - 22"" (All versions < V15.1 Update 1), SIMATIC HMI Comfort Outdoor Panels 7"" & 15"" (All versions < V15.1 Update 1), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 und KTP900F (All versions < V15.1 Update 1), SIMATIC WinCC Runtime Advanced (All versions < V15.1 Update 1), SIMATIC WinCC Runtime Professional (All versions < V15.1 Update 1), SIMATIC WinCC (TIA Portal) (All versions < V15.1 Update 1), SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel) (All versions). The integrated web server could allow Cross-Site Scripting (XSS) attacks if an attacker is able to modify particular parts of the device configuration via SNMP. The security vulnerability could be exploited by an attacker with network access to the affected system. Successful exploitation requires system privileges and user interaction. An attacker could use the vulnerability to compromise confidentiality and the integrity of the affected system. At the stage of publishing this security advisory no public exploitation is known.",Siemens,"Simatic Hmi Comfort Panels 4"" - 22"",Simatic Hmi Comfort Outdoor Panels 7"" & 15"",Simatic Hmi Ktp Mobile Panels Ktp400f, Ktp700, Ktp700f, Ktp900 Und Ktp900f,Simatic Wincc Runtime Advanced,Simatic Wincc Runtime Professional,Simatic Wincc (tia Portal),Simatic Hmi Classic Devices (tp/mp/op/mp Mobile Panel)",5.4,MEDIUM,0.0006600000197067857,false,,false,false,false,,false,false,2019-05-14T19:54:48.000Z,0 CVE-2019-6576,https://securityvulnerability.io/vulnerability/CVE-2019-6576,,"A vulnerability has been identified in SIMATIC HMI Comfort Panels 4"" - 22"" (All versions < V15.1 Update 1), SIMATIC HMI Comfort Outdoor Panels 7"" & 15"" (All versions < V15.1 Update 1), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 und KTP900F (All versions < V15.1 Update 1), SIMATIC WinCC Runtime Advanced (All versions < V15.1 Update 1), SIMATIC WinCC Runtime Professional (All versions < V15.1 Update 1), SIMATIC WinCC (TIA Portal) (All versions < V15.1 Update 1), SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel) (All versions). An attacker with network access to affected devices could potentially obtain a TLS session key. If the attacker is able to observe TLS traffic between a legitimate user and the device, then the attacker could decrypt the TLS traffic. The security vulnerability could be exploited by an attacker who has network access to the web interface of the device and who is able to observe TLS traffic between legitimate users and the web interface of the affected device. The vulnerability could impact the confidentiality of the communication between the affected device and a legitimate user. At the time of advisory publication no public exploitation of the security vulnerability was known.",Siemens,"Simatic Hmi Comfort Panels 4"" - 22"",Simatic Hmi Comfort Outdoor Panels 7"" & 15"",Simatic Hmi Ktp Mobile Panels Ktp400f, Ktp700, Ktp700f, Ktp900 Und Ktp900f,Simatic Wincc Runtime Advanced,Simatic Wincc Runtime Professional,Simatic Wincc (tia Portal),Simatic Hmi Classic Devices (tp/mp/op/mp Mobile Panel)",7.5,HIGH,0.0013500000350177288,false,,false,false,false,,false,false,2019-05-14T19:54:48.000Z,0 CVE-2018-13812,https://securityvulnerability.io/vulnerability/CVE-2018-13812,,"A vulnerability has been identified in SIMATIC HMI Comfort Panels 4"" - 22"" (All versions < V15 Update 4), SIMATIC HMI Comfort Outdoor Panels 7"" & 15"" (All versions < V15 Update 4), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15 Update 4), SIMATIC WinCC Runtime Advanced (All versions < V15 Update 4), SIMATIC WinCC Runtime Professional (All versions < V15 Update 4), SIMATIC WinCC (TIA Portal) (All versions < V15 Update 4), SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel) (All versions). A directory traversal vulnerability could allow to download arbitrary files from the device. The security vulnerability could be exploited by an attacker with network access to the integrated web server. No user interaction and no authentication is required to exploit the vulnerability. The vulnerability impacts the confidentiality of the device. At the time of advisory publication no public exploitation of this security vulnerability was known.",Siemens,"Simatic Hmi Comfort Panels 4"" - 22"", Simatic Hmi Comfort Outdoor Panels 7"" & 15"", Simatic Hmi Ktp Mobile Panels Ktp400f, Ktp700, Ktp700f, Ktp900 Und Ktp900f, Simatic Wincc Runtime Advanced, Simatic Wincc Runtime Professional, Simatic Wincc (tia Portal), Simatic Hmi Classic Devices (tp/mp/op/mp Mobile Panel)",7.5,HIGH,0.0017500000540167093,false,,false,false,false,,false,false,2018-12-13T16:00:00.000Z,0 CVE-2018-13814,https://securityvulnerability.io/vulnerability/CVE-2018-13814,,"A vulnerability has been identified in SIMATIC HMI Comfort Panels 4"" - 22"" (All versions < V14), SIMATIC HMI Comfort Outdoor Panels 7"" & 15"" (All versions < V14), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V14), SIMATIC WinCC Runtime Advanced (All versions < V14), SIMATIC WinCC Runtime Professional (All versions < V14), SIMATIC WinCC (TIA Portal) (All versions < V14), SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel) (All versions). The integrated web server (port 80/tcp and port 443/tcp) of the affected devices could allow an attacker to inject HTTP headers. An attacker must trick a valid user who is authenticated to the device into clicking on a malicious link to exploit the vulnerability. At the time of advisory publication no public exploitation of this security vulnerability was known.",Siemens,"Simatic Hmi Comfort Panels 4"" - 22"", Simatic Hmi Comfort Outdoor Panels 7"" & 15"", Simatic Hmi Ktp Mobile Panels Ktp400f, Ktp700, Ktp700f, Ktp900 Und Ktp900f, Simatic Wincc Runtime Advanced, Simatic Wincc Runtime Professional, Simatic Wincc (tia Portal), Simatic Hmi Classic Devices (tp/mp/op/mp Mobile Panel)",8.8,HIGH,0.0020800000056624413,false,,false,false,false,,false,false,2018-12-13T16:00:00.000Z,0 CVE-2018-13813,https://securityvulnerability.io/vulnerability/CVE-2018-13813,,"A vulnerability has been identified in SIMATIC HMI Comfort Panels 4"" - 22"" (All versions < V15 Update 4), SIMATIC HMI Comfort Outdoor Panels 7"" & 15"" (All versions < V15 Update 4), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15 Update 4), SIMATIC WinCC Runtime Advanced (All versions < V15 Update 4), SIMATIC WinCC Runtime Professional (All versions < V15 Update 4), SIMATIC WinCC (TIA Portal) (All versions < V15 Update 4), SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel) (All versions). The webserver of affected HMI devices may allow URL redirections to untrusted websites. An attacker must trick a valid user who is authenticated to the device into clicking on a malicious link to exploit the vulnerability. At the time of advisory publication no public exploitation of this security vulnerability was known.",Siemens,"Simatic Hmi Comfort Panels 4"" - 22"", Simatic Hmi Comfort Outdoor Panels 7"" & 15"", Simatic Hmi Ktp Mobile Panels Ktp400f, Ktp700, Ktp700f, Ktp900 Und Ktp900f, Simatic Wincc Runtime Advanced, Simatic Wincc Runtime Professional, Simatic Wincc (tia Portal), Simatic Hmi Classic Devices (tp/mp/op/mp Mobile Panel)",8.1,HIGH,0.0015800000401213765,false,,false,false,false,,false,false,2018-12-13T16:00:00.000Z,0 CVE-2018-11453,https://securityvulnerability.io/vulnerability/CVE-2018-11453,,"A vulnerability has been identified in SIMATIC STEP 7 (TIA Portal) and WinCC (TIA Portal) V10, V11, V12 (All versions), SIMATIC STEP 7 (TIA Portal) and WinCC (TIA Portal) V13 (All versions < V13 SP2 Update 2), SIMATIC STEP 7 (TIA Portal) and WinCC (TIA Portal) V14 (All versions < V14 SP1 Update 6), SIMATIC STEP 7 (TIA Portal) and WinCC (TIA Portal) V15 (All versions < V15 Update 2). Improper file permissions in the default installation of TIA Portal may allow an attacker with local file system access to insert specially crafted files which may prevent TIA Portal startup (Denial-of-Service) or lead to local code execution. No special privileges are required, but the victim needs to attempt to start TIA Portal after the manipulation.",Siemens,"Simatic Step 7 (tia Portal) And Wincc (tia Portal) V10, V11, V12, Simatic Step 7 (tia Portal) And Wincc (tia Portal) V13, Simatic Step 7 (tia Portal) And Wincc (tia Portal) V14, Simatic Step 7 (tia Portal) And Wincc (tia Portal) V15",7.8,HIGH,0.0004900000058114529,false,,false,false,false,,false,false,2018-08-07T00:00:00.000Z,0 CVE-2018-11454,https://securityvulnerability.io/vulnerability/CVE-2018-11454,,"A vulnerability has been identified in SIMATIC STEP 7 (TIA Portal) and WinCC (TIA Portal) V10, V11, V12 (All versions), SIMATIC STEP 7 (TIA Portal) and WinCC (TIA Portal) V13 (All versions < V13 SP2 Update 2), SIMATIC STEP 7 (TIA Portal) and WinCC (TIA Portal) V14 (All versions < V14 SP1 Update 6), SIMATIC STEP 7 (TIA Portal) and WinCC (TIA Portal) V15 (All versions < V15 Update 2). Improper file permissions in the default installation of TIA Portal may allow an attacker with local file system access to manipulate resources which may be transferred to devices and executed there by a different user. No special privileges are required, but the victim needs to transfer the manipulated files to a device. Execution is caused on the target device rather than on the PG device.",Siemens,"Simatic Step 7 (tia Portal) And Wincc (tia Portal) V10, V11, V12, Simatic Step 7 (tia Portal) And Wincc (tia Portal) V13, Simatic Step 7 (tia Portal) And Wincc (tia Portal) V14, Simatic Step 7 (tia Portal) And Wincc (tia Portal) V15",8.6,HIGH,0.0006900000153109431,false,,false,false,false,,false,false,2018-08-07T00:00:00.000Z,0 CVE-2017-6865,https://securityvulnerability.io/vulnerability/CVE-2017-6865,,"A vulnerability has been identified in Primary Setup Tool (PST) (All versions < V4.2 HF1), SIMATIC Automation Tool (All versions < V3.0), SIMATIC NET PC-Software (All versions < V14 SP1), SIMATIC PCS 7 V8.1 (All versions), SIMATIC PCS 7 V8.2 (All versions < V8.2 SP1), SIMATIC STEP 7 (TIA Portal) V13 (All versions < V13 SP2), SIMATIC STEP 7 (TIA Portal) V14 (All versions < V14 SP1), SIMATIC STEP 7 V5.X (All versions < V5.6), SIMATIC WinAC RTX 2010 SP2 (All versions), SIMATIC WinAC RTX F 2010 SP2 (All versions), SIMATIC WinCC (TIA Portal) V13 (All versions < V13 SP2), SIMATIC WinCC (TIA Portal) V14 (All versions < V14 SP1), SIMATIC WinCC V7.2 and prior (All versions), SIMATIC WinCC V7.3 (All versions < V7.3 Update 15), SIMATIC WinCC V7.4 (All versions < V7.4 SP1 Upd1), SIMATIC WinCC flexible 2008 (All versions < flexible 2008 SP5), SINAUT ST7CC (All versions installed in conjunction with SIMATIC WinCC < V7.3 Update 15), SINEMA Server (All versions < V14), SINUMERIK 808D Programming Tool (All versions < V4.7 SP4 HF2), SMART PC Access (All versions < V2.3), STEP 7 - Micro/WIN SMART (All versions < V2.3), Security Configuration Tool (SCT) (All versions < V5.0). Specially crafted PROFINET DCP broadcast packets sent to the affected products on a local Ethernet segment (Layer 2) could cause a Denial-of-Service condition of some services. The services require manual restart to recover.",Siemens,"Primary Setup Tool (pst),Simatic Automation Tool,Simatic Net Pc-software,Simatic Pcs 7 V8.1,Simatic Pcs 7 V8.2,Simatic Step 7 (tia Portal) V13,Simatic Step 7 (tia Portal) V14,Simatic Step 7 V5.x,Simatic Winac Rtx 2010 Sp2,Simatic Winac Rtx F 2010 Sp2,Simatic Wincc (tia Portal) V13,Simatic Wincc (tia Portal) V14,Simatic Wincc V7.2 And Prior,Simatic Wincc V7.3,Simatic Wincc V7.4,Simatic Wincc Flexible 2008,Sinaut St7cc,Sinema Server,Sinumerik 808d Programming Tool,Smart Pc Access,Step 7 - Micro/win Smart,Security Configuration Tool (sct)",6.5,MEDIUM,0.0006799999973736703,false,,false,false,false,,false,false,2017-05-11T10:00:00.000Z,0 CVE-2016-7165,https://securityvulnerability.io/vulnerability/CVE-2016-7165,,"A vulnerability has been identified in Primary Setup Tool (PST) (All versions < V4.2 HF1), SIMATIC IT Production Suite (All versions < V7.0 SP1 HFX 2), SIMATIC NET PC-Software (All versions < V14), SIMATIC PCS 7 V7.1 (All versions), SIMATIC PCS 7 V8.0 (All versions), SIMATIC PCS 7 V8.1 (All versions), SIMATIC PCS 7 V8.2 (All versions < V8.2 SP1), SIMATIC STEP 7 (TIA Portal) V13 (All versions < V13 SP2), SIMATIC STEP 7 V5.X (All versions < V5.5 SP4 HF11), SIMATIC WinCC (TIA Portal) Basic, Comfort, Advanced (All versions < V14), SIMATIC WinCC (TIA Portal) Professional V13 (All versions < V13 SP2), SIMATIC WinCC (TIA Portal) Professional V14 (All versions < V14 SP1), SIMATIC WinCC Runtime Professional V13 (All versions < V13 SP2), SIMATIC WinCC Runtime Professional V14 (All versions < V14 SP1), SIMATIC WinCC V7.0 SP2 and earlier versions (All versions < V7.0 SP2 Upd 12), SIMATIC WinCC V7.0 SP3 (All versions < V7.0 SP3 Upd 8), SIMATIC WinCC V7.2 (All versions < V7.2 Upd 14), SIMATIC WinCC V7.3 (All versions < V7.3 Upd 11), SIMATIC WinCC V7.4 (All versions < V7.4 SP1), SIMIT V9.0 (All versions < V9.0 SP1), SINEMA Remote Connect Client (All versions < V1.0 SP3), SINEMA Server (All versions < V13 SP2), SOFTNET Security Client V5.0 (All versions), Security Configuration Tool (SCT) (All versions < V4.3 HF1), TeleControl Server Basic (All versions < V3.0 SP2), WinAC RTX 2010 SP2 (All versions), WinAC RTX F 2010 SP2 (All versions). Unquoted service paths could allow local Microsoft Windows operating system users to escalate their privileges if the affected products are not installed under their default path (""C:\Program Files\*"" or the localized equivalent).",Siemens,"Simatic Wincc,Simatic Wincc Runtime,Simatic Wincc \(tia Portal\),Simit,Simatic Pcs7,Simatic Step 7 \(tia Portal\),Simatic Pcs 7,Sinema Remote Connect,Simatic Step 7,Simatic Winac Rtx 2010,Softnet Security Client,Simatic Net Pc Software,Simatic It Production Suite,Telecontrol Basic,Security Configuration Tool,Primary Setup Tool,Sinema Server,Simatic Winac Rtx F 2010",6.4,MEDIUM,0.0006000000284984708,false,,false,false,false,,false,false,2016-11-15T19:00:00.000Z,0 CVE-2013-0671,https://securityvulnerability.io/vulnerability/CVE-2013-0671,,Directory traversal vulnerability in Siemens WinCC (TIA Portal) 11 allows remote authenticated users to read HMI web-application source code and user-defined scripts via a crafted URL.,Siemens,Wincc Tia Portal,,,0.0013699999544769526,false,,false,false,false,,false,false,2013-03-21T14:55:00.000Z,0 CVE-2013-0670,https://securityvulnerability.io/vulnerability/CVE-2013-0670,,CRLF injection vulnerability in the HMI web application in Siemens WinCC (TIA Portal) 11 allows remote attackers to inject arbitrary HTTP headers and conduct HTTP response splitting attacks via a crafted URL.,Siemens,Wincc Tia Portal,,,0.001829999964684248,false,,false,false,false,,false,false,2013-03-21T14:55:00.000Z,0 CVE-2011-4515,https://securityvulnerability.io/vulnerability/CVE-2011-4515,,"Siemens WinCC (TIA Portal) 11 uses a reversible algorithm for storing HMI web-application passwords in world-readable and world-writable files, which allows local users to obtain sensitive information by leveraging (1) physical access or (2) Sm@rt Server access.",Siemens,Wincc Tia Portal,,,0.0005799999926239252,false,,false,false,false,,false,false,2013-03-21T14:55:00.000Z,0